1 Samsung Techwin Access Control Sales Presentation 2010

2 Contents Introduction to Access Control and User Credentials Standalone Controllers Control Panels Readers Accessories Part Codes System Configurations Appendix – Technical Data

3 Introduction Access control is a system which enables an authority to control access to areas and resources in a given physical facility. Conditions of granted access WHOM WHERE HOW WHEN Controlled Access Points Authorized Individuals Specific Time Parameters User Credentials

4 Introduction to Access Control Lock and Key Can secure a door. Key will always open lock, regardless of time. Lost key requires lock replacement. No audit of granted access. Bunches of keys are heavy to carry. Losing a bunch of keys requires many expensive lock changes Electronic Access Control Can secure a door. Time profiles can be added to access levels. Lost card key can be deactivated. Any card can open one or all doors. Full audit trail of successful and denied access. No need to replace working locks. Door monitoring to signal ‘Door Held’ or ‘Forced’ open. Credentials can be combined for higher levels of security, card key, PIN number, biometric.

5 Samsung Techwin Access Control - Credentials Low Physical / Tangible Object. Example – a card key. Med Something you know. Example - a PIN. High Something you have. Example – a fingerprint.

6 Samsung Techwin Access Control – Solutions Range  STANDALONE RANGE  Entry Level, single credential standalone.  Medium Secure, duel credential standalone.  High Security, triple credential standalone.  PC Connection possible for Time &Attendance readers.  SOFTWARE, INTELLEGENT CONTROLLERS AND READERS  Scalable software built on SQL Server 2005.  Distributed processing.  1,2,3 and 4 door intelligent control.  Proximity / Smart Card, PIN and Biometric Readers.  TCP/IP Networked.  Video Integration.  Command and Control.

7 Samsung Techwin Access Control The Samsung Access Control Range offers aesthetically designed products built to increasing design specifications to provide a cost effective security solution tailored to an individuals need and budget. The standalone range offers the most cost effective small system solution and has high security options, utilising fingerprint recognition in conjunction with PIN and proximity for the most secure environments. Beyond the standalone range is the Samsung Access Management System – SAMS – which is built on a SQL Server database structure and includes multiple communication protocols, video integration, command and control, reporting and language options for medium to large businesses.

8 What are Standalone Controllers? Standalone controllers: do not require a connection to a computer. can be programmed locally once the unit is installed and has power connected. card key administration can be performed locally at the device

9 Properties of Standalone Controllers Cost effective complete door control. Proximity / Smart Card, PIN, Password and Fingerprint options. Direct control of door lock. – Power Fail Safe / Power Fail Secure. Products to satisfy increased security needs with multiple user credential and vandal resistant options.

10 Standalone Controller Range SSA-S1000 SSA-S1000V SSA-S2000 SSA-S2000V SSA- S3010/3020/3040 SSA- S3011/3021/3041 SSA- S3010/3020/3040 SSA- S3011/3021/3041 SSA-S2100 SSA-S2101 SSA-S2100 SSA-S2101

11 Standalone Controller – SSA-S1000 / S1000V Proximity Access Controller Cost Effective Single Door Control Slim Aesthetic Design Ideal Small Business Application Vandal Resistant Option Features – Entry Level Access Control – Standalone (no application software required) – Up to 512 users – Power Fail Safe or Fail Secure lock type – Shadow Cards Vandal Resistant (V) Model – Weatherproof and Dustproof (IP68) Technical Data LinkTechnical Data Link Connection Diagram Link Setup Data LinkConnection Diagram Link Setup Data Link

12 Standalone Controller – SSA-S2000 / S2000V Proximity and PIN Access Controller Cost Effective Duel Technology Single Door Control Ideal Small Business Application Vandal Resistant Option Second (Exit) Reader Option Features – Proximity + PIN (options; prox only / PIN only) – Standalone (no application software required) – Up to 512 users – 5 x Inputs, 4 x Output - programmable – Duress Function – Power Fail Safe or Fail Secure lock type Vandal Resistant (V) Model – Weatherproof and Dustproof (IP66) Technical Data LinkConnection Diagram Link Setup Data Link

