Presentation is loading. Please wait.

Presentation is loading. Please wait.

CodeDataPlate.com. New in 2007 edition and in a-2008 2.7.5.2.1 MRL Pit Signage 3.18.6 Marking of HY Jack 8.10.2.2.2 Governor 8.10.4.1 Escalator Governor.

Similar presentations


Presentation on theme: "CodeDataPlate.com. New in 2007 edition and in a-2008 2.7.5.2.1 MRL Pit Signage 3.18.6 Marking of HY Jack 8.10.2.2.2 Governor 8.10.4.1 Escalator Governor."— Presentation transcript:

1 CodeDataPlate.com

2 New in 2007 edition and in a-2008 2.7.5.2.1 MRL Pit Signage 3.18.6 Marking of HY Jack 8.10.2.2.2 Governor 8.10.4.1 Escalator Governor 8.11 Requirements moved to 8.6 (‘08) 8.9.2 Added Esc. Code Data Plate Others in Parts 5, 6 and 7 Also changes for those enforcing NBCC (Canada)

3 CodeDataPlate.com Violations A17.1-2000 and later editions Part 8 A17.3-1996 and later editions

4 CodeDataPlate.com Data Plates A17.1 Requirements –Counterweight Runby Data Plate –Crosshead Data Plate –Capacity Plate –Safety Marking Plate –Jack Marking Plate –Rail Lube Plate –Governor Marking Plate –Brake Marking Plates –Buffer Marking Plate

5 CodeDataPlate.com More Data Plates A17.1 Requirements (Continued) –Plunger Gripper Marking Plate –Hydraulic Machine & Valve Data Plates –Escalator/Moving Walk Brake Data Plates –Chain Data Plates (Dumbwaiter) –Rack & Pinion Data Plate –Code Data Plate A17.3 Requirements –Rail Lube Plate –Capacity Plate

6 CodeDataPlate.com Tags A17.1 Tags –Governor Rope Tag –Hoist Rope Data Tag –Acceptance Safety Test Tag –Resocketing Tag –Escalator Governor –Periodic Test Tags A17.3 Tags –Hoist Rope Data Tag –Chain Data Tag

7 CodeDataPlate.com Signs A17.1 Signs –Bottom Car Clearances –Refuge Space on Top of Car Enclosure –Working Areas in the Car or on the Car Top –Working Areas in the Pit –Location of Equipment - Governor Servicing –Freight Car Signage –Anti-creep Operation –Fire Service Signage

8 CodeDataPlate.com More Signs A17.1 Signs (Continued) –Emergency Brake Sign –No Jumper Sign adjacent to Bypass Switches –Escalator & Moving Walk Caution Signs –Additional (Esc. & M.W.) Signs A17.3 Signs –Freight Car Signs –Escalator Caution Signs –D/W “No Riders” Signs

9 CodeDataPlate.com 2.4.5 Counterweight Runby Data Plate

10 CodeDataPlate.com 2.6.5.2 ( )

11 CodeDataPlate.com 2.13.4.2.4 Door Operator Plate Instructions Provided

12 CodeDataPlate.com 2.16.3.2.2 and 3.16.3 Under b-1995 and earlier Under 1996 and later A17.1 Req. 8.6.1.6.7 only not in A17.3 Hydro Traction

13 CodeDataPlate.com Jack, Safety Plank & Capacity Hydraulic (3.18.6) Traction (2.17.14) Marking of Hydraulic Jack The exposed portion of each hydraulic jack after installation shall be plainly marked in a permanent manner with the following: (a) the name or trademark by which the organization that manufactured the hydraulic jack can be identified (b) the manufacturer’s designation of the type or model (c) year of manufacture Marking Plates for Safeties A metal plate shall be securely attached to each safety so as to be readily visible, and shall be marked in a legible and permanent manner with letters and figures not less than 6 mm (0.25 in.) in height indicating: (a) the type of safety, based on 2.17.5 (b) the maximum tripping speed in m/s (ft/min) for which the safety is permitted (c) the maximum weight in kg (lb), that the safety is designed and installed to stop and sustain (d) the force in N (lbf) required to activate the safety or rope releasing carrier, if provided (e) the manufacturer’s name or trademark (07)

14 CodeDataPlate.com Other Hydraulic Markings

15 CodeDataPlate.com Safety Test Tag

16 CodeDataPlate.com Pull- thru + Buffer + Flex Hose Test Tag

17 CodeDataPlate.com For Roller Guides For Slide Guides A17.1 - 2.17.16 & A17.3 - 3.5.6 In A17.1-2000 and later editions this information must be on Crosshead Data Plate

18 CodeDataPlate.com 2.18.9 - Governor Plate

19 CodeDataPlate.com Brakes Plates 2.19.3.32.24.8.5 The emergency brake shall be provided with a marking plate indicating the range of total masses (car with attach- ments and its load) for which it is permitted to be used, the range of speeds at which it is set to operate, and the criteria such as rail lubrication requirements that are critical to the performance.

