Presentation is loading. Please wait.

Presentation is loading. Please wait.

Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD Computer GmbH & Co.KG 2009.

Similar presentations


Presentation on theme: "Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD Computer GmbH & Co.KG 2009."— Presentation transcript:

1 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD Computer GmbH & Co.KG 2009

2 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Installation MCPS 1 -Insert MCPS installation-CD (If Auto start is disabled, please run Start.exe from the MCPS installation-CD.). -Click “Info Tour” to get common information about MCPS. -Click “Installation” to install the MCPS software.

3 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Installation MCPS 2 - Select language and confirm with “OK”

4 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Installation MCPS 3 - On Welcome-window click “Next” to continue installation.

5 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Installation MCPS 4 - Select kind of installation: - Installation as measurement – PC - Installation as NetView-Client – PC - Installation as Demo version

6 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Installation MCPS 5 - Read license agreement and accept the agreement with a click on “Accept”.

7 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Installation MCPS 6 - Select directory to install the MCPS – software.

8 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Installation MCPS 7 - Insert adequate password if available. - Leave this field empty if no password is available MCPS will be installed as demo-version. - It is possible to add a password later.

9 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Installation MCPS 8 Waiting while MCPS is being installed

10 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Installation MCPS 9 / Start MCPS - Information about the successful installation of the MCPS – Software, click “OK” - Double-click on the MCPS-icon on your desktop to start MCPS-software

11 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Device manager 1 - Click, to open the device manager. Device manager

12 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Device manager 2 - Click to add a new device. - Select a new device in the Add device window. (MW100 in this example.) Add device window

13 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 MW100 setup window Device manager 3 a) Select interface d) Test connection g) Make memory card settings c) Reconstruct after change of module(s) b) Set hardware sample rate(s) e) + f) detects existing Modules on the Device and compares current configuration

14 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Device manager 3 a) Select kind of interface Set COM-port number and make modifications to the RS232 port of the PC if necessary. Select RS422 Device address. Set Bus-address for the GPIB-interface Set IP-address for Ethernet-interface Device connection Timeout Number of retries before Timeout message occurs.

15 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Device manager 3 b) Yokogawa MW 100 and MX 100 are able to use modules with different sample rates: Standard modules fastest sample rate 100ms Fast modules with sample rates up to 10ms. Select the required sample rates if different modules are installed.

16 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Device manager 3 c) If MW 100 / MX 100 is used for the first time OR when modules are changed, it is required to run Reconstruct before new installed modules can be used. ATTENTION: All settings concerning Mode, Range, a.s.o. are lost after a “Reconstruct”! You have to setup the MW 100 / MX 100 recent.

17 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Device manager 3 d) Make a test of the connection between PC and MW100/MX100 using the button “Test device” before you start using the MW100/MX100. If connection is OK, you’ll see a message like below:

18 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Device manager 3 e) Next important step after successful connection test: Run “Auto detect” “Auto detect” verifies the current module configuration with the existing modules on the Device.

19 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Device manager 3 f) If different configuration is detected by “Auto detect”, physical existing Modules are automatically updated in the configuration screen.

20 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Device manager 3 g) Enable/disable data backup on the Compact Flash card. Format Compact Flashcard before usage. See common information about the Compact Flash card

21 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Click, or click the Icon in the menu-line to create a new, empty project. Create new project step 1

22 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Create new project step 2 Project configuration window Project configuration Select your sample rate Select your deviceSelect a channel of your device Add one or a selectable number of channels Delete one or a number of marked channels Save your project settings Type in a tag Type in a comment

23 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Project configuration window Create new project step 3 Project configuration Enable / Disable mathematical calculation Fill in mathematical formulas as (X1-X2)*SIN(X3) Select YMin and YMax for trend display Select number of decimal places Select if channel should be displayed in numeric / trend /digital display Select kind of marker in the trend display

24 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Create new project step 4 Or Click on Main Menu Bar, Add a message which is displayed in the online alarm window Add a SMS-text which is send in case of an alarm. Add an E-Mail which is send in case of an alarm. Add a script which is proceeded in case of an alarm..

