Respiratory Protection Personal Protective Clothing EPA Levels of Protection Site Control/Decontamination Larry Wong, CIH University of California Office of the President
2
Personal Protective Equipment (PPE) Head Protection –Hard Hat –5 Year Lifespan Face and Eye Protection –Goggles, Safety Glasses, Face Shield Foot Protection –Safety Shoes, Protective Booties Hand Protection –Gloves Body Protection –Chemical Protective Clothing, Apron
3
Use of PPE Must Meet ANSI Standards Training for PPE User –Proper Use, Storage, Manufacturer’s Instructions –Limitations –Training Prior to Use Clean and Sanitized –Sanitized Between Users If Skin Contact Occurs
4
Chemical Protective Clothing Tyvek® Tychem® QC –Polyethylene Tychem® SL –Saranex®-23P –2.0 Mil Thickness Chemrel™ –Multi-Layer Film Barrier
5
Chemical Protective Clothing Tychem® CPF 1 –1.5 oz/yd 2 Polypropylene Substrate Tychem® CPF 2 –1.5 oz/yd 2 Non-Woven Substrate Tychem® CPF 3 –2.0 oz/yd 2 Polypropylene Substrate Tychem® CPF 4 –2.3 oz/yd 2 Polypropylene Substrate
6
Chemical Protective Clothing Tychem® BR –2.3 oz/yd 2 Polypropylene Substrate Tychem® F –Proprietary Barrier Laminated to Tyvek® 4H ™ or Silvershield ®
7
Haz Mat Protective Clothing Tychem® TK –No Permeation after 8 Hrs. for >260 Chemicals Tychem® Responder® –3.0 oz/yd 2 Polypropylene Substrate Tychem® Responder® CMS –Tychem® Responder® Designed for Weapons of Mass Destruction (WMD)
8
Gloves Butyl Nitrile Neoprene 4H™ or Silvershield® Barrier™ Laminated Film Polyvinyl Chloride (PVC) Polyvinyl Alcohol (PVA) Rubber Viton®
9
Selection of CPC & Gloves Degradation – NR, P, F, G, E Penetration – Seams, Holes, Zippers Permeation - µg/cm 2 /Minute or Hour Breakthrough Time – Minutes or Hours
10
PPE Selection Manufacturer’s Selection Charts Manufacturer’s Fax Number Internet Computer Programs/CD Roms Computer-Aided Management of Emergency Operations (CAMEO®) Program Reference Books
11
PPE Limitations Affects Mobility Hazard Around Machinery Heat Stress –Training in Heat Illness Prevention Program –Work-Rest Cycle –Drink Fluids (8 oz. of Water) Every 30 Minutes –Shaded Work/Rest Area –Biological Monitoring (Heart Rate) –Administrative Controls
12
Donning PPE and Gloves Double Glove Tape Seams
13
Types of Respirators Air Purifying Respirator (APR) –Air Cleaned Through Cartridge and/or Filter Supplied Air –Pressure Demand SCBA
14
Major Respirator Program Elements Initial & Annual Fit-Testing Initial & Annual Training Determination By Physician or Licensed Health Care Professional (PLHCP) Respirator, Cartridges, and/or Filters Must Be Approved By NIOSH (TC Number) Replacement Parts Cleaning, Sanitation, & Storage Program
15
Respirator Protection Factor (PF) PF for a Respirator –Measure of Amount of Protection the Respirator will Provide to Wearer Revised OSHA Respirator Regulation, 29 CFR 1910.134 –Promulgated in 1998 –No Assigned PF in Original 1998 Standard –NIOSH & ANSI Z88.2 PFs were Different
16
Respirator Protection Factor PF in OSHA Regulation: 1910.134(d)(3)(i)(A) –Noticed in Federal Register on August 24, 2006 –Became Effective November 22, 2006 Cal/OSHA Respirator Regulations, Title 8 California Code of Regulations, Section 5144 –Will Adopt New OSHA Assigned Protection Factors in 2007
17
APR Assigned Protection Factors Type of Respirator Quarter Mask Half Mask Full Face- piece Helmet Or Hood Loose- Fitting Facepiece Air-Purifying Respirator (APR) 5 10 50 -------- Powered Air- Purifying Respirator (PAPR) ------- 501000 25* or 1000 25
18
Air-Supplied Respirator Assigned PFs Type of Respirator Half Mask Full Face- Piece Helmet or Hood Loose- Fitting Face- Piece Supplied Air Demand Mode Continuous Flow Pressure Demand 10 50 1000 -------- 25*/1000 -------- ---- 25 ---- SCBA Demand Mode Pressure Demand 10 ---- 50 10,000 50 10,000 ----
19
APRs Filters – Change When Difficult to Breathe Cartridges – Change Schedule or End of Service Life Indicator (ESLI) Annual Fit-Testing –Qualitative or Quantitative Donning –Positive & Negative Pressure Fit-Test
20
Limitations of APR Adequate Oxygen Known Contaminant Known Concentration Concentration <IDLH ESLI or Change Out Schedule
21
Pressure Demand SCBA 30 to 60 Minutes Breathing Air Protection Factor 10,000 Use in Oxygen Deficient Atmosphere Can Be Used in Unknown Contaminant/Concentration Atmospheres Can Be Use in IDLH Atmospheres
22
U.S. EPA Levels of Protection Generally No “Set in Stone” One Type for Each Level (See Attachment A) Main Difference - Type of Respiratory Protection EPA Levels: –Level A –Level B –Level C –Level D
23
Level A Highest Level of Protection Inhalation Hazard and Skin Hazard Fully Encapsulating Suit Supplied Air Respirator
24
Level B Inhalation Hazard –Unknown/IDLH/O 2 Deficiency –Contaminant in Which an Air-Purifying Respirator Cannot Be Used Supplied Air Respirator Protective Clothing May or May Not Be Required
25
Level C Air-Purifying Respirator (APR) Protective Clothing May or May Not Be Required
26
Level D No Respiratory Hazard - No Respirators Protective Clothing May or May Not Be Required
27
Site Control/Decontamination Hot Zone - Contaminated Contamination Reduction Zone – Removal of PPE, Decontamination of Personnel –Located Upwind from Hot Zone Clean Zone – No Contamination
28
Site Control
29
Example of Contamination Reduction Zone Decon Line 1. Contaminated Equipment Drop 2. Remove Tape 3. Remove Outer Gloves 4. Remove Outer Booties 5. Remove SCBA Backpack (Keep Facepiece On) 6. Remove Suit 7. Remove Respirator Facepiece 8. Remove Inner Glove