1
January 2005 An Introduction to Entro 5 The Access Security Group
2
Content Introduction System configuration System components
Specific functions Lift control Alarm control Reservation Bewator Entro January 2005
3
Secure your premises with Bewator Entro
Easy to plan Project Design Manual Flexible system architecture Easy to install Modern technology Distributed intelligence Easy to expand Easy to upgrade Easy to use Windows platform User friendly Bewator Entro January 2005
4
Secure your premises with Bewator Entro
More than 55,000 systems sold in 20 countries Nine language versions: (English, Swedish, Danish, Norwegian, Finnish, German, French Belgium-Dutch and Spanish) Has all the features that 95% of the market requires…! Unique Web-based Reservation feature BAPSI – Open TCP/IP software interface for 3rd party software applications Bewator Entro January 2005
5
Bewator Entro 5 - capacity
Software for 1,000 sites TCP/IP, Modem or Direct connect(RS232) 512 Doors 20,000 Cardholders 480 Access groups 240 Time schedules 240 Zones Intruder Alarm control Anti-pass back Roll call Entrance limitation Interlock (Airlock) 64 Reservation objects Lift control Bewator Entro January 2005
6
System overview Different levels
PC for Entro SW Segment Controllers SR34i Door environments, e.g. Door Controllers DC-12, DC-22 and Readers Communication - RS232 - RS485 - Modem - TCP/IP on LAN or WAN System - Mirrored database between PC <-> SR34i <-> SR34i - Event backup in SR34i (10,000 latest events) PC LAN SR34i SR34i SR34i Segment Controllers 1 2 16 DC-22 DC-12 DC-12 DC-12 Door environments 1 2 3 32 Bewator Entro January 2005
7
Door environments Distributed intelligence Reading technology
Proximity Cotag® Hands-Free 1m reading distance Loop Readers Glass Readers Magnetic Stripe Bank & credit cards… Reader interfaces - BC-link - Clock & Data - Wiegand Communication Local bus Bewator Entro January 2005
8
Security in the system System name Software login PC name
Unique to every system/database Software login Different levels PC name When using a Multiple user database Automatic logoff Protects from unauthorised use 128 bit encryption When TCP/IP is used Mirrored database Easy recovering (backup/upload) Event backup 10,000 events stored in SR34i Bewator Entro January 2005
9
System configurations
Different structure
10
Configuration example
Local bus Max 1200 m Start with a small system Local RS485 bus Reception Bewator Entro January 2005
11
Configuration example
Expand to a bigger system with several SR34i - still using RS485 Local RS485 bus Reception Global RS485 bus RS232 or TCP/IP Security Manager Bewator Entro January 2005
12
Configuration example
Change over to TCP/IP network Local RS485 bus Reception TCP/IP Local Area Network Security Manager Bewator Entro January 2005
13
The way many competitors use TCP/IP
Only the PC workstations use TCP/IP, not the security hardware! Must have a server! Network server Local Area Network Controller Controller Bewator Entro January 2005
14
The way many competitors use TCP/IP
January 2005 The way many competitors use TCP/IP Or like this: Need of a third party product! More complicated set-up! Ethernet Interface Ethernet Interface Local Area Network Controller Controller Bewator Entro January 2005
15
Bewator Entro solution
SR34i connects directly to LAN Integrated Ethernet interface SR34i communicate without PC Built in 2-port switch in SR34i Fixed or Dynamic IP addresses 10 or 100 Mbit Multiple user database (16 users) Easy installation and set-up Cost effective Flexible Reliable Local Area Network Bewator Entro January 2005
16
A true global system ! Internet Local network Global network
RS485 RS485 RS485 RS232 Local network SR32i SR32i SR32i Global network TCP/IP Local Area network Internet Reservation Web Reservation Web Reservation Reservation SR32i Local Area network TCP/IP TCP/IP Bewator Entro January 2005
17
System components SR34i Segment Controller DC-22 Door Controller
IOR6 Input/Output Unit DT-05 Compact Cardreader Readers for DC-22/DC-12 Different reading technology
18
SR34i Segment Controller
