8 April 20041 Doors Network Configuration Parameters (Single Site Mode)

Similar presentations


Presentation on theme: "8 April 20041 Doors Network Configuration Parameters (Single Site Mode)"— Presentation transcript:

1 8 April 20041 Doors Network Configuration Parameters (Single Site Mode)

2 8 April 20042 Opening the Setup > System Window Open the Setup > System Window by either: –tool bar button –pull-down menu option

3 8 April 20043 Selecting Network Configuration Click on the Network Config Tab

4 8 April 20044 Network Configuration Two ways to communicate with the access control network: –COM Port communication through a direct serial connection or through a modemCOM Port –TCP/IP communication through a LAN-50, LAN-100, or LAN-500 module to an Ethernet networkTCP/IP Each requires different setup parameters Use one method or the other, not both

5 8 April 20045 COM Port – Selection Select the COM Port the PC will use for either direct connection or a modem connection –Typically COM 1 for newer computers, COM 2 for older computers

6 8 April 20046 COM Port – Modem Phone Numbers Enter the PC modem phone number Enter the access control network modem phone number

7 8 April 20047 COM Port – Modem Init String Enter a Modem Init String only if you have unique conditions that require changes to the default Modem Init String

8 8 April 20048 COM Port – Security PIN For additional security, enter a PIN –The PIN prevents accidental overrides and hacking by preventing other software installations of Doors from accessing the site and the master controller

9 8 April 20049 Network Configuration - Save Changes Click the button –If you close the configuration window without saving, the changes are lost and must be reentered

10 8 April 200410 TCP/IP – Selection Select the TCP/IP option –TCP/IP configuration must be performed with the assistance of a system or network administrator

11 8 April 200411 TCP/IP – Ethernet Port Number Enter the Server’s Ethernet Port Number –The default value is 10021, change this value ONLY if it conflicts with another device on the computer

12 8 April 200412 TCP/IP – Remote Site Address Enter the Remote Site TCP/IP Address –This address must be in industry standard dot notation

13 8 April 200413 TCP/IP – Remote Site Port Number Enter the Remote Site’s Ethernet Port Number –The default value is set to 3001, but may need to be changed to the value specified by the remote site’s Ethernet device LAN-50 and LAN-500 = 10001LAN-100 = 3001 (default) –LAN communication is explained in detail in its own presentation

14 8 April 200414 TCP/IP – Security PIN For optional, additional security, enter a PIN –The PIN prevents accidental overrides and hacking by preventing other software installations of Doors from accessing the site and the master controller

15 8 April 200415 Network Configuration - Save Changes Click the button –If you close the configuration window without saving, the changes are lost and must be reentered