1 TrueSTEAM™ Humidification Systems Module 3: Basic Installation

2 Module 3 – Basic Installation Definition of a basic Installation What’s included in the TrueSTEAM™ box Step by step Installation Instructions Cautionary measures for avoiding common installation mistakes What homeowners can expect after a TrueSTEAM™ installation

3 What’s Included in the TrueSTEAM Box?

4 Tools and Parts Needed Tools needed to install TrueSTEAM™ - Wire cutter/stripper - Torx driver T-20 and T-30 - Standard screwdriver - 1-3/4-in. diameter hole saw - 1/8-in. drill bit - 18-gauge wire (up to 5 conductor) Other Optional Parts: - Condensate pump rating of 212°F (100°C) if used. - Drip pan with water sensor shut-off required underneath TrueSTEAM if installed in or above finished space.

5 Tips and Precautions Be sure to read and understand the Installation Guide and complete list of precautions before starting work! - Adhere to voltage, heavy equipment and hot water warnings in the manual - Comply to all install, plumbing, wiring guidelines in the manual, as well as those listed in your local guidelines - Wear safety glasses Do not install in locations which are: - Outside operating temperature range: 34°F to 104°F - In confined space (less than 1 foot of clearance) - Exposed to outside weather DEDICATED TRUESTEAM HOTLINE 800-814-9452

6 Step 1: Choosing a Location Choose a location that has access to a: Vertical surface with adequate clearances. Cold water supply line must be used. Drain with a high-temperature water rating. Electrical circuit rated to your humidifier. HM506 7 Amps HM509 10 Amps HM512 12 Amps Required Minimum Circuit Capacity Model

7 Step 2: Mounting on the Supply Duct Position template on supply duct, and ensure proper clearances from A-coil.

8 Step 3: Mount Bracket Secure bracket to duct using provided self-drilling sheet metal screws.

9 Step 4: Insert Duct Nozzle Install duct nozzle by ensuring o-ring gasket is properly seated in the groove, and slide foam gasket down over nozzle. Insert nozzle and twist clockwise to ensure tight seal of nozzle to TrueSTEAM.

10 Step 5: Mounting TrueSTEAM Push down to secure humidifier to bracket arms. Ensure gasket forms tight seal in duct hole. Allow 4 inches clearance from nozzle outlet to any duct wall and allow 24 inches of downstream open duct air space to prevent duct condensation.

11 Step 6: Plumbing Use only cold water. Do not use hot water supply. a. Water Filter. Insert 1/4-inch copper or plastic water line. Apply modest pull to ensure a tight fit. b. Back-flow preventer valve. Insert 1/4-in. copper or plastic water line. Apply modest pull to ensure a tight fit. c. Connect 1/2-in. drain tube. Secure drain tube to barbed fitting with hose clamp. d. Shut off the water supply. Secure 1/4-in. copper or plastic water feed tube.

12 Step 6: Plumbing

13 After Installation Educate the homeowner on what to expect next. It may take up to a week of continuous operation to achieve the humidity control set point. A slight plastic smell may be detectable the first week of operation. This is normal and will dissipate after running a short time. There may be a slight increase in the homeowner’s energy bill even when TrueSTEAM™ is sized and operating correctly. Set the expectation that comfort costs money to avoid callbacks.

14 Support Materials Additional Materials on TrueSTEAM Installation are available. Visit www.forwardthinking.honeywell.comwww.forwardthinking.honeywell.com - Click on Humidification Enter literature form: #69-2285: TrueSTEAM Installation Manual