1
ARAVIND EYE CARE SYSTEM A R A V I N D E Y E H O S P I T A L & Postgraduate Institute of Ophthalmology Madurai, India ARAVIND EYE CARE SYSTEM A R A V I N D E Y E H O S P I T A L & Postgraduate Institute of Ophthalmology Madurai, India Face Measurements R.D.Gopinath Supervisor – Optical Sales
2
A R A V I N D E Y E C A R E S Y S T E M Why Measure PDs ? Spectacle lens optical centres (OCs) should correspond to the wearer’s PD To avoid unwanted prismatic effect due to decentration especially in higher Rx powers Advanced lens designs must be positioned accurately
3
A R A V I N D E Y E C A R E S Y S T E M Principles in Measuring PDs PD rule (visual axes or pupil centres) Pupillometer (visual axes) Near centration distance
4
A R A V I N D E Y E C A R E S Y S T E M PD Measurement devices PD ruler. Pupillometer Pen torch
5
A R A V I N D E Y E C A R E S Y S T E M How to do it…
6
A R A V I N D E Y E C A R E S Y S T E M Binocular PDs The variation between the visual axes and pupil centres 60 61
7
A R A V I N D E Y E C A R E S Y S T E M Step 1 Step2 Subject Examiner 3020100 PD Rule Subject Examiner 3040506220100 PD Rule RE LE RELE RE LE RE LE Binocular Distance PDs
8
A R A V I N D E Y E C A R E S Y S T E M 3134 Why Monocular PD important? Wearers’ faces are not always symmetric.
9
A R A V I N D E Y E C A R E S Y S T E M PD rulers…
10
A R A V I N D E Y E C A R E S Y S T E M Monocular PDs PD Ruler Method Sit directly opposite the patient (arm’s length) Place ruler on the bridge of the patient’s nose Hold pen torch under your left eye directed at the patient’s RE
11
A R A V I N D E Y E C A R E S Y S T E M Monocular PD 29mm 32mm 61mm Monocular PDs Facial Fitting Principles PDs Corneal reflex pupillometer (visual axes)
12
A R A V I N D E Y E C A R E S Y S T E M Practitioner’s side Subject’s side Binocular PD Monocular PD Fast and accurate measurement for monocular and binocular PDs The Pupillometer
13
A R A V I N D E Y E C A R E S Y S T E M Subject’s view Practitioner’s view Pupillometer Ability to vary working distance from 20cm to infinity Procedure: Internal hairline moved until line and corneal reflection are coincident Corneal reflection typically located nasal to pupil centre (2 to 5 )
14
A R A V I N D E Y E C A R E S Y S T E M A pen torch will produce clear corneal reflections Direct Pupillary reflex marking method
15
A R A V I N D E Y E C A R E S Y S T E M Near Centration Distance Facial Fitting Principles PDs Near centration distance
16
A R A V I N D E Y E C A R E S Y S T E M RELE Centre of nose bridge to centre of cornea Spectacle Plane Subject Examiner LERE 40c m Binocular Near CDs
17
A R A V I N D E Y E C A R E S Y S T E M Near Centration Distance Distance PD Working distance 400 mm Centre of rotation to spectacle plane 27mm Near CD = 400 X Distance PD 427 Facial Fitting Principles Near centration distance The calculation
18
A R A V I N D E Y E C A R E S Y S T E M Sources of error taking PDs with the PD ruler Parallax: Practitioner does not close the non-observing eye practitioner and patient are not directly in line Incorrect ruler position: not straight or close enough to the spectacle plane, especially at near Significant differences in PDs of subject and examiner
19
A R A V I N D E Y E C A R E S Y S T E M Aspherics and Near CD Aberration or prismatic effect The principal axis should pass through the eye’s centre of rotation For near, this requires a distance PD Traditional setting for the OC for reading is the near CD Eg. Rx = +6.00D both eyes Add = +1.00D both eyes Readers set at distance PD = 2.8 base out Readers set at near CD = 0 Prism at near with bifocals = 2.4 base out
20
A R A V I N D E Y E C A R E S Y S T E M Face measurements To select the appropriate size frame. Temple length Length of drop / Ear piece. Bridge size. Intra temporal distance. Pantoscopic angle Vertex distance Segment height
21
A R A V I N D E Y E C A R E S Y S T E M Summary Frame & Face measurements are necessary to Avoid unwanted prismatic effect. Minimize the optical inherent defects. Better reading area (in bifocal) Correct fit on the face. Accurate PAL dispensing.
22
A R A V I N D E Y E C A R E S Y S T E M Thank You