13 Standalone Controller – SSA-S2100 / S2101 Proximity / Smart Card & PIN, Time and Attendance Access Controller High Security Applications Time and Attendance Management Standalone + Networked Windows Reporting Application / Admin Second Reader Connection Features – Up to 20,000 Users and 20,000 Event Buffer – All combinations of Proximity Card, PIN and Password – 4 x Inputs, 4 x Output – programmable + time schedule – Arm / Disarm function and interface with Intruder Alarm – Time Schedules – Two Man Operation Mode – Duress Function – Power Fail Safe or Fail Secure lock type – Controller or Networked Software Administration Technical Data LinkConnection Diagram Link

14 Standalone Controller – SSA-S3010 / S3011 Series Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller Triple User Credential, including Biometric. High Security Applications Time and Attendance Management Standalone + Networked Windows Reporting Application / Admin Second Reader Connection Features – Up to 4000 Finger Print Users – All combinations of Finger Print Proximity Card, PIN and Password – 4 x Inputs, 4 x Output – programmable + time schedule – Arm / Disarm function and interface with Intruder Alarm – Time Schedules – Two Man Operation Mode – Duress Function – Power Fail Safe or Fail Secure lock type – Controller or Networked Software Administration Technical Data LinkConnection Diagram Link

15 Standalone Part Codes

16 Standalone Summary ModelKey FeatureApplication SSA-S1000Samsung 125KHz Proximity / 512 Users.Cost effective, entry level Access Controller. SSA-S1000V Samsung 125KHz Proximity / 512 Users. Vandal resistant. Cost effective, entry level Access Controller for higher physical risk areas. SSA-S2000Duel credential proximity and PIN / 512 users. Higher security areas requiring duel authentication. SSA-S2000V Duel credential proximity and PIN / 512 users. Vandal resistant. Higher security areas requiring duel authentication with high physical risk to the controller. SSA-S2100 Series Proximity / Smart Card + PIN, Time and Attendance. 20,000 users. Optional networked administration software. High level security applications requiring Time and Attendance, Anti Pass Back and Arm / Disarm functions. SSA-S3010 Series Finger Print Recognition + Proximity / Smart Card + PIN, Time and Attendance. 20,000 users. Optional networked administration software. Top level security applications requiring Biometric recognition, Time and Attendance, Anti Pass Back and Arm / Disarm functions. All models  Controlled Access  Lock Control  No software necessary Standalone controlled door access with lock control.

17 Standalone Controller – Questions?

18 Access Control Intelligent Controllers Intelligent door controllers provide distributed processing for the interface of access control readers, keypads, inputs and outputs back to a Host Computer.

19 Intelligent Controllers - Distributed Processing Distributed processing allows each intelligent controller to operate independent of the host computer with most of the decisions made at the controller. This provides instant response for door control and alarm sensing while leaving the host computer with more processing power for actions like alarm response and database updates.

20 Intelligent Controllers State-of-the-art Controllers at affordable prices Intelligent control of 1,2,3 or 4 Doors Communication: TCP/IP, RS232, RS485 / RS422 Data Continuity after power failure Programmable Inputs / Outputs Up to 50,000 users Up to 50,000 event buffer Wiegand compatible readers

21 Intelligent Controllers State-of-the-art Controllers at affordable prices Single Door Controller Small to Medium Business Safe non-volatile Flash Data Memory - for business continuity Duress Mode Function Site Arm / Disarm Function Single door controller Up to 50,000 users / 50,000 event buffer Versatile 5 input / 4 output Select TCP/IP, RS232, RS285 or RS422 communication Four Door Controller Medium to Large Business Safe non-volatile Flash Data Memory - for business continuity Duress Mode Function Site Arm / Disarm Function Up to four doors controlled Up to 50,000 users / 29,500 event buffer Versatile 15 input / 15 output Select TCP/IP, RS232, RS285 or RS422 communication Link to : Installation Network Configuration Serial CommunicationInstallationNetwork ConfigurationSerial Communication Four Door: Reader Connection Lock ConnectionReader ConnectionLock Connection Single Door: Reader Connection Input Connection Lock ConnectionReader ConnectionInput ConnectionLock Connection

22 Intelligent Controller – Questions? Link to : Installation Network Configuration Serial CommunicationInstallationNetwork ConfigurationSerial Communication Four Door: Reader Connection Lock ConnectionReader ConnectionLock Connection Single Door: Reader Connection Input Connection Lock ConnectionReader ConnectionInput ConnectionLock Connection

23 Readers Comprehensive range of readers to satisfy challenging security environments

24 Samsung have developed a range of highly aesthetic readers, which transmit user credentials to the Intelligent Controllers. Reader variations include Slim Line, Vandal Resistant, PIN Number and Biometric Fingerprint with a range of card technologies.

