Introduction World Top Class FCX-AIII The FCX Series transmitters were introduced in 1989 and have an installation base of more than 1 million. FCX-AIII Series is the latest transmitter model which demonstrated improved accuracy and long-term stability. The FCX-AIII provides superior reliability, user-friendly, expansion menu function, reduced size & weight. Friday, May 01, 2015
4
Reliability & Stability Friday, May 01, 2015
5
Seal Diaphragm for Corrosive & Hydrogen Penetration Friday, May 01, 2015
6
Various Type of Diaphragms High Temperature & Vacuum Transmitters High Temperature up to 300 ˚C DP Type can withstand Static Pressure up to 1,035barg Friday, May 01, 2015
7
Excellence Performance with High Accuracy Up to 0.04% as an option and Standard 0.065% * *Applicable even on low differential range (1kPa). This is exceptional feature of Fuji Electric transmitter and not available with other manufacturers. Extra Long Term Stability ± 0.1% for 10years Friday, May 01, 2015
8
Comparison on Accuracy Friday, May 01, 2015 8 3051S DP250kPa EJX DP100kPa Spec ±0.065% Spec±0.04% FCX-AIII GP130kPa FCX - AIII DP32kPa Spec ±0.065% Test Data on Zero Drift of URL Note) Test Conditions: 1 st to 10 th Day: at 20˚C constant 11 th to 19 th Day: at 20˚C after 0~40˚C Temperate Cycles Everyday Better performance than competitors’ models Maximum Error(%) 0 -
9
Response Time with FCX-AIII Amplifier Friday, May 01, 2015 –Update Time: 60ms –Dead Time Min/Max : Reduced from 200/290ms to 100/145ms –Time Constant at 63% output: Min 60ms (Depends on model & Range) –Response Time at 63% Output: Dead Time + Time Constant = 160/205ms –(Example) 130kPa GP: Dead time Input Pressure Source (From 100kPa to 0kPa) Output of FCX-A Ⅲ 115ms60ms 63%
10
Configuration & Maintenance Tools Friday, May 01, 2015
11
Enhanced Configuration & Maintenance Tools Friday, May 01, 2015 Field configuration by 3 push-buttons on LCD Indicator Mode Switch Up Switch Down Switch Display of PV (Normal) 1. Zero Adjustment 2. Span Adjustment Parameter Change Functions of 3 Push Buttons
12
Conformity to Various International & Approvals Friday, May 01, 2015
13
Configuration & Maintenance Tools Friday, May 01, 2015
14
Lineup of L & T Type Housing Friday, May 01, 2015
15
Specifications Friday, May 01, 2015
16
Accessories Friday, May 01, 2015
17
The End Friday, May 01, 2015