What is the Problem? Sewer Line Inspection Methods Acoustic Inspection Technology Case Study Summary WWETT 2015 2
3
Overflows are a Symptom – Not the Problem 3 WWETT 2015
4
Example Charlotte, North Carolina ~4 miles Five Year Overflow Record – Different Color / Year 4 WWETT 2015 Overflow locations – “Random” >90% in pipes less than 12” Historical GIS – Helpful – But Insufficient Where & When to Deploy Cleaning Resources Cost Effective & Timely Condition Information
5
1020304050607080 0 5 10 15 20 25 % System Cleaned Annually Overflows / 100mi Charlotte 2 5 WWETT 2015 16 Municipalities Cleaning vs. SSO Occurrence Getting to 2 SSO’s/100 miles requires 76% cleaning on average
6
Target Historical Problematic Areas ◦ >70% Pipes Essentially Clean ◦ <10% Need Immediate Action Cleaning a Clean Pipe ⇒ Wastes Resources Not Cleaning a Dirty Pipe ⇒ SSO Acoustic Inspection Results ~6 Million Feet of Pipe WWETT 2015 6
7
What is the Problem? Sewer Line Inspection Methods Acoustic Inspection Technology Case Study Summary WWETT 2015 7
8
8 CCTV/Robotic Camera Pipe Profiling / Robotic Multi-Sensor Push Camera Zoom Camera Acoustic Manhole Inspection
9
What is the Problem? Sewer Line Inspection Methods Acoustic Inspection Technology Case Study Summary WWETT 2015 9
10
Patented technology Gravity-fed sewer focus Developed in Charlotte with CMUD as key partner 10 Over 12M feet inspected Rapid assessment helps better focus cleaning and CCTV resources WWETT 2015
11
How Does it Work? Transmitter “Yells” Receiver “Listens” 11 WWETT 2015
12
No Flow Contact / No Confined Space Entry Simple to use – train operators in minutes Low Cost–Pennies/foot Rapid Onsite Results – Under 3 min./segment Portable < 30 lbs GIS Integration – GPS Enabled Archive Pipe Segment Blockage Assessments 12 WWETT 2015
13
13 10 5 0 8 2 Obstructed No Obstructions Root Fibers Limited Growth Grease Limited Build Up Root Fibers and/or Grease Robot Can Pass Through Root Fibers and/or Grease Robot Cannot Pass Through Acoustic ScoreCCTV Comparison WWETT 2015
14
Blockage Assessment 10 Blockage Assessment 7 Blockage Assessment 5 CCTV Robot was Able to Pass Through Root Fibers Blockage Assessment 2 14
15
15 Sewer Line Data Organizer – SL-DOG Downloads SL-RAT data First step in enabling Condition Base Maintenance Productivity Management Measurement QA Visualize results in Google Earth or export to Excel Facilitates management of multiple devices WWETT 2015
16
16
17
WWETT 2015 17 Legend: SL-RAT In Field Pipe Assessment 0: 1-3: 4-6: 7-10:
18
What is the Problem? Sewer Line Inspection Methods Acoustic Inspection Technology Case Study Summary WWETT 2015 18
19
Founded 1822 Combined operations with Richmond County in 1996 Population Served 190,000 19 1,040 miles of sewer Covers 280 square miles Under GA EPD Consent Order WWETT 2015
20
Needed to get “outside the box” to meet the requirements of the Consent Order Needed to get a handle on SSO performance Hence, needed to get an overall snapshot of their system SL-RAT provided a simple low-cost solution with CBM capability 20 Augusta-Richmond County Service Area WWETT 2015
21
3 SL-RAT’s – purchased between 2/13 and 2/14 Run with 2 person crews per SL-RAT Averaging ~7500 feet PER 8 hour crew day Plan out inspection areas based on tax-maps Combined with manhole inspection program Acoustically screening entire system ~ 1x per year 21 WWETT 2015
22
QA Cleaning Fix GIS Issues Update Records Schedule Next Inspection 22 Street Name Parcel Address Line Sizes 1 Print Maps & Give to Crew 2 Conduct Inspections 4 Create Base Report 3 Download SL-RAT 5 Map Out in GIS 6 Generate Cleaning Crew Work Orders 7 Close Out Re-Charge SL-RAT WWETT 2015
23
>17,000 segments inspected in ~15 months of work >20,000 manholes located and inspected >3.6 MILLION Feet (682 miles) 23 17.3% Poor20.4% Fair 62.3% Good WWETT 2015
24
Trailing 12 Month SSO’s/Month SSO TREND WWETT 2015 24
25
WWETT 2015 25
26
What is the Problem? Sewer Line Inspection Methods Acoustic Inspection Technology Case Study Summary 26 WWETT 2015
27
1. The SL-RAT is simple, reliable, and easy to use 2. Keep up with the data - DAILY! Backlogs can get overwhelming 3. Forces discipline in visiting every manhole – identify issues, update GIS records, etc 4. Has focused efforts on the 38% of segments that are Poor or Fair 5. Requires teamwork to achieve full potential – cleaning crews, GIS, inspection crews – must all work together 6. Effective in economically reducing SSO rates 7. Future plans include historical trending with CityWorks 27 WWETT 2015
28
28 Phone:877-PIPECHK (877-747-3245) Email: achurchill@infosenseinc.com Website: www.infosenseinc.com WWETT 2015
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.