25 Readers – R1000 / R1100 Comprehensive range of readers to satisfy challenging security environments Elegant looking proximity / smart card / EM reader Read Range of 10cm Both units use the same weatherproof (IP66)epoxy moulding, so are interchangeable depending on the wall condition or aesthetic preference Can be installed on metal door frame or on a wall Wiegand output Link to Technical Specification Link to Wiring DiagramLink to Technical Specification Link to Wiring Diagram

26 Readers – R1000V / R1100V Comprehensive range of readers to satisfy challenging security environments Elegant looking proximity / smart card / EM reader which can be mounted on a metal door frame or on a wall. Vandal resistant with a high level of weatherproofing (IP68) for challenging environmental conditions Wiegand output Link to Technical Specification Link to Technical Specification Link to Wiring DiagramLink to Wiring Diagram

27 Readers – R2000 / R2000V Comprehensive range of readers to satisfy challenging security environments Elegant looking proximity / smart card / EM reader with back-lit keypad for PIN entry in dark conditions. Can be mounted on metal door frame or wall. Vandal option is IP68 and features the capacitive touch sensitive keypad Link to Technical Specification 2000Link to Technical Specification 2000 Link to Wiring Diagram 2000Link to Wiring Diagram 2000 Link to Technical Specification 2000VLink to Technical Specification 2000V Link to Wiring Diagram 2000VLink to Wiring Diagram 2000V

28 Readers – R2010 / R2011 Comprehensive range of readers to satisfy challenging security environments Fingerprint recognition and proximity / smart card reader for high security applications Auto touch sensor for fingerprint only recognition. Operating mode selectable by individual ID (RF Only, fingerprint only, RF + fingerprint) Link to Technical Specification Link to Technical Specification Link to Wiring DiagramLink to Wiring Diagram

29

30 Reader – Questions? Comprehensive range of readers to satisfy challenging security environments

31 Software Samsung Access Management Software SAMS Basic and SAMS Pro (Video Integration) have a free licence which has full functionality and includes the database engine (SQL Server 2005 Express) up to the level of 20 doors OR 100 users.

32 Software Samsung Access Management Software SAMS is a programmable, integrated, computer based security system software package that provides access control, alarm point monitoring, access control administration and monitoring to the rest of the hardware system. Windows based Server and Client, SAMS is menu driven and easy to use.

33 Software – SAMS Basic and Basic Lite Samsung Access Management Software Scalable access management software built on an SQL Server 2005. Dual Monitor support Integrated Monitoring with site map Easy In/Output control and monitoring with Door, Sensor, Alarm Icon on the site map Server (SAMS Basic)/ Client (Basic Lite) network configuration Software Architecture System Configuration 1 System Configuration 2

34 Software – SAMS Pro and Pro Lite Samsung Access Management Software Video Integration, Command and Control maps. Scalable access management software built on an SQL Server 2005. Dual Monitor support Integrated Monitoring with site map Easy In/Output control and monitoring with Door, Sensor, Alarm Icon on the site map Server (SAMS Pro)/ Client (Pro Lite) network configuration Software Architecture System Configuration 1 System Configuration 2

35 Software – Questions? Samsung Access Management Software Basic / Basic Lite Pro / Pro Lite Software Architecture System Configuration 1 System Configuration 2 Software Architecture System Configuration 1 System Configuration 2

36 Appendix / Technical Data SSA-S1000(V) - Connection Data / Setup Data / Technical Data SSA-S2000(V) – Connection Data / Panel Description / Card Registration / Setup / Technical Data SSA-S21XX / S30XX – Panel Description / Basic Installation / Network Diagram / Connection Data / Technical Data SSA-P4XX / P1XX – Intelligent Controller / Installation / Network Configuration / Serial Communications / SSA-P4XX Reader + RTE Connection / SSA-P4XX Lock Connection / SSA-P1XX Reader Connection / SSA-P1XX Input Connection / SSA-P1XX Lock Connection 1 Door Reader SSA-R1000 + R1100 / Connection Data / Technical Data Reader SSA-R1000V + R1100V / Connection Data / Technical Data Reader SSA-R2000 / Connection Data / Technical Data Reader SSA-R2000V / Connection Data / Technical Data Reader SSA-R2010 / 3010 Series / Connection Data / Technical Data Software – Basic / Architecture / System Configuration Software – Pro / Architecture / System Configuration

