Download presentation
Presentation is loading. Please wait.
Published byKenzie Motte Modified over 9 years ago
1
constant strain rate constant stress (creep) Deformation tests ( constant T )
2
Constant strain rate testing + Extensometer INSTRON 2630-014 (g.l. 10 mm, range 50 %) At our lab: Electromechanical (Instron 1123 or 5567) Universal Electromechanical Testing Machine Instron 5567 (dual column table top, 30 kN) Temperature Chamber Instron 3119 (-70 °C / 250 °C ) Servohydraulic Testing Machines (MTS 810)
3
Constant strain rate behaviour
4
... details at T = 573 K (Th > 0.6 ! For the Al-alloy) … why not constant loading-rate experiment?
5
Creep Testing: top-lever machine
6
PP P 10 mm initial stateafter creep Compression Test Compression Cage
7
Creep behaviour
8
The Monkman-Grant Relationship for time to fracture : time to fracture : minimum creep rate or, more general:where: 0.77<m<0.93; 0.48<B MG <1.3 for Al, Cu, Ti, Fe and Ni base alloys (from Monkman-Grant research) Test of Monkman-Grant for Cu
9
Engineering Estimates of Creep Behaviour Larson-Miller parameter (LM) ksi Fig a