27/02/2002M.D.P. - ATLAS Muon Week1 First results of Atlas RPC cosmic rays test Massimo Della Pietra Atlas RPC Group Napoli ( M. Alviggi, V. Canale, M. Caprio, G. Carlino, F. Conventi, R. de Asmundis, M.D.P., D. della Volpe, P. Iengo, S.Patricelli, L.Romano, G. Sekhniaidze )
2
27/02/2002M.D.P. - ATLAS Muon Week2Outline RPC cosmic rays test in Naples. Definitions. Test results. Gap currents and single rates Full Plateau curves Cluster size Conclusions.
3
27/02/2002M.D.P. - ATLAS Muon Week3 RPC Test in Naples First chamber under test in Naples: BOS-B-004. final receivers 32 strips or 32 strips were tested with cosmic rays using final receivers. A complete scan of RPC performances with respect to HV and threshold values has been done.
4
27/02/2002M.D.P. - ATLAS Muon Week4 Splitter board Shaper (50 ns) Latch Scaler TDC Shaper (50 ns) VME DAQ Setup Splitter board
5
27/02/2002M.D.P. - ATLAS Muon Week5 Gap currents
6
27/02/2002M.D.P. - ATLAS Muon Week6 Single rates
7
27/02/2002M.D.P. - ATLAS Muon Week7 Single rates
8
27/02/2002M.D.P. - ATLAS Muon Week8 Definitions (I) 10000 muons have been triggered for each run with fixed HV and threshold. golden To evaluate the RPC performances golden tracks were selected (1 single hit for each layer in drift chambers) reducing the sample to about 5000 events.
9
27/02/2002M.D.P. - ATLAS Muon Week9 Definitions (II) Expected strip Expected area The RPC is considered to be efficient if there is an hit in the “expected area” (defined as the expected strip 5 mm).
10
27/02/2002M.D.P. - ATLAS Muon Week10 Definitions (III) Non physical cluster Physical cluster We define Physical Cluster as the set of contiguous strips containing the expected one.
11
27/02/2002M.D.P. - ATLAS Muon Week11 Plateau efficiency: ~ 96% Plateau efficiency: ~ 96% TDC e LATCH results are identical within 0,1 % TDC e LATCH results are identical within 0,1 % HV normalized HV normalized @ 1013 mbar, 20.5ºC strips: Efficiency vs. HV
12
27/02/2002M.D.P. - ATLAS Muon Week12 strips: Efficiency vs. Threshold Plateau efficiency: ~ 96% Plateau efficiency: ~ 96% TDC e LATCH results are identical within 0,1 % TDC e LATCH results are identical within 0,1 % HV normalized HV normalized @ 1013 mbar, 20.5ºC
13
27/02/2002M.D.P. - ATLAS Muon Week13 Mean N. of Clusters 1.01 @ (0.71mV,10500 V) Mean N. of Clusters 1.01 @ (0.71mV,10500 V) HV normalized HV normalized @ 1013 mbar, 20.5ºC strips: N. of Clusters
14
27/02/2002M.D.P. - ATLAS Muon Week14 Phys. cluster size 1.3 @ (0.71mV,10500 V) Phys. cluster size 1.3 @ (0.71mV,10500 V) HV normalized HV normalized @ 1013 mbar, 20.5ºC strips: Cluster size
15
27/02/2002M.D.P. - ATLAS Muon Week15 Plateau efficiency: ~ 96% Plateau efficiency: ~ 96% TDC e LATCH results are identical within 0,1 % TDC e LATCH results are identical within 0,1 % HV not normalized! (DCS problem.) HV not normalized! (DCS problem.) strips: Efficiency vs. HV
16
27/02/2002M.D.P. - ATLAS Muon Week16 Plateau efficiency: ~ 96% Plateau efficiency: ~ 96% TDC e LATCH results are identical within 0,1 % TDC e LATCH results are identical within 0,1 % HV not normalized! (DCS problem.) HV not normalized! (DCS problem.) strips: Efficiency vs. Threshold
17
27/02/2002M.D.P. - ATLAS Muon Week17 Mean N. of Clusters 1.05 @ (0.59mV,10500 V) Mean N. of Clusters 1.05 @ (0.59mV,10500 V) HV not normalized! (DCS problem) HV not normalized! (DCS problem) strips: N. of Clusters
18
27/02/2002M.D.P. - ATLAS Muon Week18 Phys. cluster size 1.4 @ (0.59 mV,10500 V) Phys. cluster size 1.4 @ (0.59 mV,10500 V) HV not normalized! (DCS problem) HV not normalized! (DCS problem) strips: Cluster size
19
27/02/2002M.D.P. - ATLAS Muon Week19 Both curves reach 96% of efficiency Both curves reach 96% of efficiency HV not normalized to compare the two curves ! HV not normalized to compare the two curves ! and Efficiency
20
27/02/2002M.D.P. - ATLAS Muon Week20 and Cluster size strips are a little noisier than strips (under investigation). strips are a little noisier than strips (under investigation). HV not normalized to compare the two curves ! HV not normalized to compare the two curves !
21
27/02/2002M.D.P. - ATLAS Muon Week21Conclusions The results show a good RPC behavior for both and plane: Efficiency 96 % Cluster size 1.3 - 1.4 TDC and LATCH give identical results with shaped signals. The analysis tools to fully test up to 8 RPCs together are ready. We’re ready for massive tests. @ working point.