37 Exit Button DC 12V(+) Power Door Contact DeviceWiring Power Connect +12V of power supply to Red wire. Connect GND of power supply to Black wire. Door Sensor Connect COM terminal of door sensor to Blue wire of door sensor input. Connect NO terminal of door sensor to GND of power supply. Exit Button Connect Green wire of exit button input to one wire between wires of exit button. Connect GND wire of power supply to the other wire. Standalone Controller – SSA-S1000 / S1000V – Connection Data Proximity Access Controller BACK

38 Standalone Controller – SSA-S1000 / S1000V – Connection Data Proximity Access Controller Door Lock Alarm Device DC 12V(+) Power DeviceWiring Power Connect +12V of power supply to Red wire. Connect GND of power supply to Black wire. Door Lock Connect (+) wire of door lock to +12V wire of power supply. Connect (-) wire of door lock to white wire of reader module. Alarm Connect (+) wire of Alarm to +12V wire of power supply. Connect (-) wire of Alarm to purple wire of reader module. Lock Type Select In a power fail safe, connect GND wire of power supply to Yell ow wire of door lock type input. In a power fail secure, put a floating state on Yellow wire of d oor lock type input. BACK

39 Step 1 1) Turn the power off 2) Short White & Green & Yellow wire Step 2 1) Turn the power on 2) All red led will be turned on and off twice with buzzer 3) Turn the power off Step 3 1) Disconnect White & Green & Yellow wire 2) Turn power ON 3) Present the card that you wish to use as master card 4) Master card has been registered SSA-S1000 / S1000V Standalone Controller Standalone Controller – SSA-S1000 / S1000V – Setup Data Proximity Access Controller BACK

40 Standalone Controller – SSA-S1000 / S1000V – Technical Data Proximity Access Controller BACK

41 DC +12V(Red) GND (Black ) Power Exit Button Yellow with Red stripe Door Contact Connection Green COM NC NO COM NO GND (Black ) PIR Sensor IN#1(Orange) IN#2(Green with White stripe) IN#3(Brown) GND(Black ) PIR Sensor Auxiliary Input #1~#3 SSA-S2000 / S2000V Standalone Controller Standalone Controller – SSA-S2000 / S2000V – Connection Data Proximity and PIN Access Controller BACK

42 NO(Blue with White stripe) NC(White with Red stripe) NO (Purple) NC(Purple with White stripe) COM (White) X Alarm - + Alarm Connection Door Lock GND (Black ) DC+12V(Red ) DC+12V Power - + POWER FAIL SAFE POWER FAIL SECURE DC+12V(Red ) GND (Black ) Exit Reader GND (Black ) DC+12V(Red ) DATA0(Pink ) DATA1(Cyan ) DATA0(Pink ) * Connection of POWER FAIL SAFE: Door Lock * Connection of POWER FAIL SECURE: Door Lock COM(Gray with Red stripe) DATA1(Cyan ) SSA-S2000 / S2000V Standalone Controller Standalone Controller – SSA-S2000 / S2000V – Connection Data Proximity and PIN Access Controller BACK

43    When the Main Unit operates in Selection Mode, LED  is flashing.  When a registered Card (or PIN) is read or exit button is pressed, LED  will be on for 3 seconds along with the "do-mi-sol-do" melody, and Lock will be opened. When an unregistered Card (or PIN) is read, LED  will be on for 2 seconds along with the "sol-do-sol-do" melody. When the Main Unit operates in normal mode LED is flashing every second. Keypad LED Indicator SSA-S2000 / S2000V Standalone Controller Standalone Controller – SSA-S2000 / S2000V – Front Panel Description Proximity and PIN Access Controller BACK

44 Step 1 1)Turn the power off 2)Short Green & Orange with white stripe wires 3)Turn the power on 4)3 color LED blinking with beep sound indicates the success of initialization. Step 2 1)Disconnect Orange & Orange with white stripe wires 2)3 color LED keep blinking (Initial Mode) Step 3 1) Select the Operation Mode - Card Only (0,1,ENT) - Card + PIN (0,2,ENT) - PIN Only (0,3,ENT) - Card / PIN Combination (0,5,ENT) 2) Present the card that you wish to use as master card 3) Register Users or Present Master card again to exit registration Mode Master Card User Access Cards or PINs SSA-S2000 / S2000V Standalone Controller Standalone Controller – SSA-S2000 / S2000V – Master Card Registration Proximity and PIN Access Controller BACK

