Anthony J Petrella, PhD Statistical Shape Modeling & Probabilistic Methods
2
Practical Challenges in Prob Analysis Quality deterministic model, validated How to estimate input distributions Correlated input variables Complex systems with long solution times require more efficient alternatives to Monte Carlo Implementation Matlab, Excel – simple problems Commercial FE modules (Abaqus, ANSYS, PAM-CRASH) NESSUS – dedicated prob code, integrates with model Validation Anatomical variation?
3
Practical Challenges Quality deterministic model, validated How to estimate input distributions Correlated input variables Complex systems with long solution times require more efficient alternatives to Monte Carlo Implementation Matlab, Excel – simple problems Commercial FE modules (Abaqus, ANSYS, PAM-CRASH) NESSUS – dedicated prob code, integrates with model Validation Anatomical variation? What is the best way to parameterize anatomical shape so that we can easily do Prob simulation to explore effects of anatomical variation?
4
Parameterizing Anatomy Approximate with Primitives Statistical Shape Modeling (SSM) (Laville et al., 2009) Red: + 1* Blue: – 1* Lumbar (Huls et al., 2010) Hip (Barratt et al., 2008) Knee (Fitzpatrick et al., 2007)
5
KS Huls, AJ Petrella, PhD Colorado School of Mines Golden, Colorado USA A Agarwala, MD Panorama Orthopaedics & Spine Center Golden, Colorado USA ICCB 2009, Bertinoro, Italy September 16-18, 2009 Modeling Anatomic Variability for Application in Probabilistic Simulation of Lumbar Spine Biomechanics
6
SSM Background 1 … (N = 8) Training set 2 Morph template mesh → … unique geometry identical topology
7
SSM Background 3 4 Assemble data matrix → Least squares fit → remove variations in translation & rotation retain variations in size and shape (Spoor and Veldpaus, 1980)
8
SSM Background 5 Principal Component Analysis = eigenanalysis on covariance matrix of data, D eigenvectors ( c j ) = fundamental shape modes eigenvalues = variance of a each shape mode across specimens → where the b j coefficients are the “principal components” of specimen P
9
SSM Background 6 New virtual specimens instantiated from SSM → Coefficients b j are assumed normally distributed PDF for each b j randomly sampled to instantiate any number of virtual specimens … bjbj
10
SSM in Orthopaedics & Biomechanics 2D kinematic measures for functional evaluation of cervical spine (McCane et al., 2006) 3D pelvis and femur anatomy for computer-navigated total hip arthroplasty (Barratt et al., 2008) 3D model of hemi-pelvis for use in computer- navigated THA (Meller and Kalender, 2004) Lumbar vertebral bodies (Lorenz and Krahnstöver, 2000) Previous work focused only on individual bones Relative position, alignment, and conformity of articulating surfaces not considered
11
Objectives Develop SSM for lumbar spine, focusing initially on the L3-L4 functional spinal unit (FSU) Determine if virtual specimens instantiated from the SSM are biomechanically viable use finite element (FE) modeling to demonstrate normal facet articulation
12
Methods: Lumbar FSU Lumbar geometry L1-L5 extracted from 8 CT data sets using Mimics software (Materialise, Inc.) 2 Male/6 Female, 54 ± 16 yrs Quadrilateral FE mesh created for L3 and morphed to L4 using HyperMesh software (Altair, Inc.)
