Power Systems
2
Lesson Objectives When you finish this lesson you will understand: Control of the high electrical power systems, transformer control Timing functions Calculation of the heat Troubleshooting Learning Activities 1.View Slides; 2.Read Notes, 3.Listen to lecture 4.Do on-line workbook 5.Do Homework Keywords Power Systems, Single Phase AC, Single Phase Rectified, Three Phase, Three Phase Rectified, Frequency Changer, Inverter, Transformer, Tap Switches, Saturation, Hysteresis, Reactance, Inductance, Resistance, Impedance, Power Factor, Duty Cycle, Timing Controls, Synchronous, Phase Shift Heat Control, SCR, half wave rectified, Full Wave Rectified
3
Machines and Equipment Cooling System Mechanical System –Force generation system Pneumatic/Hydraulic system Motor or foot-operated system –Electrode application system Rocker arm or pinch type Press or direct action type Portable system Electrical System –Single-phase system –Single-phase rectified system –Three-phase rectified system –Frequency changer system –Frequency inverter system
4
Block Diagram of Single-Phase Spot Welder Spot Weld Main Power Line Contactor
5
Configurations for Spot Welding Transformers (a) Stacked, Shell Type (b) Stacked, Core Type(c) Wound Type
6
W. Stanley, Resistance Welding McGraw-Hill, 1950
8
Parallel/Series Tap Switches EsEs EsEs EsEs EsEs VpVp S1S1 S1S1 S2S2 S2S2 P2P2 P2P2 P1P1 P1P1 VpVp (a) Parallel (b) Series
9
Transformer Tap Switch EsEs VpVp
10
Applied Magnetic Field Induced Magnetic Filed Saturation Induction Remnant Induction Coersive Force Structure & Properties of Materials, Wiley, 1967
11
RpRp XpXp RsRs XsXs X = reactance in Ohm L = inductance in Henry f = frequency in Hertz Z = impedance in Ohm R = resistance in Ohm
12
Power Factor DC Current AC Current Ohm’s Law I= Current V= Voltage R= Resistance Z= Impedance X= Reactance Frequency of AC Geometry of Secondary Magnetic Material Power = VI =KW (kilowatts) Power = KVA
13
Power Factor P V P I I V (a) Purely Resistive Load (b) Resistive and Reactive Load P av = V av I av cos( )
14
Power Factor = Cos If: I=10,000 amps V=10 volts Kva=100 Kw=70.7 If: R=X pf = 70.7%
15
Variables Affecting Power Factor Machine Design Single-Phase versus Three-Phase Current Frequency Reactance/Resistance of the Secondary Loop Magnetic Material in the Throat
16
Resistance Welding Manual, RWMA, 1972 R X Increased Angle Decreased Power Factor Increased Throat Length
17
Ferrous Material in Throat Resistance Welding Manual, RWMA, 1972 R X Reduced Power Factor
18
Power Factor Correction Capacitors Contactors (Switched Simultaneously) High Impedance DC Charging Circuit AC Power Supply AC Power Supply Welding Contactor Normally-Closed Contactor Discharging Resistor Tuned Capacitor (a) Shunt Capacitors (b) Series Capacitors
19
Duty Cycle is the power level at which a transformer can operate for some fraction of time without overheating Percent Duty Cycle Percent Rated Load 50% 100%
20
Timing Controls Non-synchronous Controls Synchronous Controls Microprocessor Control = Synchronous At what point in time do we close the contactor
21
Electronic Control Res. Weld, McGraw-Hill, 1943 Synchronous Timing Accuracy
22
Transient Currents with Non-Synchronous Timing Electronic Control Res. Weld, McGraw-Hill, 1943
23
Electronic Control Res. Weld, McGraw-Hill, 1943
24
Control of Secondary Current Transformer Tap Setting (Turns Ratio) Phase Shift Heat Control
25
Rules for SCR Conduction can conduct when anode is + with respect to cathode once initiated, can only be stopped by removal of anode voltage initiated by a pulse on ignitor Cathode Anode Gate
26
Welding Handbook
27
“Idealized” Phase Shift Heat Control (a) Current Controlled by Tape Settings (b) Current Controlled by Phase Shift Setting In Actual Case, Current can not instantaneously change
28
Firing Angle Hangover Angle Related to R/L ratio Actual Condition Androvich “Resistance Welding Constant Current Heat Control”, AWS Sheet Metal ConfV, 1992
