Download presentation
Presentation is loading. Please wait.
Published byJarrett Huish Modified over 9 years ago
1
Measuring Livestock Odors Dr. Ron E. Sheffield LSU AgCenter rsheffield@agcenter.lsu.edu 225.205.4533
2
Olfaction -- Sense of Smell Complex Evokes a physiological and emotional reaction Humans detect > 10,000 odors Manure over 150 odorous compounds Mixture of gases Extremely low concentrations Health impacts?
3
Gas vs Odor Measurement Gas Identify individual gases Measure concentrations Odor--Olfactometry Analyze mixture Correlates with odor Uses human sense of smell
4
Odor Measurement and Description Intensity (strength) Duration / Persistence Frequency Offensiveness / Hedonic tone Character descriptor Threshold concentrations (D/T) Detection Recognition
5
Odor TestDefinitionAnalytical Method(s) Intensity (strength) Strength of an odor sample above the detection threshold. N-butanol Duration / Persistence Measure of how easily the odor can be diluted in air: Full strength intensity divided by threshold concentration. N-butanol and D/T d Frequency Return interval (hours, days) of a detected odor. No analytical measure. Offensiveness / Hedonic tone Measure of unpleasantness of an odor. Typically displayed as a scale: -10 (unpleasant) to +10 (pleasant). Odor Panel Character descriptor Description of an odor. Trained panelists use standardized terms such as sulfide, rancid, putrid, or phenolic. Odor Panel Threshold Concentration (D/T d ) - Detection Volume of non-odorous air needed to dilute a unit volume of air to the point where panelist begin to detect an odor. Olfactometry; field olfactometer (scentometer) Threshold Concentration (D/T r ) - Recognition Volume of non-odorous air needed to dilute a unit volume of air to the point where panelist begin to recognize an odor. D/T r >/= D/T d Olfactometery
6
Odor -- Sound Analogy Odor... Sound Below Detection... “I can’t hear it” Detection... “I hear something” Recognition... “It’s Elvis!” Intensity... “How loud is it?”
7
Odor Intensity Measurement Table 2. Odor Intensity Reference Scale Based on N - Butanol Intensity category Equivalent head space concentration of N - butanol in air (ppm)* Mixture of N - butanol in water (ppm) 0 No odor 00 1 Very Light 25250 2 Light 75750 3 Moderate 225 2250 4 Strong 6756750 5 Very strong 202520250 * Based on air temperature of 20.3 ° C
8
Duration / Persistence Intensity 0 10 Log Concentration (D/T) Decreasing
9
Character Descriptor Smells like Mint – Musty Earth– Rotten Mold – Sewer Sulfur – Sour Ammonia – Pungent Menthol – Burned
11
Odor Measurement Electronic nose Correlates gases to odors Similar to indicator gas No accepted tool for manure odors Olfactometer Measures concentration ASTM & European Standard Scentometer
12
Triangular Forced Choice Olfactometer Dynamic Triangular Forced choice Standardized procedures ASTM European Standard Trained panelists
13
Box Scentometer
14
Facial Mask Field Olfactometer
15
Nasal Ranger Field Olfactometer IdaNose
16
Fenceline H 2 S Monitoring Jerome 860 0.1 – 10 ppm OdaLog-LR 0.01 – 2 ppm
17
Odor Modeling Correlate mathematical representations to the measured effect during real world situations. Used for technology evaluation and planning Not intended for regulatory enforcement Currently no “ag odor” model incorporates real-world terrain features Field Sniffers Model Comparison
18
Field Sniffers Trained panelists Measurements N-butanol intensity scale Scentometers Field olfactometers Charcoal filter masks Record intensity Validate dispersion model
19
Field Sniffers 100 Meters Weather Station Wind Direction 50 Meters 5 - 20 Meters 200 Meters
20
Odor Methods Study Evaluate the differences of odor concentrations determined by the three field olfactometers using trained panelists Variability between field olfactometers Correlation to field and laboratory measured odor intensity (n-butanol) Correlation to laboratory olfactometry panel Correlation to field and laboratory gas analysis
21
Experimental Design Control Laboratory olfactometry Treatments Box scentometer Facial mask field olfactometer “Nasal Ranger” field olfactometer Field n-butanol Laboratory n-butanol Jerome Meter (H 2 S/TRS) Ammonia GC/MS & GC/SPME
22
TRS/H 2 S (mg/l) NH 3 (mg/l) Food Processor 0.0700.008 WWPS0.0020.039 Dairy Freestall1.1800.208 Open-Lot Dairy 1.1500.033 Feedlot1.4600.019
23
Standard Deviation of logD/T Food Processor WWPSOpen-Lot Dairy Freestall Dairy
24
Standard Deviation of Intensity
25
Emissions from Livestock Farms Methodology 38 dairy and 15 beef feeding operations August, 2003 and the April, 2004 Three measurements Summer (August & September) Fall (October & November) Spring (April) “Blind” data set Trained panelists – subset of panelists from Phase 1
26
Openlot Dairies
27
Corral Cleaning
28
Freestall Dairy
29
Calf Hutches
30
Heifer Facility
31
