2
2 Quality Construction Features Standard Operating Parameters Maximum Boiler Design Pressure All Models – 160 Psig Maximum Boiler Design Temperature All Models – 210° F. Gas pressure All Models - 14”w.c.min / 2# max
3
3 Quality Construction Features Standard Operating Parameters Power Requirements TF150 & TF200 - 208-240/1/60vac TF250 & TF300 - 208-240/3/60vac DC Motor Horsepower TF150 & TF200 - 1.4 H.P - 6 FLA TF250 & TF300 - 4.0 H.P - 16 FLA
4
4 Quality Construction Features Standard Operating Parameters Minimum Entering Water Temperature 50 ° F. Standard Relief Valve Settings 30#, 45#, 60# or 125# Stack Type Category IV AL29-4C Material High Altitude Firing 4% De-rate per 1,000ft above 2,000ft 5,000ft De-rate Example: 5,000ft-2,000ft=3,000ft 3,000ft/1,000ft=3 3x4%=12% de-rate
5
5 Triple-Flex Water & Combustion Air Flow
6
6 Quality Construction Features Tubes Size - 1½“ Nominal O.D. Reduced to 1”O.D. The reduction allows setting the tubes side by side rather than staggering them as done in our current manufacturing process. Flexible 8 Pass Design - Furnace Section 10 Pass Design - Convection Section Incorporated the traditional BRYAN standard two flex tube design concept
7
7 Quality Construction Features Tubes Material #316L Stainless Steel End-Formed Single Side Tube Access BRYAN has incorporated single-sided boiler access as standard on most of it’s boilers and this feature is maintained on the Triple-Flex.
8
8 Triple-Flex Tubes Furnace Convection End-Formed
9
9 Quality Construction Features Exterior Boiler Features Suspended Jacket Frame Reducing Jacket Losses Standard 16 Gauge Durable Powder Coated Finish Hammer Tone Grey Color Access Panels - Removable on Sides & Back Hinged Front Access Control Panel Door Replaceable Standard Sized Intake Air Filter 20”x25” Fiberglass Media
10
10 Triple-Flex Access Panels
11
11 Quality Construction Features Interior Boiler Features Three Combustion Gas Pass Sections One Furnace Section Two Convection Sections Flue Collector Material #304L Stainless Steel – Top & Sides Special Floor / Drain Pan Material AL6-XN Stainless Steel Highly Resistant to Corrosion
12
12 Boiler Construction View (Access Side)
13
13 Boiler Construction View (Opposite Side)
14
14 Boiler Cut-Away View
15
15 Quality Construction Features Efficiency Enhancement Features Fireside Heating Surface Minimum Nine (9) Sq. Ft. per BHP Air Cooled Outer Jacket Pre-heats Combustion Air High Efficiency Air-to-Air Exchanger Material - #3003 Aluminum
16
16 Air-to-Air Heat Exchanger
17
17 Air-to-Air Heat Exchanger
18
18 Quality Construction Features Gas Burner Manufactured by BRYAN Forced Draft Hybrid Metal Fiber Type Turndown Ratio TF150 & TF250 - 4:1 Turndown TF200 & TF300 - 5:1 Turndown Sub 30 PPM Low NOx Sub 9 PPM with 10% De-rate Gas Valves Dual Motorized - Standard Vent-less
19
19 BRYAN Hybrid Metal Fiber Burner
20
20 Quality Construction Features Pressure Switches High Gas Pressure Switch – Vent-less Low Gas Pressure Switch – Vent-less Pilot Low Gas Pressure Switch – Vent-less Burner High Air Pressure Switch Exchanger High Air Pressure Switch Flow Switches Combustion Air Flow Switch Water Flow Switch
21
21 Quality Construction Features Standard Operating Controls Indicator Lights Power On – White Enabled – Green Fuel On – Amber Alarm – Red Probe Type Low Water Cutoff with M/R 24 Hour Repeat Cycle Timer – via Sola Control
22
