Download presentation
Presentation is loading. Please wait.
Published byLeah Hakes Modified over 9 years ago
1
ABTECH Scientific, Inc. Virginia Biotechnology Research Park 800 East Leigh Street, Suite 52 Richmond, Virginia 23219 USA sales@abtechsci.comhttp://www.abtechsci.com Microlithographically Fabricated Chips and Microelectrodes for Chemical and Biological Sensor Research and Development
2
Microfabricated Interdigitated Microsensor Electrodes (IMEs) IME XX50.5 M, CD, FD; Au, Pt, ITO XX = 5, 10, 15, 20 m
3
Microelectrodes Oxygen Microelectrodes pH and REF Microelectrodes
4
IME 1010.3 FD Au, Pt, ITO Liquid Flow Cell Detector
5
IME 1010.3 FD Au, Pt, ITO Gas / Vapor Flow Cell Detector
6
MDEA XXX Au, Pt Microdisc Electrode Arrays 1
7
MDEA DEVICES Disc dimensions / Number of Discs Active Area Conductor MDEA 3600 D = 3,600 m 1 disc 0.10 cm 2 Au, Pt, ITO MDEA 250 D = 250 m 207 microdiscs 0.10 cm 2 Au, Pt, ITO MDEA 100 D = 100 m 1,296 microdiscs 0.10 cm 2 Au, Pt, ITO MDEA 50 D = 50 m 5,184 microdiscs 0.10 cm 2 Au, Pt, ITO 50 m100 m250 m x 50 3600 m x 50 Microdisc Electrode Arrays 2
8
50 m 100 m 250 m 3600 m Microdisc Electrode Arrays 3
9
PAnCl on MDEA 50 Au x50 PAnCl on MDEA 100 Au x50 PAnPSS on MDEA 100 Au x50 PAnPSS on MDEA 50 Au x50 Total current density applied = 100 mA/cm 2 Total time = 20 s Total charge density = 2 C/cm 2 Microdisc Electrode Arrays 4
10
Independently Addressable Microband Electrodes (IAMEs) XX = 5, 10, 15, 20 m Microband Electrodes IAME XX04, Au, Pt or ITO
11
Independently Addressable Interdigitated Microsensor Electrodes (IAIMEs) XX = 5, 10, 15, 20 m Microband Electrodes IAIME XX10, Au, Pt or ITO
12
A B C D E F G Electrochemical Cell-on-a-Chip (ECC)
13
XX = 05, 10, 15, 20 m ECC IME XX04, Au, Pt or ITO 2 cm 1 cm C1 C2 A B C D E F G
14
Counter Electrode Interdigitated WE1 and WE2 Reference Electrode, Ag/AgCl Si 3 N 4 Passivation Layer Unmodified Polypyrrole modified Unsilverized Silverized Electrochemical Cell-on-a-Chip (ECC)
15
An integrated biochip showing the microfabricated pattern of electrodes bonded and sealed into the Microncs’ microfluidic T-cassette. Electrochemical Cell-on-a-Chip (ECC) Integrated in a Microfluidic Cassette Polypyrrole modified
16
IAME-co-IME 2-1 Au, Pt Independently Addressable Microband Electrodes and Microfrabricated Interdigitated Microsensor Electrodes)
17
4 bands 3 mm long 2 m lines, 1 m space 5 + 5 fingers 3 mm long 2 m lines, 1 m space IAME-co-IME 2-1 Au, Pt Independently Addressable Microband Electrodes and Microfrabricated Interdigitated Microsensor Electrodes)
18
IAME-co-IME 2-1 Au, Pt
19
Independently Addressable Microband Electrodes and Microfrabricated Interdigitated Microsensor Electrodes) 2 line 1 space
20
Chips of 5μm, 10μm, 15μm and 20μm with electropolymerized PPyCSA Sensor Arrays of VOC Responsive Polymers for the Electronic NOSE
21
People Scientific Advisory Board Anthony Guiseppi-Elie, Sc.D. David Allara, Ph.D. (Penn State University) Norman Sheppard, Jr. Management Team James W. Sharpe, MBA Chairman and CEO Anthony Guiseppi-Elie, Sc.D. President and Scientific Director James R. Funkey, MA, CPA VP and Controller Ann M. Wilson Director, Applications Development TBH VP, Business Development Board of Directors James W. Sharpe, MBA Chairman Anthony Guiseppi-Elie, Sc.D. President and Scientific Director Annette Guiseppi-Elie, Ph.D. Cynthia Garwon-Burke, Ph.D. Patent and IP Council Leigh P. Gregory Patent Attorney Clemson, SC, USA
Similar presentations
© 2025 SlidePlayer.com. Inc.