Handheld and Portable Raman Solutions Keegan A. McHose Regional Sales Manager keeganm@bwtek.com www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
2
We Are Your Spectroscopy Partner Global Leader with > 10,000 Portable and Handheld Raman Systems B&W Tek, China Ming Shen Commercial Plaza 400 CaoBao Rd., Suite 2206, Shanghai - 200233, China Phone: +86 021-64515208 B&W Tek, Japan 2-3-2 7F, Kamiochiai, Chuo-ku, Saitama-city, Saitama - 338-0001, Japan Phone: +81(0)48 851 3150 B&W Tek, Corporate Headquarters 19 Shea Way Newark, DE 19713, USA Phone: +1-302-368-7824 Web: www.bwtek.com B&W Tek, Europe Seelandstraße 14-16, 23569 Lübeck, Germany Phone: +49(0)45130803854 www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
3
Raman Spectroscopy www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com 1 photon : 1,000,000 Raleigh Unchanged Elastic Scattering Raman Inelastic Scattering Laser 785 nm Excitation
4
Mid-IRNIR reflectanceRaman Mechanism: absorption by fundamental molecular vibrational modes Molecular Specificity: high Signal Strength: strong Energy: 600-4000 cm -1 Sampling: direct material contact required, glass and water appear opaque; can rarely see through container materials Hardware: probes extremely expensive, and short in length, size and weight Mechanism: absorption by harmonics of fundamental vibrational modes of X-H bonds (e.g., N-H, O-H) Molecular Specificity: low Signal Strength: weak Energy: 4000-12,500 cm -1 Sampling: non-contact, but close proximity to material required (<5 mm) Hardware: longer probes possible (meters); quartz optics; dispersive, interferometry common Mechanism: inelastic scattering by vibrational, rotational, low frequency molecular modes. Molecular Specificity: high Signal Strength: weak Energy: 65-4000 cm -1 shift Sampling: container interference is mitigated by accessories Hardware: CCD detection; quartz optics; long probes common (kilometers in some cases) www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
5
NanoRam Technical Specifications www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com NanoRam BWS455 Detector TE Cooled linear CCD Array Excitation 785nm ± 0.5nm, Stability <0.5cm-1, Linewidth <2.0cm- 1 mW tunable from 0 mW to 300 mW Laser Power Control 0 to 100% in 10% increments Range / Resolution 176cm-1 to 2900cm-1 ~ 9.0 cm-1 @ 785nm Display High Visibility OLED touch screen, 3.7" size Barcode Reader 1D and 2D barcodes Data Formats.txt,.csv,.spc DC Power 12V DC at 6.6 Amps Battery Rechargeable Li-ion Battery, > 5 hours operation PC Software NID Computer Interface USB 2.0, Wifi
6
NanoRam Raman Technology Optimal excitation wavelength of 785nm to reduce fluorescence Complies with USP and EP Ch.2.2.48 guidelines for Raman spectroscopy Accepted cGMP analytical testing method to replace wet chemistry: ICH Q2 R1 www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
7
NanoRam Innovations State of the art laser and cooled sensor technology increases sensitivity Open software design for third party software applications Transfer libraries from instrument to instrument easily www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
8
NanoRam Lean Material Lifecycle Incoming non-destructive testing of Raw Materials Reducing Waste in the Dispensing Suite Plastic Packaging Identification At line identification of intermediates Final product identification Substandard, Adulterants, and Counterfeit Deterrent www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
9
No sample preparation required Scan through: Polyethylene Bags Borosilicate Glass Vials Disposable Pipette Touch Screen allows for quick documentation of sample information NanoRam Ease of Use www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
10
Performance Qualification using polystyrene takes less than one minute Wireless reporting for reduced documentation lead time Remote Administration to reduce unit down time Clear Pass/ Fail results Attachments provide laser safety with built in interlock NanoRam Ease of Use www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
11
NanoRam Good Documentation Practices Fully Traceable results with: Time/ Date Stamps User System Presets Etc. Personalize to your company reporting preference with NID Reported to a secure database that can be linked to your LIMs www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
12
i-Raman ® Plus Technical Specifications www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com i-Raman® Plus BWS465 DetectorBack-Thinned CCD Array Excitation532 nm785 nm830 nm mW< 50mW< 300mW Range / Resolution 532 S: 175 - 4000cm-1 ~ 4.0cm-1 @ 614nm 785 S: 175 - 3200cm-1 ~ 4.5cm-1 @ 912nm 200 - 2300cm-1 ~ 4.0cm-1 @ 912nm Range / Resolution 532 H: 175 - 3300cm-1 ~ 3.0@ 614nm 785 H: 175 - 2700cm-1 ~ 3.5cm-1 @ 912nm Detector Detail-2°C TE Cooled Back-Thinned CCD Array Dynamic Range50,000:1 Power 5VDC at 5.5 amp Optional Battery w/ DC only
13
i-Raman ® Plus Higher S/N ratio allows for greater specificity of materials Greater range allows you to see more C-H Stretching BWIQ allows users to develop Quantitative Raman methods for: Mixture analysis BWID allows user to develop libraries for Final Product Identification Counterfeit Detection Comprehensive suite of accessories, software, allow versatility and portability www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com CH stretching
14
i-Raman ® Ex Technical Specifications www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com i-Raman® EX BWS485 Detector TE Cooled InGaAs Excitation 1064 nm mW <450 mW Laser Power Control 0 to 100% Range / Resolution 175 - 2500cm-1 ~ 4.0cm-1 @ 614nm Dynamic Range 25,000:1 Digitization Resolution 16 bit or 65,535:1 Integration Time 200 μs to >20 minutes DC Power 12V DC at 6.6 Amps Battery Optional
15
i-Raman ® Ex Material Fluorescence reduces applicability on a small subset of materials Utilize 1064 nm excitation Reduce fluorescence Increase productivity Research Grade Enhance material characterization opportunities Extra Virgin Olive Oil with 785nm (in Red) and 1064nm (in Blue) www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
16
i-Raman ® Ex Comparative spectra for an Alka Seltzer tablet www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
17
Services Technical Support IQOQPQ Services Execution Validation Documentation SOP Templates Admin Developer General User Training On-site method development, training and other support services available Customer support 24/7 Phone Line www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
18
Services Regulatory Compliance Supports CFR21 Part 11 Electronic Records and Signature Protocols Supports CFR21 Part 1040.10 Performance Standards for Light Emitting Products Complies with USP and EP Ch.2.2.48 guidelines for Raman spectroscopy ASTM E1840 Raman Shift Standards for spectrometer calibrations www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
19
Services Warranty Programs One year factory warranty comes standard Extended warranty programs of 2 or 3 years can be additionally purchased All warranties can be combined with calibration service www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
20
www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
21
Advantages of Raman Spectroscopy www.bwtek.comwww.bwtek.com | www.nanoram.comwww.nanoram.com
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.