January 2005 SR34i Segment Controller The Master in the system contains the full database (same as in the PC). The Database is “mirrored” between all SR34i and the PC, this can up-load the database in the event of a crash Event backup (10,000 latest) Up to 16 Segment Controllers in one system, controlling different amounts of doors (4, 8, 16 or 32 doors) Standard interfaces: - RS232 for PC or Modem - RS485 for Global and Local bus - TCP/IP for PC and Global bus on LAN/WAN Integrated Web server Integrated keyboard and display for programming and system feedback Bewator Entro January 2005
19
SR34i Segment Controller (inside)
January 2005 SR34i Segment Controller (inside) Display for system info and status Removable terminal blocks for Global and Local RS485 communication Compact Flash memory socket Address selection 1-16 Tamper switch 9-pin D-type RS232 connector Battery for memory backup Built-in 2-port switch with 2xRJ45 Ethernet connectors for 10/100 Mbit TCP/IP communication All electronics in a easy replaceable module Key to lock the unit Keyboard for programming Bewator Entro January 2005
20
DC-22 Door Controller A new display for status and error codes
January 2005 DC-22 Door Controller A new display for status and error codes BC-link, Clock&Data or Wiegand Reader interface Up to 16 digits card numbers In&Out Readers using BC-link for live roll call and anti-pass back Six relay outputs, 2xLock, 2xWarning, Alert and Intruder Alarm Interface Used as a Master in an Intruder Alarm zone Input for alarm status feedback, informs the access system when the intruder system is set or un-set) Can store 100 priority Cards for emergency access Upgradeable flash memory LÅS LFK LYSDIOD DÖRRKONTAKT - LÅSKONTAKT TVÅ LÄSARE OLIKA TYPER AV LÄSARE Bewator Entro January 2005
21
DC-22 Door Controller (inside)
January 2005 DC-22 Door Controller (inside) Display for status and error codes Screw holes under the corner details Tamper switch for open lid Address selection (1-32) Cable entry with knockouts All terminal blocks are removable and in yellow for best visibility Cable tie to secure the cable Voltage select for the Reader +5V or +Vin Corner details can be lifted for nice and easy cable installations (Option) Tamper switch for unit removed from wall Most electronics protected on the back of the easy replaceable PCB Bewator Entro January 2005
22
DC-22 Door Controller Terminal blocks
January 2005 DC-22 Door Controller Terminal blocks Inputs for: - ASF (Alarm Status Feedback) - Red LED control (BC-Link Readers only) Relay outputs for: - Pre-warning Alarm - Door warning - Alert Alarm bypass relay output and alarm Button/Timer input Power supply (12-24V DC) and Local RS485 bus “to the next door” Relay output for Motor lock Power output for the Electric lock (12 or 24V DC, 1,4 A) and Opening relay Reader connection with BC-Link interface Reader connection with Clock&Data or Wiegand interface Inputs for: - Exit button - Door contact - Lock contact Bewator Entro January 2005
23
DC-12 Door Controller A new display for status and error codes
January 2005 DC-12 Door Controller A new display for status and error codes BC-link, Clock&Data or Wiegand Reader interface Up to 16 digits card numbers In&Out Readers using BC-link for live roll call and anti-pass back One relay output for Lock Can store 100 priority Cards for emergency access Upgradeable flash memory BB6 SKYDDAR 5 VOLT (20 METER) 12 VOLT (50 METER) TVÅ LÄSARE MED MULTIBOX Bewator Entro January 2005
24
DC-12 Door controller (inside)
January 2005 DC-12 Door controller (inside) Display for status and error codes Screw holes under the corner details Tamper switch for open lid Cable entry with knockouts Address selection (1-32) Cable tie to secure the cable Voltage select for the Reader +5V or +Vin All terminal blocks are removable and in yellow for best visibility Corner details can be lifted for nice and easy cable installations Most electronics protected on the back of the easy replaceable PCB Bewator Entro January 2005
25
DC-12 Door Controller Terminal blocks
January 2005 DC-12 Door Controller Terminal blocks Power supply (12-24V DC) and Local RS485 bus “to the next door” Inputs for: - Exit button - Door contact Power output for the Electric lock (12 or 24V DC, 1,4 A) and Opening relay Reader connection with BC-Link interface Reader connection with Clock&Data or Wiegand interface Bewator Entro January 2005
26
Readers for DC-12 and DC-22 Hands-Free Magnetic Stripe Proximity
