Download presentation
Presentation is loading. Please wait.
Published byEmily Putnam Modified over 9 years ago
1
WELCOME
2
Controllers
3
Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs, combination of Relay/Relay, Relay/SSR, SSR/SSR. Full Heat/cool algorithm Output power OFF function Soft start function (timed output power limiting). Loop break alarm function (Alarm of anomalous condition in the control loop). Switching power supply (from 100 to 240 V AC or 24 V AC/DC). CE approved for residential and industrial environment. IP 65 and NEMA 4X front protection
4
1/16 DIN 3 & 4 digit temperature controllers LDE - LME Dual 3 digit display or single 4 digit display. T/c or Pt100 input. Up to 3 outputs (3 relays or SSR +2 relays). Full Heat/Cool Algorithm. Multi function process timer with logic input. Built in configuration port. Process, band, deviation or instrument malfunction alarm. Soft start function (timed output power limiting). Output power OFF function. Programmable offset on the measured value. IP 65 and NEMA 4X front protection
5
1/16 DIN Dual display 4 digit controller LFS relay Load current measurement (in Amps) with output failure alarm, all by use of CT input. Universal input Outputs- 3 relays or SSR + 2 relays 1 logic input for setpoint selection: SP1 or SP2 SMART tune Soft start function (timed output power limiting). Output power OFF function. RS-485 communication interface option. Rear-of-board version: DIN rail mounting IP 65 and NEMA 4X front protection.
6
1/16 DIN Dual display 4 digit controller LFS mA Isolated 20 mA linear output programmable as: - control output - analog retransmission of the measured value. - analog retransmission of the operative set point. Analogue output + 2 relays as standard. 2 logic inputs. RS-485 serial communication interface. Rear-of-board version. IP 65 and NEMA 4X front protection.
7
1/16 DIN 4 digits Servo motor controller LFS Servo 4 relay outputs made up as follows: 1 & 2 Servo motor outputs 3 & 4 Dual alarms Inputs T/c or linear main, Feed back pot auxiliary Full servo and heat/cool algorithms. RS-485 serial communication interface. Rear-of-board version. IP 65 and NEMA 4X front protection.
8
1/16 DIN 4 HOT RUNNER controller LFS S03 Application specific controller for the Plastics industry. Full Heat/Cool algorithm Digital set point retransmission Soft start functionality with output fail detection RS-485 serial communication interface. Sensor fail detection with power safety level IP 65 and NEMA 4X front protection.
9
1/4-1/8 DIN Controllers with universal input MKS - TKS relay Universal input plus logic input CT input allowing load current measurement (in Amps) with output failure alarm. Loop break alarm function (Alarm of anomalous condition in the control loop). 4 outputs RS485 serial communications IP 65 and NEMA 4X front protection. Out 1: Relay or SSR output selectable
10
1/4-1/8 DIN Controllers with universal input MKS - TKS mA Isolated 20 mA output programmable as: - control output - analog retransmission of the measured value or the operative set point. 3 additional relay outputs 2 logic inputs 24 V DC auxiliary power supply for transmitters. RS485 serial communications Four set points selectable by external contacts. IP 65 and NEMA 4X front protection. Linear output
11
1/4-1/8 DIN Controllers with universal input MKS - TKS Servo Control output programmable as servomotor drive or time proportional output. Programmable open or close loop servomotor control. Four set points selectable by external contacts. Three logic inputs for the selection of: - the operative set point - AUTO/MANUAL mode - the DIRECT/REVERSE action. AUTO/MANUAL transfer with programmable valve positioning. RS485 serial communications IP 65 and NEMA 4X front protection. Servomotor output
12
1/4-1/8 DIN High performance controllers MKC - PKC Up to 4 independent digital outputs programmable as control outputs, events or alarms. Up to 2 independent analog outputs programmable as control outputs or analog retransmission's. Pre-programmable output for the linearisation of equal percentage or quick opening valves. Split range of the output function. Alarms on the control output percentage. Load current measurement (in Amps) with output failure alarm. Three programmable logic inputs. Remote set point input. 24 V DC auxiliary power supply for transmitters. RS-485 ModBus/JBus serial communication. IP 65 and NEMA 4X front protection.
13
1/8 DIN 3 digits temperature controller TMS Configurable outputs (relay or SSR). Load current measurement (in Amps) with output failure alarm. Process, band, deviation or instrument malfunction alarm. Soft start function (timed output power limiting). Output power OFF function. Programmable offset on the measured value. IP 65 and NEMA 4X front protection.
14
Programmers
15
1/4-1/8 DIN Programmers Controllers Set point generators MKP - PKP 200 pattern steps programmable and divisible in up to 90 single + 9 linked programs (sequence of single programs) 5 groups of control parameters applicable to each different pattern of program. Tracking and Guaranteed soak functions to assure the exact correspondence between controlled variable and the program set. 14 digital outputs programmable as control outputs, alarms, timer events or related to the pattern, status (RUN/HOLD) or end of cycle indications.
16
1/4-1/8 DIN Programmers Controllers Set point generators MKP - PKP Clock calendar function for the automatic start, daily or weekly, of a selectable program. Up to 2 independent analog outputs programmable as control outputs or analog retransmission's. Logic inputs for the RUN/HOLD status selection, for the ABORT function activation and for the program selection. RS-485 ModBus/JBus serial communication. IP 65 and NEMA 4X front protection.
17
1/16 DIN mini-programmer controller LFT Five program steps with or without program repetitions. Tracking and Guaranteed soak functions to assure the exact correspondence between controlled variable and the program set. Three independent outputs programmable as control output, event, end-of-cycle indicator or alarm. IP 65 and NEMA 4X front protection.
18
Indicators
19
Digital programmable indicator with linear input DPL Four digits + dummy zero display. Switching power supply from 85 to 264 V AC or 24 V AC/DC. Programmable digital filter on the measured value. 24 V DC auxiliary power supply for 2 and 4 wires transmitters. Analog retransmission of the measured value. RS 485 serial interface. Two independent alarms with auto or manual reset. Maximum and minimum data hold. IP 65 and NEMA 4X front protection 1/8 DIN Digital programmable indicators
20
Digital programmable indicator TIS Programmable TC, RTD and linear input. Switching power supply from 100 to 240 V AC. 24 V DC auxiliary power supply for 2 and 4 wires transmitters. Up to 3 independent alarms with auto or manual reset. Maximum and minimum data hold. Analog retransmission of the linearized measure. IP 65 and NEMA 4X front protection. 1/8 DIN Digital programmable indicators
21
DPS Programmable TC, RTD and linear input. Programmable square root extraction. Ten-segment programmable input linearisation. Maximum and minimum data hold. RS 485 serial interface. Analog retransmission of the linearised measure. Switching power supply from 100 to 240 V AC. Two independent alarms with auto or manual reset. IP 65 and NEMA 4X front protection. 1/8 DIN Digital programmable indicators Panel indicator and transmitter
22
1/16 DIN Safety limiters, indicators and transmitters LHI - LHL - LFS mA Universal input (TC, RTD, linear) IP 65 and NEMA 4X front protection. Rear-of-board version. LHL Limitrol - Safety limiter High limit, low limit or high and low limits with specialized reset functions. LHI - Indicator Two independent alarms with either manual or automatic reset or silence function. LFS mA - Transmitter Isolated retransmission of the measured value. Universal input (TC, RTD, mV, mA, V). Two independent alarms.
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.