1 LIBRARY INFRASTRUCTURE – A NEW PARADIGM

2 BUILDING PROGRAM: LIBRARY LOBBY LOBBY INFORMATION INFORMATION ISSUE AND RETURN ISSUE AND RETURN PROPERTY COUNTER PROPERTY COUNTER JOURNAL SECTION JOURNAL SECTION LENDING BOOKS AREA LENDING BOOKS AREA REFERENCE SECTION REFERENCE SECTION BOOK BANK BOOK BANK READING ROOM READING ROOM OFFICES SPACES FOR OFFICES SPACES FOR LIBRARIAN, DEPUTY LIBRARIAN LIBRARIAN, DEPUTY LIBRARIAN ACQUISITION AND TECHNICAL SECTION ACQUISITION AND TECHNICAL SECTION DOCUMENTATION CENTER DOCUMENTATION CENTER COMPUTER CENTER COMPUTER CENTER PARKING FOR 50 CARS AND 50 TWO WHEELERS PARKING FOR 50 CARS AND 50 TWO WHEELERS PROJECT: LIBRARY AND COMPUTER CENTRE LOCATION: Deen bandhu Chottu Ram University of Science and Technology, Murthal, Sonepat PLOT AREA: 17026 SQ.MT. Total Built up Area : 12,177 SQ.MT. PROJECT COST : Rs. 24.00 Crore

3 SITE PLAN GRASS PAVERS TO REDUCE HEAT ISLAND EFFECT TREES TO CREATE BUFFER FROM WEST SUN TREES TO CREATE BUFFER FROM WEST SUN TREES TO PROVIDE SHADE AND REDUCE HEAT ISLAND EFFECT EXISTING TREES CONSERVED EXISTING TREES CONSERVED EXISTING TREES CONSERVED CONVENTION CENTER LIBRARY / COMPUTER CENTER

4

5

6 EFFECTIVE DEPTH OF BUILDING FLOORS FOR OPTIMUM DAY LIGHT AND VIEWS N NATURALLY LIT FLOOR AREA : 80% EFFECTIVE DEPTH OF OPTIMUM DAY LIGHT AND VIEWS EFFECTIVE DEPTH OF OPTIMUM DAY LIGHT AND VIEWS GROUND FLOOR PLANFIRST FLOOR PLAN THIRD FLOOR PLAN SECOND FLOOR PLAN N N N NATURALLY LIT FLOOR AREA : 85% NATURALLY LIT FLOOR AREA : 80% NATURALLY LIT FLOOR AREA : 85%

7 High Efficiency Pumps High Efficiency AHUs, FCUs Heat Exchanger High Efficiency Chillers Reduced HVAC requirements Water Recycling & Conservation Reduced Lighting requirements Building Envelope design Sensors, Controls Daylighting High Performance Glazing Insulation Passive Systems High Efficiency Lamps, Ballasts, Luminaires Earth Air Tunnel Occupancy Load, Equipment Schedule Whole building energy optimization Reduced Energy requirements

8 EARTH AIR TUNNEL Earth air tunnel is a tunnel for the passage of calculated amount of air for the purpose of heating, ventilation and air conditioning of a space using natural heat of the earth four meter below earth surface. WHAT IS EARTH AIR TUNNEL :

9

10

11

12

13 FRONT VIEW

14 ATRIUM

15

16