PRACTICAL EXAMPLES OF THE ANALYSIS OF SEVERE ACCIDENTS Presented Dr. Chris Allison Regional Workshop on Evaluation of Specific Preventative and Mitigative Accident Management Strategies
2
Outline Analysis of SAs –Bundle boiloff – influence of SA models –Bundle quench CORA-13 – PWR – severe oxidation transient during reflood –TMI-2
3
Bundle Boiloff Two identical bundles –32 rods in 6X6 array – 0.91 m height –Boildown transient –High decay heat – 58.5 Kw (2.0 Kw/m per rod) One bundle modeled using RELAP5 heat structure – 1D heat conduction only One bundle modeled using SCDAP fuel rod component – 2D heat conduction, oxidation, ballooning and rupture, material liquefaction
5
Influence of SA models starting below 1500 K RELAP RELAP predicted temperatures SCDAP predicted temperatures Fuel rod temperature above midpoint Time (s)
6
Oxidation heat generation comparable to decay heat Decay heat Oxidation heat generation Power - Kw
7
Oxidation limited by Zr relocation Maximum temperature Hydrogen production – g/s Maximum bundle temperature - K Hydrogen production
8
Axial temperature distribution Bottom Top Temperature - K U-Zr-O relocation Dryout
9
Oxidation front starts above midpoint H2 generation rate – g/s Zr melt relocation
10
Ballooning and rupture occurs near 1000 K Hoop StrainTemperature
11
Zr-O-U Relocation to lower portion of bundle Fuel outer radius including frozen crust Temperature
12
CORA-13 PWR Quench Electrically heated PWR bundle –25 rods (16 fuel rods, 7 heated fuel rod simulators, 2 Ag-In-Cd control rods) –1.00 m heated length –Constant steam/argon flow
13
Oxidation heat generation during reflood >> electrical heating Decay heat Oxidation heat generation Power - Kw Quench Note: Electrical power shutdown prior to quench
14
Oxidation during reflood results in temperature excursion and renewed melting Maximum temperature Hydrogen production – g/s Maximum bundle temperature - K Hydrogen production Quench
15
Axial temperature distribution Bottom Top Temperature - K Renewed heating in upper bundle due to reflood
16
Oxidation of liquid U-O-Zr signficant during reflood H2 generation rate – g/s Zr melt relocation
17
Ballooning and rupture occurs near 1200 K Hoop StrainTemperature
18
Zr-O-U Relocation to lower portion of bundle Fuel outer radius including frozen crust Temperature Ballooning U-Zr-O freezing
19
TMI-2 The TMI-2 problem is described in the SCDAP/RELAP5/MOD3.2 reference manual (Volume V) –General description (Section 5.5) –Input model description (Appendix A.11) TMI-2 sample problem on CD includes –Restart plot file –Sample input file (restarting after B-pump transient and formation of initial molten pool) –Sample plot input file
20
TMI-2 Core Nodalization
21
Calculated peak core temperatures and pressures for TMI-2 B-pump Transient Core uncovery ECCS Injection Temperature Pressure
22
Rapid Zircaloy oxidation resulted in initial liquefaction and relocation of core metals Fuel temperatures Liquefaction of UO 2 and ZrO 2 Melting of Zr Control rod melt relocation, onset of rapid oxidation
23
B-Pump Transient resulted in sharp increase in oxidation in middle of core Peak core temperature Oxidation rate B-pump Transient
24
B-Pump transient cooled lower portion of core Fuel temperatures Axial nodes 3-5
25
Molten { (U-Zr)-O 2 } pool continued to grow after water injection B-pump Transient Molten pool radius in core
26
Molten (U-Zr)-O 2 relocates into LP after ECCS injection ECCS Injection Melt relocation into LP Temp. of melt in LP Height of debris in LP