Download presentation
Presentation is loading. Please wait.
Published byLondon Spensley Modified over 9 years ago
1
CIM Test Development Process John Simmins Weekly Status and Planning Meeting 5/3/2011
2
2 © 2011 Electric Power Research Institute, Inc. All rights reserved. Agenda 1.Progress since last meeting 2.Issues, opportunities and risks arising during the previous week 3.Verify progress against stakeholder expectations 4.General issues discussion 5.Action items for individuals 6.Expected work output during next week
3
3 © 2011 Electric Power Research Institute, Inc. All rights reserved. Progress Since Last Call Sample messages created for all test procedures –Scheduled Meter Reading –On Demand Meter Reading –Tampering Detection –Disconnect/Reconnect
4
4 © 2011 Electric Power Research Institute, Inc. All rights reserved. Issues, opportunities and risks arising during the previous week Figure 45 – Example message exchange for meter connect/disconnect Necessary? Reference: 61968 Part 9 April 12 Version
5
5 © 2011 Electric Power Research Institute, Inc. All rights reserved. Nouns 61968 Part 9 Correct?
6
6 © 2011 Electric Power Research Institute, Inc. All rights reserved. Message XSD Allowable Verbs This enumerated list of verbs that can be used to form message types in compliance with the IEC 61968 standard. Deprecated?
7
7 © 2011 Electric Power Research Institute, Inc. All rights reserved. Sample CreateMeterReadSchedule Message <CreateMeterReadSchedule xmlns=" http://www.iec.ch/TC57/2011/MeterReadScheduleMessage" xmlns:obj="http://iec.ch/TC57/2011/MeterReadSchedule#" xmlns:msg="http://www.iec.ch/TC57/2010/schema/message" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.iec.ch/TC57/2011/MeterReadScheduleMessage MeterReadScheduleMessage.xsd"> create MeterReadSchedule TESTING 2001-12-17T09:30:47.0Z CIS-001 true CIS-001 true CIS-12345 This is test 2.01 - Scheduled Meter Reading 3dc53ee5-777e-50b4-8699-a1c224f45f3d Meter 12345
8
8 © 2011 Electric Power Research Institute, Inc. All rights reserved. CreatedMeterReadings Message, 1 of 3 <CreatedMeterReadings xmlns="http://www.iec.ch/TC57/2011/MeterReadingsMessage" xmlns:obj="http://iec.ch/TC57/2011/MeterReadings#" xmlns:msg="http://www.iec.ch/TC57/2010/schema/message" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.iec.ch/TC57/2011/MeterReadingsMessage F:\Z_NewFiles\SampleFiles\MeterReadingsMessage.xsd"> created MeterReadings String TESTING 2001-12-17T09:30:47.0Z HE-001 false MSG-001 CIS-12345 Scheduled meter read
9
9 © 2011 Electric Power Research Institute, Inc. All rights reserved. CreatedMeterReadings Message (2 of 3) true 3dc53ee5-777e-50b4-8699-a1c224f45f3d billing 2001-12-17T09:30:47.0Z 3.14159E0 2001-12-17T09:30:47.0Z
10
10 © 2011 Electric Power Research Institute, Inc. All rights reserved. CreatedMeterReadings Message (3 of 3) true 3dc53ee5-777e-50b4-8699-a1c224f45f3d billing 2001-12-17T09:30:47.0Z 3.14159E0 2001-12-17T09:30:47.0Z
11
11 © 2011 Electric Power Research Institute, Inc. All rights reserved. Sample Tamper Detection Message (1 of 2) <CreatedEndDeviceEvents xsi:schemaLocation="http://www.iec.ch/TC57/2011/EndDeviceEventsMessage EndDeviceEventsMessage.xsd" xmlns="http://www.iec.ch/TC57/2011/EndDeviceEventsMessage" xmlns:obj="http://iec.ch/TC57/2011/EndDeviceEvents#" xmlns:msg="http://www.iec.ch/TC57/2010/schema/message" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"> created EndDeviceEvents TESTING 2011-04-12T10:00:00Z HE-001 false true ABC-123 Pre-configured_Request created end device events for testing tamper
12
