Qualified Partner Program Installation Cables Felice Guarna, Training Program Manager Wetzikon, Dec. 2005
2
Installation Cables / Page 2 Dec. 2005 " R&Mfreenet " copper cables Comprehensive range of twisted pair cables to set up the R&Mfreenet system Screened and unscreened cables Different jacket materials to meet safety standards Bandwidths up to 1.2 GHz All cables are 3P tested and listed All cables comply with the current standards All cable values are measured after Installation Simulation
3
Installation Cables / Page 3 Dec. 2005 Assortment of multi-pair cables voice backbones applications Cable typeCable materialAvailable lengths Cat 3 U/UTP multi-pairLS0H300 m reel Cat 5e U/UTP multi-pairLS0H300 m reel Cat 3 F/UTP multi-pairLS0H300 m reel Cat 5e F/UTP multi-pairLS0H300 m reel
4
Installation Cables / Page 4 Dec. 2005 Assortment of 4 pair cables data applications Cable typeCable materialAvailable lengths Cat. 5e U/UTP PVC and LS0H 500 m reel, 305 m box Cat. 6 U/UTP PVC and LS0H 500 m reel Cat. 6 U/FTPLSFR0H 500 m reel Cat. 5e F/UTP PVC and LS0H 500 m reel, 305 m box Cat. 5e SF/UTPPVC and LSFR0H 500 m reel Cat. 6 S/FTPLS0H 500 m reel Cat. 7 S/FTP LSFR0H 500 m reel Multimedia S/FTPLSFR0H500 m reel
5
Installation Cables / Page 5 Dec. 2005 Cat. 5e, 6, 7 and Multimedia cables Features All cables comply with the ISO/IEC 11801, EN 50173, EN 50167, EN 50169, EIA/TIA 568A, prEN 50288-x-x specifications Fulfill the stricter Cat. 5e requirements Fulfill the latest Cat. 6 and 7 requirement Fulfill the Industry proposed Standards where Official Standards are not available All cables are 3P tested and certified 100 ohm versions IEC color code Operational temperature range: -20°C to +75°C
6
Installation Cables / Page 6 Dec. 2005 Fire, smoke density and gas tests requirements IEC 60332-1: Test on one single cable IEC 60332-3 Cat. C: Test on one bundle of cables IEC 61034: Measuring the smoke density under the defined conditions IEC 60754: Measuring the halogen gases during the combustion of plastic
7
Installation Cables / Page 7 Dec. 2005 IEC 60332-1 fire test fire propagation A gas burner is held against the cable for 1 minute continuously. After 1 minute the gas burner is switched off. The cable must extinguish on its own. The burnt zone must not exceed 425 mm. Simple test PVC and LS0H pass this test
8
Installation Cables / Page 8 Dec. 2005 IEC 60332-3c fire test on bundles of cables fire propagation Complete fire test. Carried out in a special fire chamber. Approx. 100 pieces of cables required. Fire duration 20 min. The flames must only spread on a height of 2.5m. FR (Fire Retardant) cables have special additives. Only LSFR0H pass this test.
9
Installation Cables / Page 9 Dec. 2005 IEC 61034 smoke density test Measuring the smoke density to assure escaping routes visibility during fire PVC produces thick, black smoke (visibility ~ 10%). Test fails Smoke doesn’t allow visibility of safety exits Problematical in the cabling in air shafts. LS (Low Smoke) cables produce less smoke (visibility ~ 90%). Test passes Safety signs are visible. People can be localized and rescued.
10
Installation Cables / Page 10 Dec. 2005 IEC 60754 measuring halogen content of gases Measuring the quantity of halogen content produced during the combustion of materials of the cables Halogen gases corrosiveness has double negative effects on: Human – intoxicate people causing death before fire Equipment – water used during fire extinguishing will contain chlorine which is highly corrosive for electronics PVC contains elements which release halogen gas during combustion or carbonization 0H (Zero Halogen) cables produce no halogen gases.
