© Schenck Process GmbH 2006 Seite 1 NEW LOADING AUTOMATION SYSTEM LOGIX.NET Jose Ignacio Díaz de Villafranca y Gerardo Huerta Industrias Schenck S.A.

Similar presentations


Presentation on theme: "© Schenck Process GmbH 2006 Seite 1 NEW LOADING AUTOMATION SYSTEM LOGIX.NET Jose Ignacio Díaz de Villafranca y Gerardo Huerta Industrias Schenck S.A."— Presentation transcript:

1 © Schenck Process GmbH 2006 Seite 1 NEW LOADING AUTOMATION SYSTEM LOGIX.NET Jose Ignacio Díaz de Villafranca y Gerardo Huerta Industrias Schenck S.A.

2 © Industrias Schenck S.A. 2006 Hoja 2 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO The origin: global scale data handling Evolution of the Information Technologies New languages:.net-Microsoft y Java-Sun Growing success of Industrial Ethernet Industrial against other field buses. New hardware technology (Disobox)

3 © Industrias Schenck S.A. 2006 Hoja 3 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO Classical map of industrial communications

4 © Industrias Schenck S.A. 2006 Hoja 4 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO Classical map of industrial communications

5 © Industrias Schenck S.A. 2006 Hoja 5 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO TCP/IP Classical map of industrial communications

6 © Industrias Schenck S.A. 2006 Hoja 6 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO Ethernet has a great problem… a lack of determinism

7 © Industrias Schenck S.A. 2006 Hoja 7 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO The problem has been solved with IEEE1588 Allows to sincronize the internal at both extremes of the link. The most accurate clock is selected. Only valid for connection from point to point. All the intercommunication hardware must fulfill IEEE1588.

8 © Industrias Schenck S.A. 2006 Hoja 8 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO A clear request: to be modular

9 © Industrias Schenck S.A. 2006 Hoja 9 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO Other fundamental requests: The data base must be stable. The data should be shared with other applications. The data should be exported to other data bases. The data should be exported to other formats (Excel, pdf,…). The data should be accessible from the net. Flexibility: the system must support different configurations.

10 © Industrias Schenck S.A. 2006 Hoja 10 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO New Communications → New Hardware DISOBOX

11 © Industrias Schenck S.A. 2006 Hoja 11 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO DISOBOX Use of rough analog load cells Corner adjustment easier Monitoring of every load cell Communication Ethernet TCP/IP Fast measurement ( > 100 m/s ) Load cell exchange without recalibration Legal for trade OIML Easy retrofitting of scales New Communications → New Hardware

12 © Industrias Schenck S.A. 2006 Hoja 12 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO Typical Lay-Out of Instruments

13 © Industrias Schenck S.A. 2006 Hoja 13 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO Main characteristics Specially designed to work in network. Robust and concurrent data base (SQL). Access to the data management by a simple web navegator from any computer of the corporate network. Transit control of the entrance and exit of materials. Expedition of products fed under weigher. Management of own fleet and customary vehicles. Prepared for the use of inductive cards. Connection from the system to all the plant’s weighers. Possibility of managing the barriers or traffic lights at the entrance and exit of each weigher. Carrying out of multiple petitions of the programs in various computers. Languages: spanish, english, portuguese and defined by the user.

14 © Industrias Schenck S.A. 2006 Hoja 14 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO Typical screen lay-out

15 © Industrias Schenck S.A. 2006 Hoja 15 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO Web characteristics The data management module of the system is in fact an Internet server which permits to visualize, modify and print the system’s data through the web navegator. Any corporate computer serves for the data management without having to install additional software. It possesses access control for the users of the different security levels and remote access through Internet is also possible.

16 © Industrias Schenck S.A. 2006 Hoja 16 VI COLOQUIOS PARA DIRECTORES Y TÉCNICOS DE FABRICAS DE CEMENTO Conclusions Growing expansion of Ethernet for Industrial Communications. Net architecture must fulfil IEEE 1558. Filed instruments must be of the web-generation and have high compatibility with existing systems (DISOBOX). New perspectives for remote maintenance are open. The program environment must create web applications (LOGIX). Net operative decentralized and with simultaneous running programs.

17 © Schenck Process GmbH 2006 Seite 17 NEW LOADING AUTOMATION SYSTEM LOGIX.NET Jose Ignacio Díaz de Villafranca y Gerardo Huerta Industrias Schenck S.A.