Thought Technology Ltd. Rehabilitation Suite Welcome Introductions Handouts Rehabilitation Suite Welcome Introductions Handouts Online Course - Lesson 1
2
Thought Technology Ltd. Aileen in Singapore Using for Continence Learning about the equipment SDNN, and more.. Aileen in Singapore Using for Continence Learning about the equipment SDNN, and more.. Course Participants
3
Thought Technology Ltd. Lesson 1 Outline Today’s Lesson 1. BioGraph Infiniti Software 2. Sensors 3. Setting up the software 4. Replaying a session 5. Q&A and Homework
4
Thought Technology Ltd. Participants will be able to: Course Objectives Locate HRV training screens and understand general software functions Identify and understand the basic signal processing steps involved in calculating the time/frequency domain HRV metrics Identify and understand the physiological signals used for HRV training (EKG, BVP and respiration) Learn to optimize electrode and sensor placement for signal quality Understand the physiology of respiration sinus arrhythmia (RSA) training Run training sessions using time-domain HRV metrics (HR Max-Min, SDRR & pNN50)
5
Thought Technology Ltd. BioGraph Infiniti To open the main program, double click on the white BioGraph Infiniti icon on the desktop
6
BIOFEEDBACK FOUNDATION OF EUROPE The Foundation for Learning Typical Encoders Sampling rates –ProComp Infiniti 8 inputs A-B: 2048 Hz C-H: 256 Hz –ProComp 2 2 inputs (built in EEG in A) A-B: 256 Hz C-D: 32 Hz
7
Manuals Physiology User Suite Manual Quick Start PDF Docs BioGraph Infiniti
8
Thought Technology Ltd. Questions? Lesson 1
9
Thought Technology Ltd. EKG Sensor Placement
10
Thought Technology Ltd. EKG Sensors
11
Thought Technology Ltd. Lesson 1
12
Thought Technology Ltd. Respiration - Sensors
13
Thought Technology Ltd. Respiration Things to watch for 1. Belt placement 2. Chest & Belly breathing 3. Use two belts if you can 4. If you can’t start with belly breathing
14
Thought Technology Ltd. Options Menu ONLY NEED TO SET ONCE These need to be set only once; once they are set they will remain at your chosen setting until you modify them again
15
Thought Technology Ltd. Pacer Units
16
Thought Technology Ltd. Pacer Units Options: Pacer Units The pacer can either be set to seconds (real time) or percentages (proportion of time)
17
Thought Technology Ltd. Respiration Pacer Options in Infiniti 1. Seconds Breath for a length of time 2. Percentages Percentage of time at a rate Article on breathing and meditation
18
Thought Technology Ltd. Notch Filters Options: Notch filters Depending on your geographic region, set your notch filter to either 50 or 60Hz
19
Thought Technology Ltd. Notch Filter Options 50Hz in Australia Watch out for surrounding appliances
20
Thought Technology Ltd. Event Labels Options: Event Labels Set event labels here. Event labels can be used to mark data while recording as a reminder of what was happening in the session
21
Thought Technology Ltd. Event Labels
22
Thought Technology Ltd. Notch Filter Options 7 Day Dreaming 8 Sleeping 9 off in lala land
23
Thought Technology Ltd. Event Marker Labels ADD A NEW LABEL “checking out” Generate Report
24
Thought Technology Ltd. Event Marker Labels Press CONTROL AND THE LETTER OR THE NUMBER
25
Thought Technology Ltd. Main Screen Buttons Database to Replay a Session Click on the “Database” button to open the main database The database contains all of your clients and recorded sessions
26
Thought Technology Ltd. Select a Client & Session Database
27
Thought Technology Ltd. Replay Session
28
Thought Technology Ltd. Confidential Mode Database: selecting a client From the left hand column select a client This client list is in confidential mode, to remove confidential mode, go to options, and uncheck it
29
Thought Technology Ltd. Selecting a Session Database: selecting a recorded session Select a recorded session from the right hand column Note that the type of session is listed under “Type”
30
Thought Technology Ltd. Replay Session Database: Replay Session With a client and recorded session selected, click on Replay Session Select the desired channel set and screens and click on OK.
