Download presentation
Presentation is loading. Please wait.
Published byTabitha Gaden Modified over 9 years ago
1
Light and charge collection with a new Micromegas-TPC Light and charge collection with a new Micromegas-TPC Leila Ounalli Neuchâtel University CHIPP workshop on Detector R&D 11-12 June- University of Genova Ionisation Scintillation
2
2 A 2 2/1 1 0 T 0 2 2 0 0 0, m M g g MZEG F V GT Double beta decay and the Standard Model (SM) 122):(,)(,) AZAZee ee - e d(n)u(p) - d(n) u(p) e e W W e d(n)u(p) e - e W d(n) u(p) W e - e If ββ0 exists: Neutrinos are Majorana type
4
The EXO detector
5
Why we need a good energy resolution? Arbitrary units Réaliste Optimiste 2.48 Q ββ [Mev] Realistic Optimistic
6
= 3.3% @ 2.48 MeV EXO: a strong anti-correlation observed between scintillation and ionization signals Combing both Scint & ioniz ) S+I = 1.7 % Ionization only ) I = 4.8 % Scintillation only ) S = 10.3 %
7
Micromegas « Compact » The Micromegas-TPC The Micromegas-TPC 1mm spacers Woven wires http://www.bopp.ch/ (gamma, RX, UV …) e- Cathode Grid Amplification (> 50 m) Micromesh E d ~ 200V/cm E a ~ 40-100kV/cm Anode Conversion + Drift
8
The Neuchâtel mini-TPC prototype miniTPC(10X20cm) The source position. max of count @ d C-g =18cm E drift The drift electric field: E d = 200 V.cm -1.bar -1 The gap dimension (d grid-anode ): (75-100-250 µm) High pressure + low voltages The quencher choice and %: - Xe + (CF 4, isobutene): double beta decay - CF 4 + (Xe, Ar): solar @ low E
9
A higher pressure requires a larger gap 10 4 @ 4 bar 75 µm Gas:P10, E d =200 V.cm -1.atm -1 P={1(black), 2(red), 3(green), 4(blue)} atm 250 µm
10
How to improve the charge collection in Xe? A small CF4 addition is sufficient
11
increases the electron drift velocity in Xe. CF 4 is the best additive for Xe CF 4 addition: reduces longitudinal and transversal diffusions. ← improves the charge collection. P: 1.00 atm, E d =200 V.cm -1.atm -1, Gap: 100 µm ■ Xe-CF 4 (2, 5, 10, 50%) ▲ Xe-isobutene (2%) CF4 is cheap, easy to use, and does not absorb light (t 0 possible)
12
The new Micromegas-TPC for charge & light collection The new Micromegas-TPC for charge & light collection Woven wires http://www.bopp.ch/ Gap 250 μm Cathode Charge read out Light read out Primary ionization (t 0 )
13
Advantages of the new device measure the light emitted by ionization. measure the light emitted by ionization. the anti-correlation Charge-Light. the anti-correlation Charge-Light. Better identification of particles and good determination of the energy deposition localization. Better identification of particles and good determination of the energy deposition localization. A well sealed feedthrough
14
I0I0 I1I1
15
Research & development Continue..
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.