20 CodeDataPlate.com Buffer Marking Plates 2.22.3.3 8 items and 2.22.4.11 (for Oil Buffers) 2.22.2.3

21 CodeDataPlate.com 8.6.1.6.7 Check for any Missing or Damaged Signs and Data Plates Machine Room –Brake Plates –Governor Plate –Code Data Plate –Ambient Air Plate –Hydro Data Plates –Warning Signs Fire Service Signs Hoistway and Pit –Crosshead Data Plate –Rail Lube Instructions –Warning Signs –Safety Plank Plate –Buffer Plate –Counterweight Runby Freight & Capacity

22 CodeDataPlate.com Inspection Tags Acceptance Tests –8.10 Requirements –New Installations –Alterations Periodic –8.11 Requirements –8.11.1.6 Tag –New under b-2008: Testing moves to 8.6

23 CodeDataPlate.com TN 02-3392

24 CodeDataPlate.com TN 02-3392

25 CodeDataPlate.com

26

27

28

29

30

31 Code Data Plates 8.9.1 Required Information –8.10.1.2 Applicability of Inspection and Test Requirements 8.9.2 Location –Mainline or on Controller (07) – Additional Plate for External Escalator Inspections 8.9.3 Material and Construction –...shall remain permanently and readily legible.

32 CodeDataPlate.com SECTION 8.9 Requirement 8.9 contains requirements for all new and existing equipment within the Scope of this Code. 8.9.1 Required Information Data plate shall be provided and maintained that shall indicate the Code to be used for inspections and tests (see 8.10.1.2). The data plate shall indicate the Code and edition in effect at the time of installation. The data plate shall also indicate the Code in effect at the time of any alteration and indicate the applicable requirements of 8.7.

33 CodeDataPlate.com Installation Code Edition Original Installation Date –Elevator Permit Date –Other Dates If Unknown Original Installation Code –Follows AHJ’s Effective Dates –Use ASME Effective Dates AHJ has no dates No AHJ GSA –Format is the same as in Inspector’s Guide

34 CodeDataPlate.com Equipment Without Alteration Older Installations –Use applicable adopted A-17.1 editions –Use locally adopted code/standards such as: Adopted A17.3- Edition California CA Title 8 - Group 2 Ohio Bulletin 110 (Red Book) Iowa 875-IAC Ch. 73 Massachusetts 524 CMR Missouri 11 CSR 40-5.065 Pennsylvania PA 34 Ch. 7 Washington WAC 296-96 Min. Std. –Use building code referenced A17.1 edition New Installations –Use applicable ASME edition as AHJ adopts

35 CodeDataPlate.com Edition Sensitive Items (85 years of code) A17.3 applies from d-1986 through d-2000 to Part XII Item 1.6 Car Emergency Signal there are 6 differences Space Guards A17.1-1937 and later editions (also A17.3) Static Control a-1988 and later editions Glazing b-1989 and later editions & again in a-2005 Item 1.12/13 & 3.8 (Cab items) there are 16 differences and 16 more relating to car & hoistway doors & gates Door Restrictors b-1980, b-1983 and b-1989 differences Hydro RPR required for installations under c-1986 and later Fire Service b-1973, 1981, 1984, b-1989, 2000 and 2004

36 CodeDataPlate.com CDP Flow Chart

37 CodeDataPlate.com

38

39 Job Information Web, e-mail, phone or fax

40 CodeDataPlate.com Code Data Plate Order Form

41 CodeDataPlate.com Common Errors - Disconnect Change in Power Supply = 8.7.2.27.3 or 8.7.3.31.4 –Change of Voltage, Frequency or Number of Phases –Change from DC to AC –Change of combination of DC and AC Replace Wiring or Disconnect = 8.7.2.8 or 8.7.3.8 –Includes new machine room wiring, hoistway wiring and travelling cables –Requires conformance with Section 2.8 which includes reference to NFPA 70 (NEC)

42 CodeDataPlate.com Common Errors - Control 8.7.2.27 Install like Controller = 8.7.2.27.4 or 8.7.3.31.5 Change of Motion Ctrl. = 8.7.2.27.5 or 8.7.3.31.6 Change in Operation = 8.7.2.27.6 or 8.7.3.31.7 Related requirements –Top of Car Inspection = 8.7.2.27.1 or 8.7.3.31.1 –Leveling = 8.7.2.27.2 or 8.7.3.31.2 –Anti-creep = 8.7.3.31.3 –Stop Switch = 8.7.2.27.7 (was 8.7.2.14.5 in a-2002 and earlier) –Alter an EPD = 8.7.2.27.8 or 8.7.3.31.11 (‘07)

43 CodeDataPlate.com Common Errors - Jack 8.7.3.23 Replace Jack with new Jack = 8.7.3.23.1 Cut off head and weld onto new Cylinder, re-use the plunger = 8.7.3.23.3 Related requirements –Plunger only = 8.7.3.23.2 –Change of Working Pressure = 8.7.3.23.4 –Relocation of Jack = 8.7.3.23.5 –Relocation of Tank = 8.7.3.23.6 –Plunger Gripper = 8.7.3.23.7

44 CodeDataPlate.com Custom Software

45 CodeDataPlate.com Custom Software

46 CodeDataPlate.com Custom Plates Alterations Under A17.1-1996 Edition Alterations Under A17.1-2000 Edition

47 CodeDataPlate.com Alteration Plate Door Operator Wiring Re-opening Devise Door Restrictor Plunger Gripper Valve Tank Limits Top of Car Insp.. Leveling Controller Replacement Emergency Operations

48 CodeDataPlate.com Jack Replacement Re-opening Devise Door Restrictor Rope Brake Cylinder Only Cab Interiors Valve Alteration Emergency Lowering HY Fire Service Alterations TR Field Marked Alteration Plate Covers Common Minor Alterations Instructions Provided

49 CodeDataPlate.com Code Data Plate Kits

50 CodeDataPlate.com Thank You - Questions


Download ppt "CodeDataPlate.com. New in 2007 edition and in a-2008 2.7.5.2.1 MRL Pit Signage 3.18.6 Marking of HY Jack 8.10.2.2.2 Governor 8.10.4.1 Escalator Governor."

Similar presentations


Ads by Google