Download presentation
Presentation is loading. Please wait.
Published byShawna Cotton Modified over 9 years ago
1
Comparison of Damage Risk Criteria Using the Albuquerque Blast Overpressure Walkup Study Data William J. Murphy Amir Khan Peter B. Shaw Hearing Loss Prevention Section Division of Applied Research and Technology National Institute for Occupational Safety and Health William J. Murphy Amir Khan Peter B. Shaw Hearing Loss Prevention Section Division of Applied Research and Technology National Institute for Occupational Safety and Health The results reported in this paper represent the opinions of the authors and are not representative of the policies of the National Institute for Occupational Safety and Health. The results reported in this paper represent the opinions of the authors and are not representative of the policies of the National Institute for Occupational Safety and Health.
2
Blast Overpressure Studies
3
Outline Blast Overpressure Exposure Evaluations MilStd 1474D LAeq8hr Protected & Unprotected AHAAH Warned & Unwarned Statistical model for effects threshold Population Averaged Model Audiometric Failures Audiometric and Conditional Failures Dose Response Curves Blast Overpressure Exposure Evaluations MilStd 1474D LAeq8hr Protected & Unprotected AHAAH Warned & Unwarned Statistical model for effects threshold Population Averaged Model Audiometric Failures Audiometric and Conditional Failures Dose Response Curves
4
Outline continued Exposure Assessment Comparisons Threshold Estimates from BOP Study Fitting Performance Damage Risk Criteria Implications MilStd 1474D: 177 dB Limit LAeq8hr: 85 dBA Limit AHAAH: 500 Auditory Hazard Unit (AHU) limit Exposure Assessment Comparisons Threshold Estimates from BOP Study Fitting Performance Damage Risk Criteria Implications MilStd 1474D: 177 dB Limit LAeq8hr: 85 dBA Limit AHAAH: 500 Auditory Hazard Unit (AHU) limit
5
MilStd 1474D Free-Field Exposure
9
Statistical Analysis of BOP Data Obtained the waveforms from Data Archive from USAARL- MRMC and USARL – HRED MILSTD 1474D – B duration (also computed A & C durations) LAeq8hr – Protected and Unprotected AHAAH model – Protected Warned and Unwarned Checked against Chan et al. 2001, Ahroon & Patterson 2005, Price (2005), Jokel (2007) Obtained the injury data from USAARL-MRMC Checked the injury data against 1999 Contractor report DAMD17-96-6007 Obtained the waveforms from Data Archive from USAARL- MRMC and USARL – HRED MILSTD 1474D – B duration (also computed A & C durations) LAeq8hr – Protected and Unprotected AHAAH model – Protected Warned and Unwarned Checked against Chan et al. 2001, Ahroon & Patterson 2005, Price (2005), Jokel (2007) Obtained the injury data from USAARL-MRMC Checked the injury data against 1999 Contractor report DAMD17-96-6007
10
Applied a General Estimating Equations to evaluate the Population Averaged effects using xtgee in Stata. Represents the response pattern of the population as a whole Makes no assumptions regarding propagation of failure through to other exposure levels Tells us nothing about the chances of an individual subject failing within the exposure. Tells us about the chance of having a failure in the population. Applied a General Estimating Equations to evaluate the Population Averaged effects using xtgee in Stata. Represents the response pattern of the population as a whole Makes no assumptions regarding propagation of failure through to other exposure levels Tells us nothing about the chances of an individual subject failing within the exposure. Tells us about the chance of having a failure in the population. Statistical Analysis of BOP Data
11
Mil STD 1474 D 185 dB 193 dB
12
L Aeq8hr Unprotected Levels 115 dB 124 dB
13
L Aeq8hr Protected Levels 101 dB 109 dB
14
AHAAH Unwarned Model 3053 AHU 10109 AHU
15
AHAAH Warned Model 718 AHU 2480 AHU
16
5% Failure Thresholds L(95,95) Damage Risk Criterion Audiometric Failures Audiometric & Conditional Failures AHAAH Warned2480 AHU718 AHU AHAAH Unwarned10109 AHU3053 AHU L Aeq8hr Unprotected124 dB115 dB L Aeq8hr Protected109 dB101 dB MilStd 1474D193 dB185 dB
17
Five Exposure Assessments Compared Damage Risk Criterion Audiometric Failures Audiometric & Conditional Failures L Aeq8hr Unprotected273.73630.26 MilStd 1474 D282.01636.25 AHAAH Unwarned304.51650.85 L Aeq8hr Protected305.80650.05 AHAAH Warned307.13653.99 QIC: Lower value indicates a better fit QIC = Quasi Likelihood under the independence model Information Criterion
18
Mil-Std Observations Mil-Std 1474D L(95,95) with No Presumed Auditory Failures Chan : L(95,95) = 193 dB NIOSH : L(95,95) = 193 dB Chan’s analysis: Presumed Auditory Failures Add 9 dB for threshold of L(95,95) = 186 dB NIOSH analysis (Auditory & Conditional Failures) L(95,95) = 185 dB. Add 8 dB for Population Average threshold for the L(95,95) lower confidence bound. Mil-Std 1474D L(95,95) with No Presumed Auditory Failures Chan : L(95,95) = 193 dB NIOSH : L(95,95) = 193 dB Chan’s analysis: Presumed Auditory Failures Add 9 dB for threshold of L(95,95) = 186 dB NIOSH analysis (Auditory & Conditional Failures) L(95,95) = 185 dB. Add 8 dB for Population Average threshold for the L(95,95) lower confidence bound.