31
Thought Technology Ltd. Select Screens Database: Selecting Screens From picture mode you can see captures of the different screens. Note that some screens are two monitor (one screen for clinician, the other for client)
32
Thought Technology Ltd. Replay Session
33
Thought Technology Ltd. Replay Session
34
Thought Technology Ltd. Left and Right Axes
35
Thought Technology Ltd. Screen #1
36
Thought Technology Ltd. Artifacts
37
Thought Technology Ltd. Screen Anatomy Replay Mode: Heart Rate Variability Training Screen The training screen contains a number of graphs (bar and line), a frequency analysis, an epoch graph, sound, and a couple of animations.
38
Thought Technology Ltd. 64 Seconds for FFT Replay Mode: Heart Rate Variability Training Screen Note that the frequency calculations will not come into effect before 64 seconds of data have been recorded. Before this point, the values are not valid and thus are not shown
39
Thought Technology Ltd. Replay Mode Controls Replay Mode: Control Menu Press the Green Arrow to begin (Play) Press the Red Square to Stop Press the two Yellow Rectangles to Pause Press the numbered buttons to move through screens
40
Thought Technology Ltd. Time Scale Replay Mode: Time Scale To change the time scale, click on the drop down time menu and select your desired time scale Note that only line graphs will reflect this change
41
Thought Technology Ltd. Line Graph Replay Mode: Line Graph This line graph shows three different signals in different colours The signals are identified by the colours and labels above the graph
42
Thought Technology Ltd. Respiration Pacer Replay Mode: Pacer The breathing pacer allows the client to follow a pacer during respiration. Follow the ball up on inhale, and down on exhale
43
Thought Technology Ltd. Pacer Settings Replay Mode: Pacer The pacer can be modified to virtually any respiration rate: right click on the instrument and select “Edit Pacer Settings” A box appears and it is here that you can modify the settings
44
Thought Technology Ltd. F1 Help At All Times Replay Mode: F1 Help Menu At any time press F1 to bring up a topic specific help menu You can also search topics in the left hand column
45
Thought Technology Ltd. Animations Replay Mode: Animations Animations are to give visual feedback Animations can be continuous and move (circular or linear), or can be on or off (binary)
46
Thought Technology Ltd. Bar Graphs Replay Mode: Bar Graphs These bar graphs are set to an auto scale (continuously variable) and have thresholds (automatic thresholds) A small line graph beneath the bar graphs shows the raw signal
47
Thought Technology Ltd. FFT – Only after 64 secs Frequency Analysis (FFT) Graph blank for first 64 seconds Frequency Analysis (FFT) Graph blank for first 64 seconds
48
Thought Technology Ltd. FFT – 2 Dimensions Replay Mode: Frequency Analysis (FFT) The FFT (Fast Fourier Transformation) is a Frequency Analysis of the EKG IBI signal Note that the peak frequency changes colour for easy identification
49
Thought Technology Ltd. Epoch Graph Replay Mode: Epoch Graph This Epoch Graph can have both bar and line graphs (only bar shown below) and shows progress through a session (updates every 20 seconds) The vales are colour labeled and the last values are also shown as a numeric value at the top of the graph
50
Thought Technology Ltd. Numeric Display Replay Mode: Numeric The numeric instrument simply shows the numerical value of the current statistic Note that the number is often dampened (averaged or slowed) to ensure that it is easily readable
51
Thought Technology Ltd. Light and Tone Feedback
52
Thought Technology Ltd. Lesson 1 Review Thanks Any Questions? Homework for Lesson 1 Date & Time for Lesson 2 Lesson 1 Wrap Up
53
Thought Technology Ltd. Questions Lesson 1