Presentation is loading. Please wait.

Presentation is loading. Please wait.

Pt5 - RadWG meeting Presenting a concept Prepared by M Gastal & S Maridor

Similar presentations


Presentation on theme: "Pt5 - RadWG meeting Presenting a concept Prepared by M Gastal & S Maridor"— Presentation transcript:

1 R2E @ Pt5 - RadWG meeting Presenting a concept Prepared by M Gastal & S Maridor 25/03/20101martin.gastal@cern.ch

2 CERN, February 9 th Extended R2E Seminar & Workshop Preparation CERN, February 9 th Extended R2E Seminar & Workshop Preparation F. DELSAUX ENVIRON 18 M HT LIBRE 2600 mm CHICANE UJ56 1500 R562 VERS UJ56 VERS UJ57 UJ56 Shielding Option 2

3 CERN, February 9 th Extended R2E Seminar & Workshop Preparation CERN, February 9 th Extended R2E Seminar & Workshop Preparation BLINDAGE UJ56 MUR FIXE ACIER HAUTEUR 2000mm COMPLEMENT BRIQUETTES ACIER HAUTEUR 600mm BLINDAGE ACIER DEMONTABLE EP. 400mm HAUTEUR 2000mm MONORAIL RAIL DE MANUTENTION DES BLOCS DE BLINDAGE 300mm 800mm 300mm 400mm xz view UJ56 Shielding Option F. DELSAUX 3

4 25/03/2010martin.gastal@cern.ch4 UJ56 1 st floor Compensators 24 racks

5 25/03/2010martin.gastal@cern.ch5 UJ56 Gnd Floor

6 Issues in the UJ56 Shielding effectiveness GND Floor ~10 Shielding effectiveness 1 st Floor ~2 25/03/20106martin.gastal@cern.ch

7 Issues in the UJ56 Shielding effectiveness GND Floor ~10 Shielding effectiveness 1 st Floor ~2 25/03/20107martin.gastal@cern.ch

8 Goal and initial idea Goal: Find a permanent solution to relocate the electronics in the UJ56 Limitation: For some equipment the cable length is critical (compensators) Idea: Find some room in the USC55 if not detrimental to CMS 25/03/20108martin.gastal@cern.ch

9 Very first draft proposal Move all or part of the EL safe room on the ground floor of the UJ56 into the USC55 Lower the power converters from the 1 st floor of the UJ56 to the ground floor and build adequate shielding Move all remaining racks from the 1 st floor of the UJ56 into the USC55 (Cryogenics, WIC, Timing, Remote-Reset, UPS, Access Control, Network, AUG control, Electrical Distribution (Control), GSM, Fire/ODH) 25/03/20109martin.gastal@cern.ch

10 39racks 25/03/201010martin.gastal@cern.ch

11 UJ56 Gnd Floor Area taken by power convertors → integration to be studied 11martin.gastal@cern.ch Shilding 25/03/2010

12 12martin.gastal@cern.ch

13 5 transformers could be brought up and housed in a surface building together with other CMS electrical equipment (eg 3 MVA UPS) All or part of the UJ56 safe room could be relocated in the freed area 25/03/201013martin.gastal@cern.ch

14 Service Area L-2 5 x 2MVA transformer to be Relocated on the surface USC55 14martin.gastal@cern.ch25/03/2010

15 Footprint of the UJ56 safe room → Intergration to be studied Service area L-2 USC55 15martin.gastal@cern.ch25/03/2010

16 16martin.gastal@cern.ch Footprint of the UJ56 safe room → Intergration to be studied Service area L-2 USC55 25/03/2010

17 USC55 17martin.gastal@cern.ch Footprint of the UJ56 safe room → Intergration to be studied Service area L-2 25/03/2010

18 2 candidate areas to relocate the 24 racks from UJ56 – Preferred option: Top of CV room – Back up: part of underground control room 25/03/201018martin.gastal@cern.ch

19 Top Of CV room Area available for UJ56 racks USC55 19martin.gastal@cern.ch25/03/2010

20 Underground Ctrl room USC55 20martin.gastal@cern.ch 24 racks (uj56 du 1 er ) → Integration to be studied 25/03/2010

21 Relocate UJ56 racks in USC55 control area Existing floor beams already suitable If need be, build a second floor to house a control room 25/03/201021martin.gastal@cern.ch


Download ppt "Pt5 - RadWG meeting Presenting a concept Prepared by M Gastal & S Maridor"

Similar presentations


Ads by Google