Datasheet System Conquest 6_17.12.11_01 1/9 CONQUEST 6 Electronic control system for whirlpool Product datasheet VALANTIS SARL CH – 2610 ST-IMIER
2
2/9 Features ON/OFF blower ON/OFF pump Manual blower power control (+/-) Variation of blower flow (wave effect) Interval pumpWater level control Spot light or RGB light (chromotherapy) Concept Disinfection mode (drying) Safety rules IMPORTANT Follow the directions for installation and connection of the control box. This one is not suitable for medical use. a) The box must be located in a dry and clean area with good ventilation and installed at least 3 centimers above the ground floor. b) Make sure that there are no unconnected wires inside the control box. c) Keep at least 2 centimeters between low and high power cables. d) All electrical parts must be mounted in a such way that they cannot fall down into the whirlpool. e) It is highly recommended to contact a state-registered electrician for installation. Valantis declines all responsability for consequences of damages caused by the device. f) Temperature ranges : storage -20 to 60°C, operating 0 to 45°C. g) It is not recommended to put on stress the system over an normal use. A security stops it automatically if any activity is detected after 20 minutes. h) On the main entry of the electrical installation, a fuse (FI) corresponding at least to the sum of the power supply of the device must be installed We reserve the right to change the product and specification without notice. VALANTIS SARL CH – 2610 ST-IMIER Water level Controller Newjac 8 Blower Spot Chromo 1 Panel Conquest 6 Driver Chromo 2 Spot Chromo 2 Pump Spot Interval blower Rincing mode (flush) Rincing valve or chemical disinfection Datasheet System Conquest 6_17.12.11_01 Water heater Chemical Disinfection
3
3/9 Components Plastic enclosure 45x30x15mm 1 LED indicator Adjustable by trimmer Cable length 1800 mm. IP65 ROHS Water level sensor « TLS1 » Code 0010137600 VALANTIS SARL CH – 2610 ST-IMIER Panel Conquest 6 Code VPF09026X1 Non-contractual picture Datasheet System Conquest 6_17.12.11_01 Oblong shape plastic enclosure 174 x 30 mm Chrome coated enclosure. Membrane foil front panel 6 buttons 2 LED’s indicator Cable length 2000 mm. IP65 / ROHS Controller Newjac 8 Code VPF07002C1 Control box 230V 50/60 Hz 16A 2 variable outputs (triacs) 3 ON/OFF outputs (relays) Plastic enclosure 200x155x80 mm Fit out with - 4 cable glands PE M16 for cable 5-10 mm. - 3 grommets (shutters) M16 IP56 ROHS Non-contractual picture
4
4/9 Components 2/2 Driver Chromo 2 Code VPF10030A1 Plastic enclosure 130 x 90 x 55 mm 2 inputs for RGB spot light Fit out with : - 1 x PE M16 for cable diam. 5-10 mm - 1 x grommet (shutters) M16 - IP56 / ROHS VALANTIS SARL CH – 2610 ST-IMIER Spot Chromo Code VPF10031A1 Chrome coated enclosure diam. 55 mm Thickness 1.5 mm 8 colours (white, red, orange, yellow, green, blue, indigo, purple) Cable length 2000 mm. with PE M16 + nut IP65 / ROHS Non-contractual picture Datasheet System Conquest 6_17.12.11_01
5
5/9 Control box connection Specification Rated voltage :230V, 50/60Hz, 1 phase Rated power :3680W Rated current :16A Maximum load Water heater: 230V, 9A, 2070W Spot :230V, 9A, 2070W Rincing valve or chemical disinfection:230V, 9A, 2070W Pump :230V, 6A, 1380W Blower :230V, 6A, 1380W The sum of the loads must not exceed rated power and current VALANTIS SARL CH – 2610 ST-IMIER Datasheet System Conquest 6_17.12.11_01 Power Supply 230 V Panel Conquest 6 Code VPF08012X1 5V Water level sensor TLS1 Code 0010137600 5V Spot 230V Pump 230V + = white SD = brown - = green + - SD Rincing valve 230V or Chemical disinfection 230V Water Heater 230 V Blower 230V
6
6/9 Recommended connection with RGB spot light VALANTIS SARL CH – 2610 ST-IMIER IMPORTANT : 5V cables (panel, temperature and water level sensor) must not cross power areas of the electronic board. Outside the enclosure, it is highly recommended to separate cabling of 230V and 5V cables. Datasheet System Conquest 6_17.12.11_01
7
1.ON/OFF spot or RGB spot light 2.ON/OFF pump / Interval pump/ Water heater / Disinfection (option) 3.Variation blower / Interval blower 4.ON/OFF blower 5.+ blower 6.- blower 7.LED pump 8.LED blower VALANTIS SARL CH – 2610 ST-IMIER 1 23 4 5 7 6 8 User manual 1/2 Datasheet System Conquest 6_17.12.11_01 7/9
8
VALANTIS SARL CH – 2610 ST-IMIER User manual 2/2 Datasheet System Conquest 6_17.12.11_01 8/9
9
VALANTIS SARL CH – 2610 ST-IMIER Programs The panel contains several programs whose can be selected by a code. The following programs are available : ProgramNr.Description ST6A1Panel Conquest 6A without disinfection ST6AT2Panel Conquest 6A with progressive drying disinfection ST6E3Panel Conquest 6E without disinfection ST6R4Panel Conquest 6E with rincing disinfection ST5Panel Conquest 6 without disinfection STAT6Panel Conquest 6 with progressive drying disinfection STET *7Panel Conquest 6 with rincing + progressive drying desinfection TST8Test (Valantis internal use only) Re-programming instructions : Switch on the system with water into the whirlpool. Within 2 min., drain the whirlpool until the TLS don’t detect water anymore (LEDs blink each 5 sec.). Press buttons 0 1 2 0 1 during an interval of maximum 2 min. LEDs blink 8 times per sequence. Button 0 = select program. Observe corresponding LED sequence blinking as per a.m. program nr. Button 1 = save selected program. Button 2 = cancel the selection. Return to the previous program. * Ex-factory setting Datasheet System Conquest 6_17.12.11_01 012 9/9