45 Initial Setup is required upon the first time the unit is powered-up in order to operate the unit properly. 1) Registration of RF Cards for RF CARD ONLY MODE 2) Registration of RF Cards with PINs for RF CARD + PIN MODE 3) Registration of PIN ONLY MODE 4) Registration of RF/PIN Combination MODE 1) Registration of RF Cards for RF CARD ONLY MODE2) Registration of RF Cards with PINs for RF CARD + PIN MODE (1) Apply 12VDC to the unit. All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~). (2) Press ‘0’,’1’,’ENT’ from the keypad. (RF CARD ONLY MODE ) (3) Present RF Cards as follow to register Master Card and User Access Cards. (1) Apply 12VDC to the unit. All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~). (2) Press ‘0’,’2’,’ENT’ from the keypad. (RF CARD + PIN MODE ) (3) Present RF Cards as follow to register Master Card and User Access Cards + 4~6 digit Personal Identification Number (PIN) for each User Access Card. (4) The first card read becomes the Master Card and the following RF Cards are registered as User Access Cards. Once all User Access Cards have been registered, present the Master Card again to complete the registration. (Please keep the Master Card in a secure location for future changes.) (5) Now, the Main Unit is entered into the normal operation mode with factory defaulted settings. (4) The first card read becomes the Master Card and the following RF Cards + PINs are registered as User Access Cards with assigned PINs. Once all User Access Cards and PINs have been registered, present the Master Card again to complete the registration. (Please keep the Master Card in a secure location for future changes.) (5) Now, the Main Unit is entered into the normal operation mode with factory defaulted settings. Master CardUser Access CardsMaster Card again to end task Master Card User Access Cards + PINs Master Card again to end task SSA-S2000 / S2000V Standalone Controller Standalone Controller – SSA-S2000 / S2000V – Initial Setup Proximity and PIN Access Controller BACK

46 3) Registration of PIN ONLY MODE4) Registration of RF/PIN Combination MODE (1) Apply 12VDC to the unit. All 3 LEDs will be flashing along with a powered-up melody (do mi sol me do..do mi sol do~). (2) Press ‘0’,’3’,’ENT’ from the keypad. (PIN ONLY MODE) (3) Enter 4~6 digit PIN+’ENT’ to register Configuration PIN then 4~6 digit PIN+ ‘ENT’ to register for each subsequent User Access PIN at a time and then enter the 4~6 digit PIN+’ENT’ (Configuration PIN) to complete the registration. (1) Apply 12V DC to the unit. All 3 LEDs will be flashing with a power-up melody. (2) Press ‘0’,’5’,’ENT’ from the keypad. (RF/PIN Combination Mode) (3) Present Master Card to register Master Card to the unit. (4) The first 4~6 digit PIN becomes the Configuration PIN and the subsequent 4~6 digit PINs are registered as User Access PINs. Once all User Access PINs have been registered, enter the Configuration PIN again to complete the registration. (Please store the Configuration PIN for future changes.) (5) Now, the Main Unit is entered into the normal operation mode with factory defaulted settings. (4) Present RF Card or enter 4~6 digit PIN number to register user access card or PIN. (5) Present Master Card to complete the registration Please refer to Summary Table of Commands for configuring functions Caution Configuration PIN User Access PIN Configuration PIN again to complete the registration. Master Card User Access Cards or PINs SSA-S2000 / S2000V Standalone Controller Standalone Controller – SSA-S2000 / S2000V – Initial Setup Proximity and PIN Access Controller BACK