13
Methods: Independent SSM for L3 & L4 SSM created for L3 bodies Independent SSM created for L4 bodies L3 and L4 bodies independently instantiated and combined to form L3-L4 functional spinal units We refer to these models as: L3+L4 pairs L3 L4
14
Methods: Unified SSM for L3-L4 For each of the 8 specimens… Least squares fit of L3 to L4 to remove non-physiological alignment created in scanner Unified SSM then created for L3-L4 Virtual specimens instantiated as FSU We refer to these models as: L3-L4 FSU
15
Methods: Leave-one-out Validation Assess ability of SSM to represent the shape of an unknown specimen Randomly selected L3 specimen removed from training data set of 8 CT scans SSM recalculated with only seven specimens Non-linear least squares optimization scheme was used to fit the SSM to the “left-out” specimen
16
Methods: FE Model Virtual specimens created with L3+L4 SSM Specimens also created from SSM of the L3-L4 FSU model ABAQUS (Simulia, Inc.) model constructed for virtual specimens Ligaments: non-linear springs Facet cartilage: linear elastic Annulus: hyper-elastic matrix, linear fibers Nucleus: incompressible fluid cavity L4 fixed, L3 loaded with 10 N·m right axial torque
17
Results: Fundamental Modes of Shape First five PC’s captured 95% of variance in data PC1: scaling PC2: shape and angulation of facet joints PC3: variations in the transverse processes Higher modes were not visually obvious Red: + 1* Blue: – 1*
18
Results: Leave-one-out Validation Maximum Euclidian distance error: 5.6 mm Mean error: 1.9 mm Red: “left out” specimen Blue: SSM fit
19
Results: Lumbar Model Instantiation Appearance of virtual L3+L4 pairs Appearance of virtual FSU specimens FSU-1FSU-2FSU-4FSU-3 L3+L4-1L3+L4-2L3+L4-4L3+L4-3
20
Results: FE Model Facet contact area (p = 0.33) Natural: 158 ± 43 mm 2 FSU specimens: 120 ± 59 mm 2 Average contact pressure (p = 0.55) Natural: 0.79 ± 0.16 MPa FSU specimens: 0.88 ± 0.22 Mpa No FE for L3+L4 specimens due to facet interaction Natural FSU L3+L4
21
Conclusions SSM reasonable for spine, 95% of variance captured by just 5 variables Leave-one-out validation Errors similar to pelvis (Meller and Kalender, 2004) Maybe acceptable for CAOS, but not for biomechanics More specimens needed in training set SSM instantiation L3+L4 facet articulation not viable FSU similar to natural facet interaction Lumbar SSM must include all bodies to ensure reasonable inter-body articulation
22
SSM Summary Why? Continuous parameterization of anatomical shape The basic steps… 1.Collect data for training set 2.Morph to each specimen → identical topology, inter- specimen correspondence 3.Register specimens to common reference 4.Assemble data matrix 5.Eigenanalysis on COV matrix 6.Instantiate new specimens
23
1. Collect data for training set Usually done with medical images CT common for bone geometry MR common for soft tissue, but bone extraction protocols do exist Commercial software typically used Mimics (Materialise) Simpleware Result is usually STL geometry
24
2. Morph template mesh to each specimen Essential for statistical analysis because morph creates Identical topology Inter-specimen correspondence – every vertex / landmark is at the same anatomical location for every specimen Beyond the scope of our discussion, but… Coherent Point Drift: may be used for rigid or non-rigid reg. https://sites.google.com/site/myronenko/research/cpd Non-rigid surface registration: see class website for PDF Other morphing studies: Grassi et al., 2011; Sigal et al., 2008; Viceconti et al., 1998
25
3. Register specimens to common reference SSM quantifies variation in vertex coordinates across all specimens Must remove variation that does not pertain to shape Rigid registration of point sets with different topology Coherent Point Drift – stated previously Iterative Closest Point (ICP) – well known From step 2: we have identical topology Analytical registration method: Spoor & Veldpaus, 1980 based on calculus of variations, see class website for PDF
26
4. Assemble data matrix Arrange each specimen in a column vector with x, y, z coordinates “stacked” as shown Normalize to the mean specimen shape
27
5. Eigenanalysis on COV (C) matrix of D Eigenanalysis equivalent to Principal Component Analysis (PCA) Eigenanalysis of original system is tedious… Rank = max # linearly independent col vectors Rank of C is driven by n (specimens), not by m (data points) Solving the alternate problem is much faster… e.g., 10 4 × 10 4 e.g., 10 × 10
28
5. Eigenanalysis on COV (C) matrix of D
29
6. Instantiate new specimens Assume b i normally distributed New specimens may be created simply with
30
Femur SSM Exercise Exercise is based on a 2D femur meshed with triangular elements See if you can build SSM and instantiate it