11
Installation Cables / Page 11 Dec. 2005 Features Multi-pair cables for telephonic applications. Suitable for voice, video (and data) transmission at frequencies of up to 16 MHz. Dimension: pair x2x0.5 mm (AWG24). Versions: 25, 50 or 100 pairs. U/UTP or F/UTP versions. LS0H cable jacket (IEC 332-1) Multi pair riser cables: Cat. 3
12
Installation Cables / Page 12 Dec. 2005 Features Multi-pair cables for telephonic applications. Suitable for voice, video (and data) transmission at frequencies of up to 100 MHz. Dimension: pair x2x0.5 mm (AWG24). Versions: 25, 50 or 100 pairs. U/UTP or F/UTP versions. LS0H cable jacket (IEC 332-1) Multi pair riser cables: Cat. 5e
13
Installation Cables / Page 13 Dec. 2005 Features Unscreened 100 Ω installation cables. 4 pairs or Siamese (2x4pairs) 0.5 mm conductor diameter. Electrical values far better than cabling Standards Plastic foil as protection; no cutting into the conductor insulation. PVC or LS0H cable jackets. 5.5 mm overall diameter (4 pair version). Installation cables, Cat. 5e, U/UTP
14
Installation Cables / Page 14 Dec. 2005 Features Unscreened 100 Ω installation cables 4 pairs only (no Siamese version). 0.57 mm conductor diameter. 7.1 mm max overall diameter. Inner spacer to improve NEXT values. Electrical values far better than cabling standard requirement even above 250 MHz PVC and LS0H cable jackets. Installation cables, Cat. 6, U/UTP
15
Installation Cables / Page 15 Dec. 2005 Installation cables, Cat. 6a, U/UTP 10G solution Features Patented WARP technology Unscreened 100 Ω cable (no Siamese version). .56mm conductor diameter 8.6mm overall diameter Inner spacer to improve NEXT value Aluminum interrupted foil to equalize ANEXT without increasing excessively the diameter Electrical values far better than cabling standard requirement even above 650 MHz LS0H cable jackets.
16
Installation Cables / Page 16 Dec. 2005 Features 4 pairs individually foiled 100 Ω Siamese version available 0.55 mm conductor diameter. 7 mm max (4 pairs version) overall diameter Greatly improved NEXT values. Electrical values far better than cabling standard requirement even above 250 MHz LS0H cable jackets. Installation cables, Cat. 6, U/FTP
17
Installation Cables / Page 17 Dec. 2005 Installation cables, Cat. 5e, F/UTP Features Aluminum foil-screened, 100 Ω cables. 4 pairs or Siamese (2x4 pairs) version. 0.5 mm conductor diameter. 6.1 mm overall diameter. Drain wire (0.5 mm) present Mylar tape present PVC and LS0H cable jackets.
18
Installation Cables / Page 18 Dec. 2005 Installation cables, Cat. 5e, SF-UTP Features Braided/foil-screened, 100 Ω installation cable: alu-foil and tin-plated copper braid for high and low frequency interference fields. 4 pairs or Siamese (2x4 pairs). 0.5 mm conductor diameter. 6.5 mm overall diameter. PVC, LS0H and LSFR0H cable jackets.
19
Installation Cables / Page 19 Dec. 2005 Features 4 Pair-screened 100 Ω installation cable. 4 pairs or Siamese version 0.55 mm conductor diameter. 7.4 mm overall diameter 41% surface covered by braid. Cable trimmed to a small overall diameter (7.4 mm) and best performance (Cat. 7). LS0H cable jacket. Excellent NEXT AND ANEXT > 30dB ACR at 600 MHz. Installation cable Cat. 6e (600MHz), S/FTP
20
Installation Cables / Page 20 Dec. 2005 Installation cables Cat. 7, S-FTP Features 4 Pair-screened 100 Ω installation cable. 4 pairs or Siamese version 0.58 mm conductor diameter. 7.9 mm overall diameter 65% surface covered by braid. LSFR0H cable jacket. Excellent NEXT AND ANEXT > 35dB ACR at 600 MHz.
21
Installation Cables / Page 21 Dec. 2005 Features Individually shielded pairs with overall, shielding braid. Flame retardant/zero halogen according to IEC 332-3c. 4 pairs or 2x4 pairs. 0.64 mm conductor diameter. 8.2 mm overall diameter 65% optical braid coverage. Excellent NEXT AND ANEXT > 17dB ACR at 1.2GHz. Installation cables Cat. 7 (1200 MHz), S-FTP