Download presentation
Presentation is loading. Please wait.
Published byLoren Kennington Modified over 9 years ago
1
Comparison of Measured and Modeled Snow Brightness Temperature Using Various Field Techniques for Grain Size Measurement Edward KIM NASA Goddard Space Flight Center Michael DURANDOhio State University Noah MOLOTCHUniversity of Colorado, Boulder Daniel F. BERISFORD Jet Propulsion Laboratory Steven MARGULIS University of California Los Angeles Zoe COURVILLECold Regions Research and Engineering Laboratory
2
Outline Problem statement Our approach Description of snow field measurements EM models Microwave radiometer Tb comparison results Summary & Conclusions
3
The Problem with Snow Remote Sensing and “Grain Size” For microwave remote sensing of snow, accurate grain size numbers are extremely important to have because… the microwave signature of snow is highly sensitive to grain size Unfortunately “grain size” is not easy to quantify accurately, especially in the field So what is the “best” way to measure grain size in the field for use in microwave snow emission models?
4
How to determine a “best” grain size field measurement technique? What do we really need? What do we already have? How do we compare (and will anyone else believe our results)? – What are we going to use as “truth”? What is practical?
5
Our Approach Field Measurements – Small campaign: 6 days, 1 snow pit per day – Limited set of techniques; side-by-side – Stereology chosen as “truth” – Location: Storm Peak Lab, Steamboat, Colorado, USA Brightness Temperature Comparison – Try 2 EM models, both multi-layer – Grain size & stratigraphy info fed into EM models – Models output brightness temperatures (Tb) – Compare model Tb vs. observed Tb
6
Grain Size Measurement Techniques Hand lens NIR photography Spectroscopy – Contact – New probe Stereology
7
Hand lens grain size measurements Plenty of precedent (e.g., CLPX) Non-repeatable (e.g., two pits one meter apart; different days, plus user variations; ‘B’ pit was in the radiometer FOV) P ex & D max related as in Durand, Kim, Margulis, 2008 Pit B Pit A
8
NIR Camera grain size Repeatable (in theory) Empirically-based (transferability?) Matzl and Schneebeli, 2006Mätzler, 2002 Pack Depth ~1m 1m
9
Contact Spectroscopy Measures reflectance across entire VIS/IR range Reflectance varies with grain size (see plot at right) Vertical resolution ~2cm Requires commercial spectrometer ($$) Requires dark tarp to block unwanted background light
10
Spectral Profiler Probe Prototype Sends an optical package into a slotted sleeve inserted into the snowpack to perform contact spectroscopy in-situ, w/o snowpit. Black tarp not shown to block light at base.
11
Spectral Profiler Probe Send optics down hole Lateral reflectance spectra Fiber optic sends signal to spectrometer on surface No snowpit needed! Prototype unit; 1 st field trial, so analysis still in progress probe carrier body drive tube optical camera spectral reflectance probe nylon brush aluminum sleeve fiber optic to spectrometer
12
Stereology grain size (1/4) 3D cast of actual snow grain structure made with dimethyl phthalate Frozen in field with dry ice (stop metamorphism) Shipped to CRREL for processing in cold room Relatively well-known technique, but logistically intensive Perla & Davis, 1980’s & earlier references Matzl and Schneebeli, 2010
13
Stereology grain size (2/4) Time consuming laboratory work to cut and photograph: 20 slices / sample Red line = 1mm
14
Stereology grain size (3/4) Cycloids overlaid on image for estimating surface area Time-consuming manual counting work Yields SSA directly, but then need to convert to p ex for MEMLS Matzl and Schneebeli, 2010 Red line = 1mm L=total length of cycloid lines I=# of intersections crossed v=ice volume fraction D o = optical equiv. grain size
15
Stereology grain size (4/4) Image is classified as air or ice Draw line through image, compute autocorrelation, do for each vertical line Exponential is fit to true autocorrelation function Wiesmann et al., 1998
16
EM models MEMLS Multi-layer HUT
17
MEMLS sensitivity of Tb to grain size Vertically averaged optical equivalent grain size from pit Run MEMLS Sensitivity is the tangent to the curve For this grain size (vertical line), sensitivity is similar for 19 & 37 GHz To achieve 5K Tb accuracy, need 10% grain size accuracy, so for typical grain size, this means
18
Radiometric measurements Brightness measured daily for three days at 19 and 37 GHz, v-pol
19
Results & Discussion Grain size & stratigraphy info fed into EM models Models output brightness temperatures (Tb) Compare model Tb vs. observed Tb
20
MEMLS (p ex ) vs. observations Bias and mean absolute error < 5 K No empirical tuning factors required! Based on laboratory work
21
19v observed: 249 K 19v modeled: 230 K (similar for SPL5 and SPL6) 37v observed: 230 K 37v modeled: 153 K (similar for SPL5 and SPL6) The 19v is off by 20 K, and the 37v is off by 80 K. Averaged together, and you have 50 K. Multi-layer HUT results
22
MEMLS results
23
Multi-layer HUT results Note: HUT is set up to use hand lens Dmax measurements, so we’ve compared that to MEMLS hand lens, and then to MEMLS stereology as a reference
24
Summary & Conclusions Used hand lens, spectroscopy, NIR, & stereology methods to measure grain size; stereology was our ‘truth’ Used the grain size/correlation length to drive EM models (MEMLS, multi-layer HUT) Compared EM model Tb’s vs. observed Tb’s (‘truth’) Using lab-based methods, Tb errors are 5-8 K Using field-based methods, Tb errors are ~10 K For error 20-100um Using p ex directly from stereology, no tuning empirical factor is required Using SSA, an empirical factor (0.74) is required to get the right Tb – attested to in literature (Mätzler, 2002) Need further examination of multi-layer HUT to understand apparent cold bias
Similar presentations
© 2024 SlidePlayer.com. Inc.
All rights reserved.