HD500 (Heavy Duty) SP500 (Switch Plate) PM500 (Panel Mount) BC-43Prox (Card+PIN) Magnetic Stripe BC-43 BC-16 Proximity Keypad M-43 Hands-Free HF500-Entro (internal) BC-5511 (external) Custom Covers Glass Readers Bewator Entro January 2005
27
DT-05 with it’s dropbox Compact solution All connections in the Reader
January 2005 DT-05 with it’s dropbox Compact solution All connections in the Reader Two variants (reading technologies) DT-05 (Magnetic Stripe) DT-05Prox (Proximity) Mainly for indoor use, but can also be mounted outdoors Com. Local bus VISA JACKBAR PLINT KOMPAKT SABOTAGEKONTAKT Bewator Entro January 2005
28
IOR6 Input/Output Unit Features: Used for:
2 voltage free Switching relays 4 voltage free Closing relays 6 extra outputs, (switches simultaneously) 4 remote inputs Used for: Lift Control (Up to 192 floors. Controlled by any Reader in the system) Machine control (For controlling machines, lights etc when use of Reservation) Timer control (Activate each relay via an time schedule) Alarm outputs (Activate each relay via an alarm event, set by a filter) Power Fail input (From battery back-up, generates an event/alarm) Emergency opening input (From a Fire alarm, opens all door in the system) Bewator Entro January 2005
29
DC-01 Door controller No Reader connection
January 2005 DC-01 Door controller No Reader connection Output for Electric lock (timer operated) Input for Door contact Input for Exit request Com. Local bus An excellent controller for monitoring doors where no Readers are needed Bewator Entro January 2005
30
Lift control Alarm control Reservation
Specific functions Lift control Alarm control Reservation
31
Lift Control Any Reader (Master) controls one or several IOR6
Access rights to each floor (relay) is controlled by access groups Lift control SR34i DC-12 DC-12 DC-12 DC-12 Lift Bewator Entro January 2005
32
Alarm by-pass Monostable alarm bypass Bistable alarm control
January 2005 Alarm by-pass Monostable alarm bypass Bistable alarm control Pulse alarm control Alarm zones created in the software, no extra wiring ASF (Alarm Status Feedback), synchronises Entro and the Alarm system Red LED control Alarm activation via time schedule Pre-warning in Readers and relay in DC-22 4 different rights to control the Alarm: - Activate & Deactivate - Only Activate - Only Deactivate - No alarm control Bewator Entro January 2005
33
Alarm zones Alarm zone 1, Shop: Reader 1, 2 and 4 Alarm zone 2, Stock:
Alarm system DC-22 SR34i STOCK SHOP 4 3 DC-12 6 DC-22 DC-12 DC-12 5 2 Bewator Entro January 2005
34
Reservation system Integrated as a module in the access control system
For reserving access to premises Conference rooms, clubs Squash, tennis courts Solarium, laundry rooms Reservation terminal InfoPoint IP810 or IP811 Internet reservation Confirmation via Fixed or Free time reservation Machine control Random reservation Bewator Entro January 2005
35
InfoPoint IP810 and IP811 Reservation terminal with web functions
TFT Colour screen 400x200 Menu driven, easy-to-use Several languages TCP/IP connection 10 Mbit Integrated Proximity Reader for login IP810 IP811 Bewator Entro January 2005
36
Example - Solarium Bewator Entro TCP/IP
Web Reservation and/or Administration of Entro TCP/IP Solarium (Reservation node) TCP/IP DC-12 SR34i InfoPoint IP810 CF8 RS485 with CF8 Bewator Entro January 2005
37
with machine & door control
Example - Solarium with machine & door control Web Reservation and/or Administration of Entro TCP/IP Solarium (Reservation node) TCP/IP DC-12 SR34i InfoPoint IP810 CF8 RS485 with CF8 IOR6 Bewator Entro January 2005
38
Reservation in LAN/WAN with machine & door control
Example - Solarium Reservation in LAN/WAN with machine & door control Web Reservation and/or Administration of Entro Internet TCP/IP TCP/IP TCP/IP Network - LAN Solarium (Reservation node) TCP/IP DC-12 SR34i InfoPoint IP810 CF8 RS485 with CF8 IOR6 Bewator Entro January 2005
39
Login for Web reservation
Bewator Entro January 2005
40
Reservation page with fixed time intervals
Bewator Entro January 2005
41
Reservation page with free time intervals
Bewator Entro January 2005
42
E-mail confirmation of reservation
Bewator Entro January 2005
43
Bewator Entro www.bewator.co.uk
A cost effective high security solution! Contact Bewator on for more information or visit our website: Bewator Entro January 2005