Weaning from mechanical ventilation in 21 st century Dr P K Dash SCTIMST, Trivandrum
2
Aim of ventilatory care
3
Goals of mechanical ventilation
4
Discontinuing ventilation Easy Quick May not be controversial Initiating ventilation Difficult Time consuming Controversial
5
Do Not Wait Weaning from ventilation vs Discontinuation of ventilation
6
Most accepted method Spontaneous breathing trials – T Piece – Pressure Support – CPAP
7
Pressure Support
8
CPAP
9
T Piece
10
Most commonly used Partial ventilatory support – SIMV – SIMV with PS Less Tried – NIV – BIPAP
11
SIMV with pressure support
12
Evolution of Modes Volume control Pressure control Pressure support Dual control Algorithm based Knowledge based
13
Considerations for Knowledge based weaning
14
Knowledge based weaning 1992 2005 2006 1994
15
What we need
16
Adaptive support ventilation
19
ASV settings
20
ASV monitoring
21
Smart care
22
It is a knowledge based automated weaning system. It contains an automated clinical weaning guideline Based on recognised medical expertise and research.
23
Preconditions patient body weight 35-200 kg ventilator in adult mode CPAP/ASB mode automatic tube compensation deactivated invasive ventilation via ETT or tracheostomy apnoea ventilation on and properly set end tidal CO 2 monitoring through the ventilator flow monitoring activated ΔPASB should be between ΔPASB goal+5 and 35 PEEP 0-20
24
Ventillatory setting
25
Smart Care Zone of Respiratory Comfort – Spontaneous breathing frequency (fspn) 15-30 cycles/min, – up to 34 in patients with neurologic disease – Spontaneous tidal volume (VT) Vt > 300 ml – 250 if weight < 55 Kg, – Endtidal CO2 (etCO2) PetCO2< 55mmHg – 65mmHg if COPD
26
Decision Tree
27
Change in severity of lung illness
28
Smart care working principle Step 1: Stabilizing within a respiratory comfort zone Step 2: Reducing invasiveness Step 3: Testing readiness for extubation
29
Smart care Weaning
30
Contraindications to smart care
31
Neurally adjusted ventilator assist
32
Trigger point Neuro-Ventilatory Coupling Central Nervous System Phrenic Nerve Diaphragm Excitation Diaphragm Contraction Chest Wall and Lung Expansion Airway Pressure, Flow and Volume New Technology Ideal Technology Current Technology Ventilator Unit
33
Conventional triggering Conventional ventilator technology uses a pressure drop or flow reversal to provide assistance to the patient. This is the last step of the signal chain leading to inhalation. This last step is subject to disturbances such as intrinsic PEEP, hyperinflation and leakage.
34
Nava triggering The earliest signal that can be registered with a low degree of invasivity is the excitation of the diaphragm. The excitation of the diaphragm is independent of pneumatic influence and insensitive to the problems with pneumatic triggering technologies. By following diaphragm excitation and adjusting the support level in synchrony with the rise and fall of the electrical discharge, the ventilator and the diaphragm will work with the same signal input. In effect, this allows the ventilator to function as an extra muscle, unloading extra respiratory work induced by the disease process.
35
Components
36
Catheter
37
Signal capture All muscles (including the diaphragm and other respiratory muscles) generate electrical activity to excite muscle contraction. The electrical activity of the diaphragm is captured by an esophageal catheter with an attached electrode array. The signal is filtered in several steps and provide the input for control of the respiratory assist delivered by the ventilator.
38
Catheter verification P and QRS waves are present on the top leads and the P- waves disappear on the lower leads and with a decrease of the QRS-amplitude on the lower leads. When an Edi waveform is present, observe which leads are highlighted in blue. If the leads highlighted in blue are in the center (i.e. second and third leads), secure the Edi Catheter in this position. To finally verify correct positioning of the Edi Catheter press the Exp. Hold and keep the button depressed until a breathing effort is registered. A negative deflection in the pressure curve with a simultaneous positive inflection in the Edi curve verifies correct position of the Edi Catheter.
39
Catheter verification
40
Setting the NAVA level NAVA preview is a help tool to set the NAVA level to reach an estimated NAVA On the uppermost waveform (the pressure curve), there are two curves presented simultaneously. The gray curve shows the estimated pressure, Pest, based on the Edi signal and the set NAVA level. NAVA preview is available in all invasive modes of ventilation except NAVA.
41
Setting the Ventilator
42
Benefits of NAVA
43
Reintubation and Steroids A reintubation rate of 10% is acceptable. Patients deserve a trial of extubation, and many will do well in spite of poor mechanics A high-risk population to develop post-extubation stridor and reintubation can be identified by a cuff-leak test (a low level of leak less than 110 ml or less than 25%). There is convincing evidence for giving steroid therapy at least four hours before extubation to prevent stridor and reintubation in a high-risk population. The steroid benefit remains unclear when patients are not selected.
44