Average Dairy Odor Emissions LocationDistanceDetection Threshold Odor Intensity H 2 S/TRSNH 3 Range - unitsmeters( 1.4 – 60 )( 0 – 6 )ppm Openlot Dairies <1,000 hd Source11.42.80.0630.410 50 meters8.42.70.0380.420 200 meters3.11.50.0200.290 Openlot Dairies >1,000 hd Source17.03.70.0780.360 50 meters4.81.80.0420.270 200 meters4.51.90.0240.270 Scraped Freestall Dairies Source29.04.40.2230.530 50 meters13.43.30.1610.430 200 meters6.32.50.0780.260 Flushed Freestall Dairies Source22.24.20.3790.660 50 meters12.43.30.1730.430 200 meters8.52.80.1170.300
32
Average Feedlot Odor Emissions LocationDistanceDetection Threshold Odor Intensity H 2 S/TRSNH 3 Range - unitsmeters( 1.4 – 60 )( 0 – 6 )ppm Calf Hutches Source6.61.40.0070.125 50 meters- 200 meters- Heifer Pens Source29.13.80.0610.050 50 meters- 200 meters- Feedlots Source16.33.20.0190.185 50 meters11.02.40.0120.086 200 meters5.91.80.0060.000 Feedlot + Heifer Pens Source17.63.30.0220.177 50 meters- 200 meters-
33
Variability within Farm Groups
34
Seasonal Variability - Source
35
Seasonal Variability – 200m
36
Compost – Static Compost – Turning of Fresh Manure Compost - Turning Corn Silage Bunker Corral Cleaning Slurry - Fresh/Vacuumed Manure Broadcast Application Solid Manure - Corral Manure Application Pivot Irrigation – Drag Tube @100% Manure Pivot Irrigation – Spray Nozzles @100% Manure Pivot Irrigation – Rotating Nozzles @100% Manure Pivot Irrigation – “Wobble” Nozzles @100% Manure Separated Solids Broadcast Application Settling Basin Settling Basin – covered Land Application and Manure Management Practices
37
Slurry Manure Application
38
Solid Manure Application
39
Solid & Slurry Manure Application PracticeDistanceDetection Threshold Odor Intensity H 2 S/TRSNH 3 Range - unitsmeters( 1.4 – 60 )( 0 – 6 )ppm Dry Corral Manure7510.43.40.0874.00 maximum21.26.00.0874.00 Dry Corral Manure10023.44.20.0090.05 maximum42.46.00.0100.10 Settled Dairy Solids709.33.20.0440.50 maximum42.45.00.0610.75 Vacuumed Manure Slurry 10011.83.20.0310.83 maximum42.45.00.0461.2
40
Wastewater Irrigation Sprinklers Impact Sprinklers Drop Nozzles Sprays Rotating Heads
41
Nelson R3000 Rotator Nelson S3000 Spinner Senninger I-Wob
42
Wastewater Irrigation - Drag Hose
43
PracticeDistanceDetection Threshold Odor Intensity H 2 S/TRSNH 3 Range - unitsmeters( 1.4 – 60 )( 0 – 6 )ppm Drag Tube10015.23.50.0580.00 maximum42.45.00.0050.000 “Rotator” Nozzles 10026.54.6----0.13 maximum60.05.0----0.25 “Spray” Nozzles15012.54.80.2220.28 maximum60.06.00.2950.30 “Wobbler” Nozzles 10024.14.90.0790.30 maximum42.46.00.0850.35 Liquid Effluent Land Application
44
Odor Acceptability Is the odor present acceptable ………. ( -10 ”Unacceptable” … 0 … 10 “great”) as an odor on the farm property? _________ as an odor across the property line? _________ as an odor at a rural residence? _________ as an odor at a public event or private party? _________
45
Unacceptable Odors (</= -5)
46
Buffer Requirements Most buffers are targeted on odors (even when states only have authority to minimize risk to water) New or expanding construction Distances vary greatly between areas Most based on arbitrary distances rather than scientific procedures to reduce occurrence
47
OFFSET: Odor From Feedlots Setback Estimation Tool Scientific process to establish odor based setbacks Developed by Univ. of Minnesota, adopted by MN and MI Develops an Odor Emission Factor for all existing and proposed facilities Values shown are for Midwestern (IA, MN, MI) conditions, and assumes flat terrain
48
Odor Emission Factor Odor Emission Number x Area (sq.ft) x Odor Control Factor 10,000 Odor Emission Number x Area (sq.ft) x Odor Control Factor 10,000 Odor Emission Number x Area (sq.ft) x Odor Control Factor 10,000 Determine Odor Emission Factor for each odor source on the farm Barns Manure Storage/Stockpiles Feed Storage
49
Odor Emission Numbers Beef: dirt/concrete lot; freestall, scrape 4/ft 2 Dairy: Freestall deep pit; Loose housing, scrape 6/ft 2 Dairy: Tie stall, scrape 2/ft 2 Earthen manure basin: 1 st,2 nd cell 20,8/ft 2 Anaerobic Lagoon4/ft 2 Steel or concrete tank, above or below ground 28/ft 2 Crusted Stockpile2/ft 2 Values shown are for Midwestern (IA, MN, MI) conditions, and assumes flat terrain
50
Odor Control Factors No odor control technology 0 Biofilter on 100% for building exhaust fans 0.1 Geotextile cover (>2.4 mm) 0.5 Straw or natural crust on manure4-inches = 0.5 8-inches = 0.3 Impermeable cover 0.1 Values shown are for Midwestern (IA, MN, MI) conditions, and assumes flat terrain
51
Determining Setback Distances 7 hrs/mo 22 hrs/mo 29 hrs/mo 44 hrs/mo 66 hrs/mo 15 hrs/mo Suggested odor annoyance free frequencies 99% ~ cities w/population >5000, hospitals 98% ~ cities w/population <5000 97% ~ residential area w/ >50 homes, churches, parks 96% ~ residential area w/ <50 homes, churches 94% ~ < 5 rural homes 91% ~ < 2 rural homes Values shown are for Midwestern (IA, MN, MI) conditions, and assumes flat terrain
52
Measuring Livestock Odors
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.