12 © 2011 Electric Power Research Institute, Inc. All rights reserved. Get Meter Readings-On Demand Sample Msg <GetMeterReadings xmlns="http://www.iec.ch/TC57/2011/GetMeterReadingsMessage" xmlns:obj2="http://iec.ch/TC57/2011/GetMeterReadings#" xmlns:obj1="http://iec.ch/TC57/2011/MeterReadings#" xmlns:msg="http://www.iec.ch/TC57/2010/schema/message" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.iec.ch/TC57/2011/GetMeterReadingsMessage GetMeterReadingsMessage.xsd"> get MeterReadings TESTING 2001-12-17T09:30:47.0Z CIS-001 false ABC-123 On-Demand read request String 3dc53ee5-777e-50b4-8699-a1c224f45f3d Meter23253
13
13 © 2011 Electric Power Research Institute, Inc. All rights reserved. Response Meter Readings-On Demand Sample Msg (1 of 2) <MeterReadingsResponseMessage xmlns="http://www.iec.ch/TC57/2011/GetMeterReadingsMessage" xmlns:obj2="http://iec.ch/TC57/2011/GetMeterReadings#" xmlns:obj1="http://iec.ch/TC57/2011/MeterReadings#" xmlns:msg="http://www.iec.ch/TC57/2010/schema/message" xmlns:xsi="http://www.w3.org/2001/XMLSchema- instance" xsi:schemaLocation="http://www.iec.ch/TC57/2011/GetMeterReadingsMessage GetMeterReadingsMessage.xsd"> reply MeterReadings TESTING 2001-12-17T09:30:47.0Z HE-001 false HE-12345 ABC-123 On-Demand meter read reasponse
14
14 © 2011 Electric Power Research Institute, Inc. All rights reserved. Response Meter Readings-On Demand Sample Msg (2 of 2) OK false 3dc53ee5-777e-50b4-8699-a1c224f45f3d Meter23253 inquiry 2001-12-17T09:30:47.0Z HE-001 2001-12-17T09:30:47.0Z 314159
15
15 © 2011 Electric Power Research Institute, Inc. All rights reserved. Sample Tamper Detection Message (2 of 2) 2011-04-12T09:30:30Z Electric Meter Alarm Tamper (General Tamper) 3dc53ee5-777e-50b4-8699- a1c224f45f3d Meter23253
16
16 © 2011 Electric Power Research Institute, Inc. All rights reserved. Sample Remote Disconnect Message (header) create EndDeviceControls TESTING 2001-12-17T09:30:47.0Z String false MDMS-12345 String Meter disconnect request
17
17 © 2011 Electric Power Research Institute, Inc. All rights reserved. Sample Remote Disconnect Message (payload) String 0 true String disconnect 3dc53ee5-777e-50b4-8699-a1c224f45f3d Meter23253
18
18 © 2011 Electric Power Research Institute, Inc. All rights reserved. Sample Remote Reconnect Response Message <EndDeviceControlsResponseMessage xmlns="http://www.iec.ch/TC57/2011/GetEndDeviceControlsMessage" xmlns:obj1="http://iec.ch/TC57/2011/EndDeviceControls#" xmlns:obj2="http://iec.ch/TC57/2011/GetEndDeviceControls#" xmlns:msg="http://www.iec.ch/TC57/2010/schema/message" xmlns:xsi="http://www.w3.org/2001/XMLSchema- instance" xsi:schemaLocation="http://www.iec.ch/TC57/2011/GetEndDeviceControlsMessage GetEndDeviceControlsMessage.xsd"> reply EndDeviceControls TESTING 2001-12-17T09:30:47.0Z HE-001 false HE-12345 MDMS-12345 Disconnect received OK
19
19 © 2011 Electric Power Research Institute, Inc. All rights reserved. ChangedMeterServiceRequests (1 of 2) <ChangedMeterServiceRequests xmlns="http://www.iec.ch/TC57/2011/MeterServiceRequestsMessage" xmlns:obj="http://iec.ch/TC57/2011/MeterServiceRequests#" xmlns:msg="http://www.iec.ch/TC57/2010/schema/message" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.iec.ch/TC57/2011/MeterServiceRequestsMessage MeterServiceRequestsMessage.xsd"> changed MeterServiceRequest TESTING 2001-12-17T09:30:47.0Z HE-001 false MDMS-12345 CIS-12345 disconnect completed
20
20 © 2011 Electric Power Research Institute, Inc. All rights reserved. ChangedMeterServiceRequests (2 of 2) construction 2001-12-17T09:30:47.0Z normal 2001-12-17T09:30:47.0Z String 3dc53ee5-777e-50b4-8699-a1c224f45f3d HE-001 2S 123-456-789 serviceDisconnect 2001-12-17T09:30:47.0Z HE-001 2001-12-17T09:30:47.0Z 3.14159E0 Meter23253
21
21 © 2011 Electric Power Research Institute, Inc. All rights reserved. Expected Work Output During the Next Week 3 Webinars with the Vendors –WednesdayMay 4 11:00 AM - 12:00 PM –FridayMay 6 9:00 AM - 10:00 AM –Monday May 9 12:00 PM - 1:00 PM.
22
22 © 2011 Electric Power Research Institute, Inc. All rights reserved. Together…Shaping the Future of Electricity