19
L Aeq8hr Observations L Aeq8hr Protected versus Unprotected French Weapon Noise Criteria: L Aeq8hr < 85 dB Unprotected Chan’s analysis without presumed failures L Aeq8hr < 100 dB Protected (assumed 15 dB for protectors) Unprotected limit 124 dB without presumed failures NIOSH analysis without presumed failures 14 dB HPD effect for Protection Unprotected limit: 124 dB Audiometric Failures Unprotected limit: 115 dB Aud. & Cond. Failures Protected limit: 101 dB Aud. & Cond. Failures L Aeq8hr Protected versus Unprotected French Weapon Noise Criteria: L Aeq8hr < 85 dB Unprotected Chan’s analysis without presumed failures L Aeq8hr < 100 dB Protected (assumed 15 dB for protectors) Unprotected limit 124 dB without presumed failures NIOSH analysis without presumed failures 14 dB HPD effect for Protection Unprotected limit: 124 dB Audiometric Failures Unprotected limit: 115 dB Aud. & Cond. Failures Protected limit: 101 dB Aud. & Cond. Failures
20
AHAAH Observations NIOSH Analysis L(95,95) Audiometric failures (no presumed failures) Unwarned Threshold = 10109 AHU Warned Threshold = 2480 AHU NIOSH Analysis L(95,95) Audiometric and Conditional Failures (no presumed failures) Unwarned Threshold = 3053 AHU Warned Threshold = 718 AHU AHAAH Model proposes a 500 AHU Limit which is more conservative than the data suggest NIOSH Analysis L(95,95) Audiometric failures (no presumed failures) Unwarned Threshold = 10109 AHU Warned Threshold = 2480 AHU NIOSH Analysis L(95,95) Audiometric and Conditional Failures (no presumed failures) Unwarned Threshold = 3053 AHU Warned Threshold = 718 AHU AHAAH Model proposes a 500 AHU Limit which is more conservative than the data suggest
21
Concerns for AHAAH Model Predictions of Hazard at Levels 3 & 4 not really tested in BOP study. Experiments can be designed to test this. Predictions of Hazard at Levels 3 & 4 not really tested in BOP study. Experiments can be designed to test this.
23
Concerns for AHAAH Model Justification for 500 AHU as a threshold limit Warned limit 718 or 2480 AHU – Population Average, L(95, 95) Unwarned Limit 3053 or 10109 AHU – Population Average, L(95, 95) Validation of the Warned/Unwarned middle ear No consideration given for adaptation/fatigue Model turns Warned condition ON but not OFF Justification for 500 AHU as a threshold limit Warned limit 718 or 2480 AHU – Population Average, L(95, 95) Unwarned Limit 3053 or 10109 AHU – Population Average, L(95, 95) Validation of the Warned/Unwarned middle ear No consideration given for adaptation/fatigue Model turns Warned condition ON but not OFF
24
Questions? William Murphy 4676 Columbia Parkway, MS C-27 Cincinnati, OH 45226-1998 wjm4@cdc.gov 513-533-8125 William Murphy 4676 Columbia Parkway, MS C-27 Cincinnati, OH 45226-1998 wjm4@cdc.gov 513-533-8125