1
Engineer Training Control Unit TJ8300 / TJ8500 Control Unit
2
Engineer Training Control Unit TJ8300 / TJ8500 Confidential 2 General Description Located at the bottom of the electronic cabinet Easy front access for all boards inside the Control unit Control bracket
3
Engineer Training Control Unit TJ8300 / TJ8500 Confidential 3 General Description (Cont.) The Control bracket concentrates all controls signals between the electronics cabinet and the computer. The Control bracket is a passive board with DIN connectors for the following boards: I/O Controller Sol/Lamp driver Auxiliary control board (ACB) Galil board It also contains D-type connectors for all proceeding input and output connections.
4
Engineer Training Control Unit TJ8300 / TJ8500 Confidential 4 I/O (Type I) Controller The I/O (type I) controller is placed on the control bracket. Controls most of the printing unit I/O components. Receives input signals from I/O components, placed all over the printing unit, and updates their status to the computer. Provides discrete input and output signals. Has 64 digital inputs and 56 digital outputs.
5
Engineer Training Control Unit TJ8300 / TJ8500 Confidential 5 I/O (Type I) Controller (Cont.) Every active input or output switches on with an indicating LED. Push button for manual reset. RS-232 connector Manual reset Input LEDs (Green) Output LEDs (Orange)
6
Engineer Training Control Unit TJ8300 / TJ8500 Confidential 6 Solenoid Amplifier Driver The Sol/Lamp Driver is dedicated for I/O (type I) controller outputs. It boosts 24 VDC for solenoids and indication lamps switching. It has 32 TTL inputs and a maximum of 32 power outputs. Each output has its own indicating LED and can handle up to 1 Amp 30 VDC. Power outputs of the Sol/Lamp Driver are protected against destructive conditions, such as: short circuit over-current over-voltage
7
Engineer Training Control Unit TJ8300 / TJ8500 Confidential 7 ACB (Auxiliary Control Board) The Auxiliary control board is placed on the Control unit bracket and sends the following signals: Signal for external dryer. Generates the Iron command. 24VDC CCB detection – In the absence of 24VDC for the CCB, the auto drop signal automatically shuts off. Converts the communication from RS232 to RS422.
8
Engineer Training Control Unit TJ8300 / TJ8500 Confidential 8 Components I/O Controller Type 1 Sol/amp Driver Aux Control Board (ACB Board) Control bracket Galil Board
9
Engineer Training Control Unit TJ8300 / TJ8500 Confidential 9 Components (Cont.) I/O Board SOLAMP Board ACB Board Galil Board