Download presentation
Presentation is loading. Please wait.
Published byKorey Mudgett Modified over 9 years ago
1
HOW TO MAKE TEST STRIPS AND ENLARGEMENTS IN THE MGJH COMMUNICATION TECHNOLOGIES DARKROOM
2
THIS IS AN ENLARGER It is used to make photographic prints (enlargements) from negatives
3
THESE ARE NEGATIVE CARRIERS They are used to hold negatives in the enlarger
4
THE NEGATIVE IS PLACED IN THE CARRIER WITH THE EMULSION (dull side) DOWN It is also best to place the negative upside down in the carrier so the image is oriented correctly to the person using the enlarger
5
PLACE THE NEGATIVE AND CARRIER BACK INTO THE ENLARGER
6
TURN ON THE FOCUSING SWITCH ON THE TIMER
7
OPEN THE APERATURE ON THE ENLARGER LENS SO THE MAXIMUM AMOUNT OF LIGHT CAN PASS THROUGH IT
8
ADJUST AND FOCUS THE ENLARGER AS YOU COMPOSE YOUR IMAGE
9
TURN THE APERATURE ON THE ENLARGER LENS DOWN TWO TO THREE STOPS This reduces the amount of light passing through the negative and lens so your image will have proper contrast
10
TURN OFF THE FOCUSING SWITCH ON THE TIMER
11
THIS IS A TEST STRIP A test strip is a narrow piece of photographic paper which is used to help you determine the correct exposure time for your photographic enlargement.
12
TEST STRIP CARD It is used with a test strip to help you determine the correct exposure time for your photographic enlargement. This is a
13
THE TIMER IS USED TO CONTROL THE AMOUNT OF LIGHT USED WHEN MAKING TEST STRIPS AND ENLARGEMENTS
14
PLACE THE TEST STRIP IN THE EASEL (EMULSION UP) AND COVER ALL EXCEPT THE FIRST FIFTH OF IT WITH THE TEST STRIP CARD Remember, the EMULSION OF THE PAPER is shiny!
15
It is used to time units of light that are projected toward the photographic paper. The timer is started by pushing this button
16
THE NEXT FIVE SLIDES SIMULATE WHAT IS DONE TO MAKE A TEST STRIP
17
TEST STRIP CARD PUSH TIMER BUTTON ONCE
18
TEST STRIP CARD PUSH TIMER BUTTON ONCE
19
TEST STRIP CARD PUSH TIMER BUTTON ONCE
20
TEST STRIP CARD PUSH TIMER BUTTON ONCE
21
TEST STRIP CARD COMPLETELY REMOVED
22
How many units of light have hit this section of the test strip? 1234 5
23
DEVELOP THE TEST STRIP DEVELOPER (2 MINUTES) STOP BATH (30 SECONDS) FIXER (2 MINUTES) WATER WASH (5 MINUTES IF YOU WANT TO KEEP IT). If not, a quick rinse is all that is needed. MINUMUM AGITATION (moving photo paper in solutions) NEEDS TO TAKE PLACE IN ALL TRAYS
24
Which section of this test strip looks good?
25
MAKE SURE THE ENLARGER SETTINGS DO NOT CHANGE OR EASEL BE MOVED BETWEEN THE DEVELOPMENT OF YOUR TEST STRIP AND THE EXPOSURE OF YOUR ENLARGMENT
26
PLACE A PIECE OF PHOTO PAPER IN THE EASEL (EMULSION UP) Remember, the EMULSION OF THE PAPER is shiny! AND……..
27
………..PUSH THE TIMER BUTTON THE REQUIRED NUMBER OF UNITS OF LIGHT REQUIRED
28
DEVELOP THE ENLARGEMENT DEVELOPER (2 MINUTES) STOP BATH (30 SECONDS) FIXER (2 MINUTES) WATER WASH (5 MINUTES) MINUMUM AGITATION (moving photo paper in solutions) NEEDS TO TAKE PLACE IN ALL 4 TRAYS
29
Your photo enlargement
30
Which section of this test strip looks good?
31
Your photo enlargement
32
Which section of this test strip looks good?
33
Your photo enlargement
34
EACH NEGATIVE THAT YOU ARE MAKING AN ENLARGEMENT FOR NEEDS TO HAVE THIS PROCEDURE DONE EVERY TIME. Allow 15 minutes to make one test strip and enlargement from a single negative. Only one test strip is needed (providing conditions do not change) if you plan to make more than one enlargement from the same negative.
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.