1
EZ-SCREEN ® LP with Integral Muting
2
Introduction ■ No “third box” muting controller required –Simple design & lower installed cost ■ Many of the same features as a standard EZS Low Profile (e.g. Scan codes, Reduced Resolution, Fixed Blanking) –No cascading, No 270 mm model ■ Same list prices as Cascade Receivers –$72 adder from standard EZS LP –Uses standard EZS LP emitters
3
Muting Configurations Seven Pre-Defined Muting Configurations ■ Maximum Mute Cycle Time (Infinite or 60 sec) ■ Bypass or Mute Dependent Override ■ Mute Enable options ■ “L” configuration Exit Application (option #7)
4
Muting Configurations, cont. ■ Bypass: Force the OSSDs to turn ON or stay ON at anytime (other than during a lockout) ■ Mute Dependent Override: The defined area must be blocked and one or both Mute Inputs must be active to start the override (turn ON the OSSDs)
5
Muting Configurations, cont. ■ Mute Enable selection allows for “Directional” or “One-way” muting –Requires an additional device to “window” when a mute can begin
6
Muting Configurations, cont. “L” Configuration Exit Application ■ “Holds” mute ON for 4 seconds ■ Both sensors on the hazardous side ■ Another means of Directional/One-way muting
7
Configuration and Indicators ■ Configured via DIP-switches –Similar steps as configuring a cascade system –T, RR off, L, RR on and then toggle “invert” switch –Configuration number displayed –No PC or hand-held device ■ Easy to see Status, Reset, Zone, Mute Device and Diagnostic indicators and displays –M1 and M2 Mute Input indicators
8
Receiver Inputs and Outputs ■ Normally open Reset / Override1 Input. ■ Normally closed Override2 / Mute Enable Input ■ 1-Channel External Device Monitoring (EDM) ■ 2x Mute Device Inputs (PNP or Normally Open contacts) ■ 2x OSSDs, +24Vdc / 500 mA each ■ AUX Output, +24Vdc / 250 mA (OSSD-follow / Fault) ■ Mute Lamp and status outputs (at the “top” end) –Mimics receiver indicators
9
Mute Cycle Indicators ■ Mute Lamp & Status Outputs –Mounting bracket & DELPEF cordset ■ EZ-LIGHT ® indicators –Standard 1-color –TL50GYRWQ 4-color Tower –K50LGRW2PQ-18886
10
Receiver Hookup Options ■ RD cordsets (11 conductor/flying leads) ■ M12/Euro 12-pin QD cordsets
11
Receiver Hookup Options, cont. ■ CSMxxx Muting Splitter QD Cordsets –M1 and M2 mute sensor inputs –Dark and Light Operate models –Three branch to connect sensors and receiver –Four branch to connect “P8” emitter –Use with “P12” receivers or DELPE-12xE cordset
12
Application Example #1 “X” – Pattern Entry/Exit ■ Excellent solution
13
Application Example #2 Entry/Exit Application using four pairs of sensors ■ Parallel M1 & M4 (Input #1) and M2 & M3 (Input #2)
14
Application Example #3 “L” Configuration Exit Application ■ Mute-cycle time extension (4 seconds)
15
Application Example #4 Robot Operator Load/Unload
16
Summary ■ “EZ” setup and installation ■ Built-in muting function, no third box required ■ Seven muting configurations –E.g. “L” configuration Exit Application ■ Mute Lamp and Status Outputs to EZ-LIGHT ■ 1-Ch External Device Monitoring ■ DIP switch configurable; No PC or Hand-held device ■ Many of the same features as a standard EZS LP ■ 14 or 25 mm resolution, 410 to 1810 mm defined areas