1
Site Troubleshooting Guide
LTE
2
RBS 6000 Series RBS 6102 RBS 6101 RBS 6201 RBS 6601 RBS 6301 RRU MetroPCS primarily uses RBS 6201 inside a weatherized cabinet MetroPCS primarily uses SIMO Some sites will use RBS 6601 with RRUs, but not currently available
3
Weatherized Cabinet Majority of MetroPCS sites are outdoors
4
Cabinet – Back
5
RBS 6201 Hardware DUL – Digital Unit LTE RU – Radio Unit SIMO Tx/Rx1
6
Cabinet Diagram Fans Radio RUs DUL CC Power SIU C Transmission
7
Cabinet – No Jumpers Power RUs DULs SIU
8
Cabinet – Jumpers Antenna Jumpers Power DUL RUs
9
Diplexer Site Diplexer LTE CDMA Output Input
10
Diplexer Detail Output Input Diplexers
11
Visit Preparation Printed Materials
RFDS Sheet with all plumbing diagrams Notes about site access Directions Satellite image Site Shakedown report Equipment Cabinet key Dummy load set Sitemaster Laptop setup to run TEMS Investigation with UE
12
Equipment Sitemaster Laptop with UE Cabinet Key
13
First Steps Best Practices Take photos! Be prepared
Ensure E-UTRAN support is available Notify relevant parties based on customer procedures Visual Inspection Make sure nothing immediately looks incorrect Trace the RU-DUL cables to ensure there are no swaps Ensure the RU-DUL cables have a good connection Check small QMA wave guide for damage and ensure connection
14
Photos Take a photo of the site label to identify pictures
15
RU to DUL Jumper check Ensure the RU-DUL jumpers are correct DUL RU
16
RUL QMA Wave Guide Check
Check small QMA wave guide for damage and ensure connection Bent Correct
17
RUL QMA Wave Guide Check
Bent Connector Disconnected Connector
18
Common Issues Sector Swaps DL or UL throughput low Bad or no coverage
Azimuth incorrect
19
Sector Swaps Causes RU-DUL cables Jumpers from cabinet to diplexer
Jumpers from diplexer to antenna feeders Antenna feeders to antennas CDMA incorrect Do not trust colors on cables Troubleshooting Steps E-UTRAN lock test Cable tracing
20
E-UTRAN Lock Test Procedure Conclusion
Have E-UTRAN lock a single sector Verify the reference signal transmit light stops blinking Repeat for each sector Conclusion Ensures that the DUL is configured correctly Verifies there is no RU-DUL cable swap
21
E-UTRAN Lock Test Blinking No Light Transmitting reference signals
Locked
22
Antenna Jumper check Verify all cables match colors in plumbing diagrams Non-diplex site Trace the antenna jumpers from the RUL to the back of the cabinet Trace the antenna jumpers from the cabinet to the antenna feeders Diplex site Trace the antenna jumpers from the cabinet to the diplexer Trace the antenna jumpers from the diplexer to the antenna feeders
23
Antenna Jumper Check Verify all cables match colors in plumbing diagrams Sector 4 Sector 5 Sector 6
24
Antenna Jumper Check Trace the antenna jumpers from the RUL to the back of the cabinet Jumpers exit cabinet Jumpers at RUL
25
View – Cabinet Back Jumpers exit cabinet
26
Antenna Jumper Check Trace the antenna jumpers from the cabinet to the antenna feeders Jumpers from cabinet Antenna feeders
27
Antenna Jumper Check – Diplex
Trace the antenna jumpers from the cabinet to the diplexer Jumpers from cabinet Jumpers enter Diplexer
28
Antenna Jumper Check – Diplex
Trace the antenna jumpers from the cabinet to the diplexer Jumpers from cabinet Jumpers enter Diplexer
29
DL or UL throughput low Causes Troubleshooting Steps Backhaul
Antenna system and jumpers Hardware problems with RU-DUL Troubleshooting Steps Dummy Load Test Feeder Sweeps E-UTRAN support
30
Dummy Load test Procedure
Trace the power connector to the RUL and turn it off Detach the antenna jumpers from the RUL Connect the attenuators to the RUL Connect the dummy antennas to the attenuators Power on the RUL Have EUTRAN unlock the target sector and lock all other sectors Place the UE near the dummy antennas Upload and download a file and record a TEMS log Conclusion Eliminates or identifies antenna system cause of problem
31
Dummy Load Test Trace the power connector to the RUL and turn it off
Power light off
32
Dummy Load Test Detach the antenna jumpers from the RUL
Disconnected Jumpers
33
Dummy Load Test Connect the attenuators to the RUL
Use high power attenuators Adapters Attenuators Ensure attenuators are connected to both Tx/Rx2 and Rx2
34
Dummy Load Test Connect the dummy antennas to the attenuators
35
Dummy Load test Power on the RUL Power light on Power Button
Power Connector
36
Dummy Load Test Have EUTRAN unlock the target sector and lock all other sectors Ensure blinking
37
Dummy Load Test Place the UE near the dummy antennas Dummy antennas UE
38
Dummy Load Test Upload and download a file and record a TEMS log
39
Feeder Sweeps Tests Voltage Standing Wave Ratio Return Loss
Distance to Fault Covered in a different guide Conclusion Determines if there are problems in the antenna system
40
E-UTRAN support Procedure Conclusion
Connect to the cell (dummy load or otherwise) Download or upload a file Have E-UTRAN monitor the node Conclusion Determines if there is a configuration problem or a problem in the backhaul
41
Bad or No Coverage Causes Troubleshooting Steps Antenna System
Jumpers not connected Hardware problems with RU-DUL (damaged connectors) Troubleshooting Steps Ensure all connectors are tightly secured Dummy Load Test Feeder Sweeps
42
Incorrect Azimuth Troubleshooting Steps Drive Test
Visual inspection of antenna direction
43
THANK YOU