Download presentation
1
CENTRIFUGAL PUMP Module 3.2 MCP Construction
2
The same model can be fitted horizontally or vertically
MCP Horizontally fitted MCP Vertically fitted
3
Type symbol and meaning
MCP 155/4,5-L-3,5-WB-CB C/O Labyrinth Warm box Cold Box Speed x1000 Gear Box type Type Impeller diameter Impeller tipwidth Material A:Aluminium B: Mix aluminium /Bronze C: Bronze
4
New concept Modular in size : more than 10 sizes based on the same concept Unlimited flow range for low and medium pressure applications Modular in its composition Easy and low cost maintenance Plug-in cartridge concept Interchangeability / Minimum downtime for maintenance Modular in its options, all applications types All process or transfer applications Designed for optimal security
5
Vertical and horizontal pumps
Single stage Synchronous speed (50 or 60Hz) or variable speed Cold box installation. Warm box installation Valve chest (horizontal Position only) or insulated installation. All seal types available Slow-roll or cold standby Continuous or intermittent duty
6
A maximum of performances is covered by a minimum range of pumps.
F1, F2, F3, F4 correspondent à la standardisation des pièces pour les MCP et donc répondent à des groupes de pièces types brides, cold box, …
7
Intermediate piece on MCP
Outlet of the labyrinth heating coil grease retainer chamber coupling leak detector
8
Easy dismantling : simplified access and maintenance
9
Easy dismantling : simplified access and maintenance
10
MCP with Mechanical seal
11
MCP with Labyrinth seal
12
Valve Chest Design (ground mounted)
13
Cold Box Design
14
Typical MCP configurations
Horizontal Transfer Pump Open intermediate piece Sealing Mechanical or gas seal Ground Mounted Horizontal/vertical CB Transfer Pump Open intermediate piece Sealing Mechanical or gas seal Cold box installation flange
15
Typical MCP configurations (cont’d)
Horizontal WB Process Pump Purge warm box Purge grease retaining chamber Bearing heater Leak detection Sealing: Labyrinth or gas seal Ground mounted Horizontal WB CB Process Pump Purge warm box Purge grease retaining chamber Bearing heater Leak detection Sealing: Labyrinth or gas seal Cold Box installation flange
16
Typical MCP configurations (cont’d)
Horizontal WB VC Process Pump Purge warm box Purge grease retaining chamber Bearing heater Leak detection Sealing: Labyrinth or gas seal Ground mounted with valve chest Vertical CB WB Process Pump Purge warm box Purge grease retaining chamber Bearing heater Leak detection Sealing: Labyrinth or gas seal Cold Box installation flange
Similar presentations
© 2024 SlidePlayer.com. Inc.