22 Quality Construction Features Standard Operating Controls Standard Tie-In Points Boiler Status – Fuel On - 120vac 75va General Alarm - 120vac 75va Standard Terminals Enable / Disable Aux. Recycle Interlock
23
23 Quality Construction Features Standard Operating Controls Boiler Pressure Gauge Boiler Temperature Gauge On/Off Switch Operator & Limit Controls via Sola Control Boiler Lock-out Reset Switch Fused Single Point Power Connection Control Circuit Transformer – 208-240vac to 120vac
24
24 Boiler Control Center
25
25 Quality Construction Features Boiler Control Center Honeywell “ SOLA” Commercial Hydronic Safety Control & Interface System LCD Touch Screen Display Boiler Control Point Monitoring Supply Water Temperature Stack Flue Gas Temperature Power Burner Operations
26
26 Quality Construction Features Boiler Control Center Honeywell “ SOLA” Commercial Hydronic Safety Control & Interface System Operating Status of: Firing Rate Combustion Blower Speed Boiler Set Point Flue Outlet Temperature Alarms Displayed via Sola Display Flame Fail, Low Water, High Limit Low Gas Pressure, High Gas Pressure Air Flow, Pilot Fail and More
27
27 Quality Construction Features Boiler Control Center Honeywell “ SOLA” Commercial Hydronic Safety Control & Interface System Modify Operating Temperature Settings Accepts 4-20mA Signal From EMS / BMS Standard Enable / Disable Terminals Lead / Lag Control for Up to 8 Boilers ModBus Communications Protocol Temperature Input for either Outdoor Reset or Header Temperature ( Sensor Optional) Input for Return Water Temperature (Sensor Optional)
28
28 Honeywell “SOLA” Control
29
29 Honeywell “SOLA” Control Examples of Low and High Firing Rates Notice the Stack and Outlet Temperature
30
30 Quality Construction Features Optional Features Available Reverse Construction Auxiliary LWCO Probe Type – Mounted in Rear of Boiler Float Type – Mounted in Field in System Piping Combustion Air Filter Housing with Flange Ducted Air Connection 20” x 25” Neutralizer Kit
31
31 PH Neutralizer Kit
32
32 Triple-Flex Thermal Shock Warranty Lifetime Non-Pro-Rated: To Original Owner & Installation Covers Failure of Pressure Vessel Upper and Lower Headers Tubes When Due to Unequal Expansion, Often Described as “Thermal Shock”
33
33 Triple-Flex Corrosion Warranty Covers Failure Due to Corrosion from Flue Gas Condensation: 10 Years Upper and Lower Headers 5 Years Flexible Water Tubes Flue Collector
34
34 Triple-Flex Limited Parts Warranty Metal Fiber Burner Head: 24 Months From Date of Shipment Boiler, Burner & Controls: 12 Months From Date of Start-up or 18 Months From Date of Shipment, Whichever Occurs First
35
35
36
36 Key Features Quality Construction Special New Tubes Flexible Stainless Steel End-Formed Boiler Efficiency Enhancement Minimum 9 sq. ft. of Heating Surface per BHP Air Cooled Jacket Pre-heated by Combustion Air Air-to-Air Exchanger Flue Collector – 100% Stainless Steel
37
37 Key Features Quality Construction Gas Burner By Bryan Hybrid metal fiber High Turndown Low NOx Honeywell “ SOLA” Boiler Control Center Touch screen Burner / Boiler Operations Lead / Lag Outdoor Reset Communications
38
38 Key Features Guaranteed Efficiency 90 % Utilizing Standard Operating Water Temperatures: 160°F. Return & 180°F. Supply Greater Efficiency Efficiencies up to 98% by Utilizing Cooler Operating Water Temperatures Example: 80°F. Return & 100°F. Supply
39
39 Guaranteed Efficiency
40
40 Bryan Steam, LLC 783 North Chili Avenue Peru, Indiana 46970 Phone: 765-473-6651 www.bryanboilers.com