25 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Create new project step 5 Configure a channel alarm. Click on “Alarm” in the project configuration. Click here to configure the alarm actions Select type of alarm: - High alarm - Low alarm -Differential high alarm -Differential low alarm -a.s.o.

26 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Create new project step 6 Alarm actions Select up to 5 different alarm actions per alarm level. MCPS stops active measurement in case of an alarm. Activates digital output when an alarm is acknowledged.

27 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Mathematic Use basic mathematical functions as - Plus+ - Minus- - Multiply* - Divide/ - Exponentiation^ Enable mathematical calculation for the corresponding channel Fill in a mathematical formula (X1+X2-X3)^2

28 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Save a new project Typical project configuration Save your project configuration and click to start the measurement.

29 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Statistic Use statistical functionality to get information about MIN-, MEAN-, MAX-values, about standard deviation and MKT of all interesting channels. Click, to get these information.

30 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Display Trend Trend window

31 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Display Numeric Numeric window

32 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Display Solo Solo window: Digital or analogue display Solo-window digital Solo-window analogue

33 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Display Profile Profile window: Profile-window

34 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Window manager 1

35 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Window manager 1 Window manager: Stores the arrangement of numeric, graphic and solo windows together with local settings of above windows. Click,, to store the current window configuration for subsequent use.

36 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Window manager 2 To recall the saved window layouts click,, or use icon.

37 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Report / Print layout 1 To generate all-embracing reports of measured data, MCPS contains a powerful Print layout tool. Click,

38 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Report / Print layout 2 Create a new layout Open an existing layout Save changed / new layout Switch between sides Change displayChange grid resolution Select item Add output frame Add text field (Use control codes!) Add input field Open online help Delete item Move item to front or back Copy item Change font of text items Change properties of an item Add legend Add bitmap

39 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Report / Print Layout 3 Result Layout

40 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Appendix: Control Codes for Print layout 1 Available control codes for print layouts $PN Project name $RNAutoFile record $COCompany name $GRGroup $OPOperator $DATEDate of printout $TIMETime of printout $PI(1)1. Line of comment rows in PROJECT INFORMATION.. … … $PI(10)10. Line $PX(1)1. Line of additional information $PV(xxx)Value of the project variable xxx. $PSStart time of project data (1. data scan) $PEEnd time of project data (last data scan) $PDDuration of measurement (End time – Start time) $UCn(chn)Contents of user column n of channel chn in the project configuration $LUNCurrent login user name $LUICurrent login user id $LUCComment of current login user After a statistical computation the following variables are set and can be used for the printout: $SnMIN Minimum value of channel n $SnMAX Maximum value of channel n $SnMEAN Mean value of channel n $SnSTD Standard deviation $SnMKTMKT $SnFxMINFormating statistic data: -> F = Format, x = 0-6 decimal places, n = Channel number

41 Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD-Computer GmbH & Co.KG 2009 Appendix: Control Codes for Print layout 2 Available control codes for print layouts $SSDStart date of statistic run $SEDEnd date of statistic run $SSTStart time of statistic run $SETEnd time of statistic run $SBCNumber of evaluated scans Codes for batchfiles: $BAbatch (base name as shampoo) $BNbatch name (full name as shampoo-001-020602) $BLlot number $BPrelated project $BSbatch start time $BEbatch end time $BDbatch duration $BUbatch unit $BI(n)additional input info n of the batch mask (e.g. serial number) $BV(n)related value (input by user) $BXSnlevel n(1-3): signed / not signed $BXTnlevel n: time of signing $BXCnlevel n: comment for signing $BXUnlevel n: user, who has signed $BXInlevel n: user-id $BXDnlevel n: description


Download ppt "Copyright © CAD-Computer GmbH & Co. KG January 2009 All rights reserved, property and © CAD Computer GmbH & Co.KG 2009."

Similar presentations


Ads by Google