1 Detention Cisterns for CSO Control Bob Spencer Seattle Public Utilities www.seattle.gov/util/greeninfrastructure www.seattle.gov/util/RainWise

2 SPU’s CSO System 87 outfalls 300 overflows per year on average for 2010-2011 134 million gallons into Seattle lakes, streams, and Puget Sound 2

3 Realtime CSO website Long Term Control Plan Site RainWise Home Page RainWise Tools Seattle Public Utilities3

4 What is RainWise? General technical information Rebates for property owners in target CSO basins

5 The Rain Wise Toolbox Rainfall: - slow it - spread it - filter it - soak it in.

6 6 RainWise Eligible Basins Til December 2016

7 Locating and Planning Cistern Installations for Stormwater Management Downspout Screened inlet Overflow Drain to garden hose For more information, see the Cistern factsheet and other resources at www.seattle.gov/util/rainwise

8 Seattle Public Utilities8 Is this a good site for a cistern? A cistern installation needs:  A level location near a downspout, outside (not inside building)  A solid base (6” of packed 3/8 crushed rock)  To allow ingress and egress for people  Don’t block doors, windows, vents, or utilities accesses  A safe place to discharge the overflow, a minimum of: –5 feet from your home (with no basement) –10 feet from your home, if you have a basement –5 feet from a property line, and 10 feet from neighboring buildings –or connect overflow to sewer (requires side sewer permit – call DPD at # on RainWise factsheet)

9 Constructing Cistern Installations for Stormwater Management www.seattle.gov/util/rainwise Downspout Screened inlet Overflow Lowflow orifice

10 Example Cistern Layout Follow manufacturer’s instructions! Gutter (ideally with leaf screens) Downspout Self-cleaning leaf filter Screened inlet Finer screens keep more dirt out. Overflow – 3-4 inch pipe, with ”P” trap Cistern – typically heavy plastic or fiberglass Disperse overflow into landscape A minimum of: - 5 ft. from house, or 10 ft. with basement - 5 ft. from property line, - 10 ft. from neighboring buildings Level foundation – 6 inches of packed 3/8” crushed rock, or concrete block, over packed subsoil Drain – 3/4 inch pipe with faucet Connect garden hose to drain to yard in winter. Close faucet in May to store water for summer. screen Cleanout plug (3 to 4 inch diameter) Clean tank annually by squirting hose into inlet and cleanout, and scrubbing with long- handled brush.

11 Seattle Public Utilities11 What makes a cistern work for storm water detention? The “low-flow orifice” In this case, a faucet that’s left open October-May, to allow tank to drain out between storm events, so there’s space to store and slowly release the next rainfall. Cisterns must have a ¼-inch orifice plumbed to the landscape or sewer. For non-rebate homeowner projects, a faucet & garden hose works fine. If the cistern is full when it rains hard, it provides no stormwater benefit – it must be able to drain between storms.

12 Low-flow orifice plumbing for Code-permitted cisterns (example from Lakewood project) Seattle Public Utilities12

13 Seattle Public Utilities13

14 Modeling % Reduction for Rebate Value Seattle Public Utilities14

15 15 Step 1: Build a level foundation to support a cistern full of water Excavate topsoil at least 3 inches: create hard a level surface – don’t place on un-compacted fill Pack subsoil with hand tamper or mechanical compactor Place a level foundation: –Ground-contact-treated lumber box, filled with 6 inches of 3/8 crushed rock, well compacted. May top with 1 inch of sand or fine gravel to get smooth level surface under cistern. –Concrete blocks or heavy (min. 3-inch thick) pavers – perfectly level on top –Existing concrete pad, if level. (Installing a new concrete pad would require a building permit.)

16 Seattle Public Utilities16

17 Seattle Public Utilities17

18 Seattle Public Utilities18 Step 2: Place cistern tank Don’t block opening of doors & windows, emergency egress, vents, utilities access, etc. Plan for downspout flow to cistern, and overflow routing Consider appearance and consult neighbors Follow manufacturer’s instructions If the tank is taller than it is wide, secure for earthquake safety (usually impractical, so best not to use tall, narrow tanks) Downspout Screened inlet Overflow Drain to garden hose

19 Seattle Public Utilities19 Connect additional tanks, if used

20 Seattle Public Utilities20 Step 3: Install screened inlet, to keep debris and mosquitoes out At minimum, wrap and secure aluminum screen over inlet opening Additional protection against clogging: –Gutter screens and wire cages in gutter outlets to exclude leaves –Self-cleaning leaf excluder in downspout run to cistern – commercially available or home- assembled – Google “Downspout filters, screens” –Divert dirtier initial flow after dry period: Google “First flush diverters” “Roof washers” or “Cistern Installation” for ideas

21 Seattle Public Utilities21

22 Seattle Public Utilities22

23 Seattle Public Utilities23

24 Seattle Public Utilities24 Step 4: Make gutter connections 3-4” Aluminum, ABS, or PVC NDS pipe Secure all connections with stainless steel screws & silicone seal, or glue Strap & support as needed May put a self-cleaning leaf excluder in line: typically a sloped screen so leaves are pushed aside Arrange so water falls into screened inlet, with access to clean screen

25 Seattle Public Utilities25 Step 5: Install overflow pipe that’s as big as the inlet pipe Watertight bulkhead fitting at top, or internal overflow riser, or both (if less that 3 inch) Must be big enough to carry full gutter flow once cistern fills – Install “P” trap somewhere, to prevent mosquito and rat entry

26 Seattle Public Utilities26 Step 6: Extend overflow pipe to a safe discharge point 5’ from house or 10’ if basement 5’ from property line, 10’ from neighboring buildings Rubber “hubless” unions protect against breakage, allow maintenance Use rocks or gravel to prevent erosion and disperse overflow into landscape If reconnected to sewer, requires a permit – call DPD

27 Seattle Public Utilities27

28 Seattle Public Utilities28

29 Seattle Public Utilities29 Consider appearance Can screen cistern with fencing, latticework, cedar or bamboo wrap, etc. Plastic paint works on ABS & PVC pipe Blend with existing architectural finishes Consult with neighbors South Seattle Community College cistern overflowing to rain garden in a downpour, Nov. 2009

30 Seattle Public Utilities30

31 Seattle Public Utilities31

32 Seattle Public Utilities32

33 Seattle Public Utilities33

34 Seattle Public Utilities34

35 Seattle Public Utilities35

36 Million Dollar Idea: Chia-Tank

37 I wanna rock! Seattle Public Utilities37

38 Seattle Public Utilities38 Step 7: Install drain valve for use as “low-flow orifice” Use oversize (1-3”) bulkhead fitting, so entire fitting can be removed for cleaning tank. Or install separate cleanout plug. “Hose bib” garden hose faucet Connect garden hose, and run it to safe discharge point to drain cistern slowly between storms Close faucet in May to store water for summer. Open again in October to detain and slowly drain winter storm water

39 Seattle Public Utilities39

40 Seattle Public Utilities40

41 Installation Statistics 2010: 17 installations 2 cistern, 9 rain garden, 6 combo 2011: 78 installations 7 cistern, 57 rain garden, 14 combo 2012: 114 installations 14 cistern, 76 rain garden, 24 combo 2013: 123 installations 15 cistern, 81 rain garden, 27 combo Seattle Public Utilities41

42 Questions? Guide, factsheets, and design tools: www.seattle.gov/util/RainWise www.seattle.gov/util/RainWise RainWise Tools www.rainwise.seattle.gov Bob Spencer David McDonald Seattle Public Utilities