28 Residential Electrical Chapter
3
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Objectives Explain the characteristics of electricity in terms of amperes, volts, resistance, and watts. Describe how electricity is delivered to and distributed through residential structures. Identify the three types of branch circuits used in a residential structure. Calculate circuit requirements for a residence.
4
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Objectives Describe the types of outlets and switches. used in a residence and their typical locations. Explain the advantages of low-voltage exterior lighting.
5
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Introduction Planning for electrical needs of home requires basic understanding of: –Related terms –Electrical requirements –Code restrictions –Safety considerations
6
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Electrical Terms Ampere (amp) Ohms Voltage Volt Watts –Amp Volts = Watts
7
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Service Entrance and Distribution Panel Service entrance –Fittings and conductors that bring electricity into building Distribution panel –Receives electricity and distributes it to various points in house through individual circuits
8
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Service Entrance and Distribution Panel Circuits consist of conductors that permit flow of electricity Distribution panel also contains main disconnect switch fuse or breaker
9
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Service Entrance Equipment Residence may have 120- or 240-volt service –Two conductors required for 120-volt service –Three conductors required for 240-volt service 240-volt service is recommended
10
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Service Entrance Equipment Incoming electrical service usually enters house through meter Service may be overhead or underground Conductors are generally run from service drop or from underground cable through run of heavy conduit
11
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Underground Service Layout
12
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Overhead Service Layout
13
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Service Entrance Designs Service head is used if service entrance is located along eaves line of single-story home Service drop must be: –At least 10 above grade at service entrance –12 above residential property and driveways Conductors must be at least 3 away from structures where they may be touched
14
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Conductor Sizing Conductors bring current from service head or underground cable to meter and then to distribution panel Conductor diameter increases as designation number decreases
15
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Conductor Sizing Smallest circuit conductor permitted by NEC is 14 AWG 12 AWG is recommended for branch lighting circuits If wire is too small for current, fire may result
16
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Distribution Panel Conductors from meter run to distribution panel Electricity is distributed to various points in house through branch circuits Distribution conductors are color-coded NEC recommends minimum of 100-amp service
17
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Typical Distribution Panel
18
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Overcurrent Protection Fuse –Fusible link –Cannot be reused Circuit breaker –Found in most new homes –Can be reset
19
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Branch Circuits Branch circuits –Lighting circuit –Small-appliance circuit –Individual circuit
20
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Lighting Circuits Serve permanently installed lighting fixtures and outlets for amps, radios, TVs, etc. Frequently 12 AWG copper wire conductor with 20-amp overcurrent protection Three watts of lighting power per sq. ft. of floor space is required One lighting circuit for each 400 sq. ft. is good rule of thumb
21
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Small-Appliance Circuits Located in the kitchen, garage, or shop Usually above a countertop or workbench Designed for tools and appliances that require large amounts of current –Electric fry pans, blenders, electric drills, power hand saws
22
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Small-Appliance Circuits 12 AWG copper wire with 20-amp overcurrent protection Lighting outlets should not be operated from these circuits NEC requires at least two small-appliance circuits in kitchen
23
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Individual Circuits Serve single, permanently installed appliances or equipment Each appliance has its own circuit Examples: –Air conditioner –Clothes washer –Dishwasher –Furnace –Range –Table saw –Water heater
24
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Individual Circuits Any 120-volt, permanently connected appliance that is rated over 1400 watts or starts automatically must also have its own circuit Individual circuits may be 120 or 240 volts
25
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Circuit Requirement Calculations Several factors affect size of service entrance and number of branch circuits –Size of house –Size and number of appliances –Lighting to be installed –Planned future expansions
26
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Circuit Requirement Calculations Example Size of residence = 1500 square feet Lighting circuits: (3 × 1500 = 4500 watts) Small-appliance circuits: 2 for kitchen (120 volts x 20 amp × 2 = 4800 watts) Individual circuits: 7 circuits (totaling 22,000 watts) Total = 31,300 watts/240 volts = 130.4 amps House will require 150 amp service
27
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Employability Professional language –No slang or profanity –Workplace communications should be polite, grammatically correct, and respectful –Professional language is essential to employability and workplace success
28
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Outlets and Switches Outlets, switches, and joints where conductors are spliced must be housed in electrical box Lighting fixtures must be mounted on box
29
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Outlets Lighting outlet Receptacle outlet –Also called receptacle or convenience outlet –General-purpose Special-purpose outlet –Examples: Telephone jacks, TV outlets, burglar alarm systems
30
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. GFCI Ground-fault circuit interrupter (GFCI) –Safety device that continually monitors flow of current in circuit GFCI responds in 1/30th of a second GFCIs can be placed as any receptacle NEC defines when and where GFCIs are used
31
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. GFCI Locations Kitchen –All receptacles serving countertop surfaces Bathroom –All receptacles Garage –All receptacles Outdoors –All receptacles that are readily accessible Unfinished basements and crawl spaces –All receptacles except for receptacle supplying permanently installed alarm system
32
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Switches Single-pole switch Three-way switch –Allows fixture to be switched from two locations Dimmer switch
33
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Locating Outlets and Switches Placement is affected by codes, furniture arrangements, and personal preference NEC requires that no point along a wall should be more than 6′ away from a receptacle outlet –8′ is recommended
34
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Locating Outlets and Switches Receptacle outlets: –12" or 18" above floor, except for kitchen Switches –48" above floor, in a logical place –30" to 40" is preferred for wheelchair users –Do not mount in inaccessible locations –Do not locate bathroom switches within reach of bathtub or shower
35
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Low-Voltage Exterior Lighting Good outdoor lighting is both functional and aesthetic Low voltage lighting system consists of lights, wire, one or more controllers, and transformers More expensive than 120-volt lighting, but safer and easier to install
36
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Planning Low-Voltage Exterior Lighting Decide where light is needed for safety, security, and activities Then plan for decorative lighting Try to avoid glare Outdoor light fixtures are either decorative or hidden
37
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Planning Low-Voltage Exterior Lighting Use shielded fixtures to hide light source Hide fixtures where they cannot be seen Use more, smaller lights Remember safety when planning lighting Use light to shape an outdoor space
38
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Low-Voltage Wiring Considerations Lights farther away from transformer produce less light due to voltage drop Put no more than 100 watts of lighting on one leg of tee
39
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Low-Voltage Wiring Considerations Choose proper size transformer Use GFCI receptacle as power source Consider indoor switch and timer combination Try to prevent corrosion before it starts Call utility company before digging
40
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Low-Voltage Wiring Considerations Leave a little extra wire in layout After checking entire setup, bury wires at least 6" deep
41
Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Architecture Passive energy sources –Solar, wind, or geothermal –Research what systems are available –Check code restrictions –May cost more but can be much more sustainable Green