Download presentation
Published byDesiree Hough Modified over 10 years ago
1
CCS 800 Ultro - the discussion system with digital acoustic
feedback suppression CCS800 Ultrol
2
Why a change ? Request from the market:
Less susceptible from acoustic feedback Increase the volume Push sales: Mention the rights messages Increase perceived value by design update Discover latent needs Town halls Enterprises CCS800 Ultrol
3
The discussion system with digital acoustic feedback suppression !
CCS 800 Ultro Ultro is Latin for: Something extra The discussion system with digital acoustic feedback suppression ! CCS800 Ultrol
4
Gives full control over all types of discussion
Good speech intelligibility for all participants Speeds up a meeting process Chairman is in control One central meeting CCS800 Ultrol
5
Excellent speech intelligibility for all participants’’
Optimal acoustic and electrical design Number of Open Microphones (NOM) dependent gain control Headphone facility per microphone unit External audio equalizer connection available CCS800 Ultrol
6
Built-in digital acoustic feedback suppression facility
Normal Acoustic Feedback Limit System Gain Unity Gain Ultro Acoustic Sound Pressure level CCS800 Ultrol
7
Attractive, unobtrusive design
CCS800 Ultrol
8
Several operating modes for real flexibility in discussion management
4 different types of operating modes Open mode Open mode with auto switch off Override mode Chairman only mode CCS800 Ultrol
9
Suitable for fixed or temporary installations
permanent or temporarily installation suitcases available no tools needed transportable CCS800 Ultrol
10
Easily extendable Up to 150 microphone units One master CPSU’s
Two slave CPSU’s 50 units Master 50 units Slave 50 units Slave CCS800 Ultrol
11
Product overview CCS800 Ultrol
12
Delegates Units Two different stem lengths Built in loudspeaker
Microphone LED ring indicator Double headphone connection with volume control Product variants LBB 3330/00 LBB 3330/50 CCS800 Ultrol
13
Delegates Units 1. Mic. With red LED ring 2. Headphone sockets
3. Loudspeaker 4. Mic. On LED indication 5. Loop through connection 6. Connection cable 2 meter 7. Volume control 8. Microphone ON / Off push-button CCS800 Ultrol
14
Delegates Units 1. Microphone with red illuminated indicator ring, lights when the microphone is ON. 2. Two 3.5 mm stereo headphone sockets, one at each side, for headphone or recorder connection. Insertion of a headphone jack in one or both sockets automatically mutes the unit’s loudspeaker. 3. Built-in loudspeaker, automatically muted when the microphone is on. 4. Red (LED) indicator above the microphone push button, for microphone ON indication. 5. 7-pole circular female socket for loop-through connection to the next unit. 6. 2m flying lead connection cable with sturdy moulded 7-pole circular male connector for connection to the previous unit or CPSU. 7. Rotary volume control for headphones only. 8. Microphone ON/OFF push-button. CCS800 Ultrol
15
Chairman's Units Same features as delegate unit
Priority button and chime signal possibility to switch off chime tone temporary or permanently muting all active microphones Product variants LBB 3331/00 LBB 3331/50 CCS800 Ultrol
16
Chairman's Units 5. Loop through connection
6. Connection cable 2 meter 8. Mic. ON / OFF push-button 9. Priority push-button CCS800 Ultrol
17
Chairman's Units 1. Microphone with red illuminated indicator ring, lights when the microphone is ON. 2. Two 3.5 mm stereo headphone sockets, one at each side, for headphone or recorder connection. Insertion of a headphone jack in one or both sockets automatically mutes the unit’s loudspeaker. 3. Built-in loudspeaker, automatically muted when the microphone is on. 4. Red (LED) indicator above the microphone push button, for microphone ON indication. 5. 7-pole circular female socket for loop-through connection to the next unit. 6. 2m flying lead connection cable with sturdy moulded 7-pole circular male connector for connection to the previous unit or CPSU. 7. Rotary volume control for headphones only. 8. Microphone ON/OFF push-button. 9. Chairman Priority button. When pressed emits chime tone, overrules/mutes all active microphones of delegate units in the system and keeps the chairman's microphone on for as long as the button is pressed (default setting can be changed in the chairman unit, see next slide). In systems with several chairman units these settings are independently selectable for each chairman unit. CCS800 Ultrol
18
Priority button settings
Chime switch ‘0’ = no chime ‘1’ = chime (default ) Microphone Mute ‘0’ = delegate mic. Permanently off at priority ‘1’ = delegate mic. Temporary off at priority CCS800 Ultrol
19
Control and Power Supply Unit
Test facility for proper connection Appearance in line with units Mounting possibilities table top 19” rack flush mounted Built in loudspeaker Product variants LBB 3310/00 LBB 3310/10 (DAFS) CCS800 Ultrol
20
Control and Power Supply Unit
System functions and modes Microphone modes Open mode with auto switch off Open mode Override mode Chairman only mode Volume control facility for system loudspeakers Monitoring volume control Headphone connection CCS800 Ultrol
