Download presentation
Presentation is loading. Please wait.
Published byMilton Greener Modified over 9 years ago
1
Pipe Condition Flags
2
Purpose of Culvert Inspections Identify bad pipes to be replaced during scheduled highway project. Reduce the incidence of road failures from deteriorated pipes.
3
Inspection Basics Inspection Codes: 1 = Good as new condition 2 = Some wear, but structurally sound 3 = Extensive deterioration, consider for repair or replacement 4 = Critical deterioration 0 = Not rate-able
4
CMP culvert distortion and deterioration
5
TH 95 at MP 80 HYDINFRA Inspection Terms
6
Pipe Inspection Flags Needs Clean? Needs Clean? Needs Repair? Needs Repair? Standing Water Standing Water Erosion Erosion Plugged Plugged Silt Silt Cracks Cracks Pitting/Rusting Pitting/Rusting Spalling/Flaking Spalling/Flaking Piping Piping Misalignment Misalignment Joints Separated Joints Separated Holes Holes Deformation Deformation Inslope Cavity Inslope Cavity Void in Road Void in Road Road Distress Road Distress Repair under Road Repair under Road
7
Structure Inspection Flags Needs Clean? Needs Clean? Needs Repair? Needs Repair? Standing Water Standing Water Spalling/Flaking Spalling/Flaking Pitting/Rusting Pitting/Rusting Cracks Cracks Holes Holes Ring Deterioration Ring Deterioration Void in Road Void in Road Road Distress/Deformation Road Distress/Deformation
8
Special Structure Inspection Flags Needs Clean? Needs Clean? Needs Repair? Needs Repair? Standing Water Standing Water Spalling/Flaking Spalling/Flaking Pitting/Rusting Pitting/Rusting Deteriorated Ties Deteriorated Ties Joints Separated Joints Separated Deformation Deformation
9
Road Distress
10
Pavement and guardrail indicate problem here
11
Special Structure: Headwall Condition 4 Flag for Repair Joint Separation (from pipe)
12
Pipe (plus 2 special structures– Bend and Reducer): Bend Reducer 48” to 36” Pipe Size 36” Holes Piping Pitting/Rusting Spalling/Flaking
13
Misalignment Pipe: Condition 4 Flags: Repair Pitting/Rusting Spalling/Flaking Holes Piping
14
Pipe: Deformation Separation Misalignment
15
Pipe: Holes Silt Pitting/Rusting Spalling/Flaking Deformation Piping
16
(second pipe above 36” cmp)
18
36” Pipe: Separation Inslope Cavity (hole in soil above pipe) 12” Pipe Flume: Condition 2 ?
19
Misalignment Joints Separated Infiltration
20
Erosion – Channel Degradation Banks are slumping into channel
21
Erosion – Channel Degradation
22
Special Structure: Headwall Condition 4 Repair Joints Separated Deformation Pitting/Rusting 12” CMP with Apron: Condition 2 ? (but installation should be noted in comments) Energy Dissipater? Pipe: 36” CMP Condition 4 Inspection Flags: Repair Pitting/Rusting Spalling/Flaking Erosion Piping Misalignment Joints Separated Holes Deformation Infiltration Inslope Cavitation Void in Road Road Distress/Deformation