29
I RN = Normalized Available RMS Current Androvich “Resistance Welding Constant Current Heat Control”, AWS Sheet Metal ConfV, 1992
30
Tsai, Experimental Study of Weld Nugget Expan, Paper B1, Sheet Metal Welding Conf V, AWS, 1992
32
Link to: Phase Shift Heat Control Demo
33
Portable Trans Guns Transformer Integral with Gun Thus smaller in Size Nedorezov, J “Using Portable Transguns for Resistance Spot Welding”, Practical Welding Today, Nov-Dec 1997
35
Machines and Equipment Cooling System Mechanical System –Force generation system Pneumatic/Hydraulic system Motor or foot-operated system –Electrode application system Rocker arm or pinch type Press or direct action type Portable system Electrical System –Single-phase system –Single-phase rectified system –Three-phase rectified system –Frequency changer system –Frequency inverter system
36
Single-Phase Rectified System Center-Tapped Transformer Bridge-Type Rectifier Primary Current Secondary Current
37
Single-Phase Rectified System Advantages Higher Power Factor More Uniform Heat Flow Pattern Less pf Loss by Material in Throat Disadvantages Expensive Need Heavy Duty Diodes One Electrode Wears Rapidly Load on one side of Three Phase Line Balanced 3 phase hook-up needed A B C
38
Machines and Equipment Cooling System Mechanical System –Force generation system Pneumatic/Hydraulic system Motor or foot-operated system –Electrode application system Rocker arm or pinch type Press or direct action type Portable system Electrical System –Single-phase system –Single-phase rectified system –Three-phase rectified system –Frequency changer system –Frequency inverter system
39
Three-Phase Rectified System Half Wave Full Wave Primary Current Secondary Current 10% Heat 100% Heat
40
120° Half Wave Full Wave * * **
41
Spinella, D., “Al RSW: Capital and Operating Costs”, AWS Xsheet Metal Conf, 1996
42
Comparison of Two PF on Three Machines High Ripple Medium RippleLow Ripple Roth, “Alternating Current Vs DC in Resistance Welding” AWS Sheet Metal Conf IV, 1990
43
Both Single Phase and 3 Phase DC is best in low power factor (high inductive) circuits providing as much smoothing as possible Phase shifting will increase ripple (more in single phase). Operate on the highest phase shift and lowest tap setting possible Comparison of Two PF on Three Machines
44
Roth, “Alternating Current Vs DC in Resistance Welding” AWS Sheet Metal Conf IV, 1990 Need to get comparison with 3 phase DC circuit 2 as 100%
45
Advantages High Power Factor Uniform Heat Flow No need to balance hook-up No pf loss by material in throat Disadvantages Expensive Need Heavy Duty Diodes One Electrode Wears
46
Machines and Equipment Cooling System Mechanical System –Force generation system Pneumatic/Hydraulic system Motor or foot-operated system –Electrode application system Rocker arm or pinch type Press or direct action type Portable system Electrical System –Single-phase system –Single-phase rectified system –Three-phase rectified system –Frequency changer system –Frequency inverter system
47
Controller A Controller B Controller C 1 2 3 Frequency Converter
48
Frequency Changer System (a) Frequency-Changer (b) Rectified
49
Advantages Power Factor > 98% Balanced Loading Balanced Electrode Wear Disadvantages Cost Control Problems
50
Machines and Equipment Cooling System Mechanical System –Force generation system Pneumatic/Hydraulic system Motor or foot-operated system –Electrode application system Rocker arm or pinch type Press or direct action type Portable system Electrical System –Single-phase system –Single-phase rectified system –Three-phase rectified system –Frequency changer system –Frequency inverter system
51
Frequency Inverter System DC Rectifier AC 60 Hz Oscillator AC HF 400, 600, or 1200 Hz
52
Advantages Disadvantages High Power Factor > 98% Less Core Material Lighter & Smaller – suitable for robots Cost Newer Process – Still Under Development
53
Duty Cycle