1
Jim Maslowski PDC 2008 Aseptic Filling Single Use Disposable Components Single-Use Fill Lines - The Components & Economies
2
Disposable Single Use Systems Jim Maslowski PDC 2008 Single Use Disposable Components Aseptic Filling The Economies Of The PDC Single-Use Fill Line One Set Of PDC Fill Lines Will Fill Your Entire Batch Set-up Time To Fill Your Batch Is Less Than 1 Hour Turn Around Time Is Minimal CIP SIP Cleaning Is Eliminated Disposal Cost Per Batch Is Minimal – One Set Of PDC Fill Lines Is About 25 Feet Of Tubing, Compared To Manifold Filling That Leaves Thousands Of Feet Of Plastic Tubing For Disposal Lost Product, Left In The Disposable Plastic Tubing Is Minimal
3
Disposable Single Use Systems Jim Maslowski PDC 2008 Single Use Disposable Components Aseptic Filling Single-Use Fill Lines For PDC Aseptic Fillers Dual Fill Line With Integral Disposable Filter At The Product Supply Connection Individual Fill Line With Aseptic Connector At the Product Supply Connection Individual Fill Line With Sanitary Connector At the Product Supply Connection
4
Disposable Single Use Systems Jim Maslowski PDC 2008 Single Use Disposable Components Aseptic Filling Components Of The Disposable Fill Line Aseptic Connector At The Supply Connection Coriolis Flow Meter Liner Tubing Of Customer’s Choice Fill Nozzle With Sterility Cover
5
Disposable Single Use Systems Jim Maslowski PDC 2008 Single Use Disposable Components Aseptic Filling High Flow 1/2” Disposable Nozzle Enlarged View Of Sterility Cover And Nozzle 20 Liter Per Minute Flow Rate ADCF Nozzles Available Internal Screen Inhibits Dripping The Fill Line Is Installed Into The Aseptic Filler. The Nozzle Is Positioned In The Class 100 Fill Zone. The Sterility Cover Is Removed. The Nozzle Remains Sterile. The Internal Molded Screen Helps Eliminate Dripping After The Fill.
6
Disposable Single Use Systems Jim Maslowski PDC 2008 Single Use Disposable Components Aseptic Filling Small Volume 1/4” Disposable Nozzle Enlarged View Of Sterility Cover And Nozzle 3 Liter Per Minute Flow Rate ADCF Nozzles Available Tip Design Inhibits Dripping The Fill Line Is Installed Into The Aseptic Filler. The Nozzle Is Positioned In The Class 100 Fill Zone. The Sterility Cover Is Removed. The Nozzle Remains Sterile. The Tip Design Helps Eliminate Dripping After The Fill. Nozzle Tip Viewed From The End
7
Disposable Single Use Systems Jim Maslowski PDC 2008 Single Use Disposable Components Aseptic Filling Fill Nozzle In The Fill Zone Class 100 Fill Zone With Laminar Flow and Continuous Real Time Particle Monitoring Disposable Nozzle Shown In The Class 100 Fill Area