21
Control and Power Supply Unit
1. Mains On/Off switch 2. Power On LED (green) 3. Microphone-mode switch 4. Speaker volume control 5. Volume control of the loudspeaker or headphone of the CPSU 6. Headphone socket CCS800 Ultrol
22
Control and Power Supply Unit
1. Mains On/Off switch. 2. Power On LED indicator (green). 3. Microphone-mode switch. Open mode with auto switch-off. To select the maximum number of delegate microphones to be activated simultaneously (1, 2, 3 or 4). The microphone automatically switches off if the speaker does not speak for 30 seconds. The microphone can manually be switched off by pushing the button on the delegate unit. Open mode. To select the maximum number of delegate microphones to be activated simultaneously (1, 2, 3 or 4). The microphone must be switched on or off manually by pushing the button on the delegate unit. Override mode. Only one microphone can be activated. If a new delegate presses his microphone button, the microphone unit of the current speaker will be switched off. Chairman only mode. Only chairman units can be activated. Test mode. For proper installation check. All the light-rings and LED’s of the connected units will lit, if properly connected. 4. Speaker volume control of all connected delegate and chairman units. 5. Volume control of the speaker or headphone of the CPSU. 6. Headphone connection with 3.5 mm stereo jack plug socket. CCS800 Ultrol
23
Control and Power Supply Unit
Switch on DAFS facility Two trunk lines External Microphone Recorder PA system Telephone coupler Equalizer Mains CCS800 Ultrol
24
Control and Power Supply Unit
7. Trunk output 1 and 2 8. External microphone input. 9. Recorder input and output connection. 10. Line input and output. 11. Telephone coupler 12. Insertion connection 13. DAFS 14. Mains socket CCS800 Ultrol
25
Control and Power Supply Unit
7. Trunk output 1 and 2. For loop-through connection of the delegate and chairman units. To each output a maximum of 25 units can be connected. The maximum length of cable between the outputs of the CPSU and the last unit in the system is 100 m (328 ft). 8. Microphone input with gain adjustment for external microphone. The external microphone will be muted when the priority button on the chairman unit is pressed. 9. Recorder input with gain control and recorder output connection. 10. Line input and output for connecting a PA-system or other audio equipment. 11.Telephone coupler input and output for connecting a remote participant. Note: The telephone input signal to the CPSU is not added to the telephone output signal from the CPSU to prevent line echo due to feedback. 12. Insertion connection. To connect an external audio equalizer for speech quality improvement under difficult acoustic conditions (1=without equalizer, 0=insertion connection is internally open, providing means to connect an external equalizer in the path from microphone signals to delegate/chairman loudspeakers). Note: Position "1" required for internal loop-through of the microphone signals to the delegate / chairman unit loudspeakers. 13. Mains input connection. Use the included mains cord to connect the CPSU to the mains socket. CCS800 Ultrol
26
Mounting brackets Set of 19” rack mounting brackets LBB 3311/00
CCS800 Ultrol
27
Trunk Cables Extension cables with molded connectors
5 M extension cable, LBB 3316/05 10 M extension cable, LBB 3316/10 25 cable clamps, LBB 4117/00 100M of installation cable with 5 male and 5 female connectors, LBB 3316/00 CCS800 Ultrol
28
Suitcase Up to 10 positions delegate or chairman's units with short microphone stem, LBB 3312/00 Up to 6 positions for delegate or chairman's units with long or short microphone stem and one Control Power Supply Unit (CPSU), LBB 3312/10 CCS800 Ultrol
29
Headphones LBB 3441/00 Under the chin Mono 50 Hz - 5KHz (-10dB)
max. power 60mW LBB 3442/00 Single earphone 100 Hz - 5kHz (-10dB) Max. power 5mW CCS800 Ultrol
30
Headphones LBB 3443/00 Stereo headphone 50Hz - 20kHz (-10dB)
max. power 50mW LBB 3015/04 250 Hz - 13KHz (-10dB) max. power 200mW CCS800 Ultrol
31
Application Examples CCS800 Ultrol
32
City Council Meeting CCS800 Ultrol
33
City Council Meeting Active participants will have a table top unit
Audience will have an external microphone. Multi lingual facility via wireless Digital Infra-red Language Distribution, Integrus Teleconference via an optional telephone coupler CCS800 Ultrol
34
Courtroom CCS800 Ultrol
35
Courtroom Participants listen and speak via a table top unit.
Facility for recording the entire proceeding. A public address system (Plena product range) is connected for the benefit of the public gallery. Optional video conferencing. CCS800 Ultrol
36
CCS 800 Ultro - the discussion system with digital acoustic
feedback suppression CCS800 Ultrol
37
End of CCS800 Ultro Presentation
Robert Bosch GmbH All rights are reserved. Reproduction in whole or in parts is prohibited without the written consent of the copyright owner CCS800 Ultrol
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.