47 NoCommandAction/Change setting valuesNoCommandAction/Change setting values 111Add User Access Cards (RF CARD ONLY MODE)3148Disable Unlock followed by Door Contact 212Add User Access Cards and PIN (RF CARD + PIN MODE)3251 Disable Melody sound (turning off both the melody & key press audio feedback) 313Add User Access PIN numbers (PIN ONLY MODE)3352Enable Melody sound 414Delete User Access Cards (or PIN)3460Change keypad lock-out time when Try-Out error detected 515Add User Access Card/PIN (RF/PIN Combination Mode)3561Set Aux Input #1 Detection from ‘L’ to ‘H’ 621 Change Door open time when User Access Card (or PIN) is granted 3662Set Aux Input #1 Detection from ‘H’ to ‘L’ 722Change Alarm time when User Access Card (or PIN) is denied3763Set Aux Input #2 Detection from ‘L’ to ‘H’ 823Change Alarm time when Try-Out error detected3864Set Aux Input #2 Detection from ‘H’ to ‘L’ 924Change Alarm time when Door-Contact error detected3965Set Aux Input #3 Detection from ‘L’ to ‘H’ 1025Change Alarm time when Aux Input #1 detected4066Set Aux Input #3 Detection from ‘H’ to ‘L’ 1126Change Alarm time when Aux Input #2 detected4167Set Exit Button Input Detection from ‘L’ to ‘H’ 1227Change Alarm time when Aux Input #3 detected4268Set Exit Button Input Detection from ‘H’ to ‘L’ 1328reserved4369Set Door-Contact sensor Input Detection from ‘L’ to ‘H’ 1429Register 2 digits Duress Alarm password4470Set Door-Contact sensor Input Detection from ‘H’ to ‘L’ 1530Change Alarm time when Duress Alarm detected4571Activate TTL output to ‘H’ 1631Test Door open time set by command "21"4672Activate TTL output to ‘L’ 1732Test Alarm time set by command "22"4773Enable Keypad Input To Enter ID Number 1833Test Alarm time set by command "23"4874Disable Keypad Input To Enter ID Number 1934Test Alarm time set by command "24"4977Enable Chime Bell Output 2035Test Alarm time set by command "25"5078Disable Chime Bell Output 2136Test Alarm time set by command "26"5180Set delay time to activate SECURE MODE 2237Test Alarm time set by command "27"5281Set Door Open time-out for Door-Contact sensor 2339Change Chime Bell activating time5382Set number of times of Try-Out 2441Open door unconditionally5483Set input key press time-out time 2542Close door unconditionally5584Set Tamper Alarm output port 2643Enable QUICK ACCESS MODE5688Enable Tamper Alarm 2744Disable QUICK ACCESS MODE5789Disable Tamper Alarm 2845Enable Toggle Mode for Lock control5899Re-Initialize and erase all setup data 2946Disable Toggle Mode for Lock control 3047Enable Unlock followed by Door Contact Standalone Controller – SSA-S2000 / S2000V – Initial Setup BACK

48 Standalone Controller – SSA-S2000 / S2000V – Technical Data Proximity and PIN Access Controller BACK

49 ① ② ③ ④ ⑤ ① ② ③ ④ SSA-S30xx SeriesSSA-S210x Series LCD Display Keypad Function keys LED Indicators Fingerprint scanner LCD Display Keypad Function keys LED Indicators SSA-S30xx / SSA-S210x Standalone Controller Standalone Controller – SSA-S30xx / S21xx Series – Panel Description Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller BACK

50 SSA-S30xx / SSA-S210x Standalone Controller Door Contact Management Software Dedicated / Integrated Exit Button Door Lock EXIT Power +12V DC GND Standalone Controller – SSA-S30xx / S21xx Series – Basic Installation Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller BACK

51 SSA-S30xx / SSA-S210x Standalone Controller Standalone Controller – SSA-S30xx / S21xx Series – Network Diagram Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller BACK

52 Black - Red + Wiegand DATA 0 (Pink wire) Wiegand DATA 1 (Cyan wire) Door contact Exit Button Black - Red + Power : DC 12V(+) SSA-S30xx / SSA-S210x Standalone Controller Door contact: Yellow with Red stripe wire & GND Exit Button: Orange wire & GND 2.2KΩ connection for cut-off checking Wiegand DATA 0 : Pink wire Wiegand DATA 1 : Cyan wire Standalone Controller – SSA-S30xx / S21xx Series – Connection Data Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller BACK

53 Door Relay COM (Gray with white stripe wire ) NO ( White with Red stripe wire ) NC ( Blue with white strip wire ) Alarm Relay COM ( White wire ) NO ( Purple ) NC ( Purple with white stripe wire ) Black - Red + SSA-S30xx / SSA-S210x Standalone Controller Standalone Controller – SSA-S30xx / S21xx Series – Connection Data Finger Print Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller BACK

54 Standalone Controller – SSA-S21XX Series – Technical Data Proximity / Smart Card & PIN, Time and Attendance Access Controller BACK

55 SSA-S30xx / SSA-S210x Standalone Controller Standalone Controller – SSA-S30xx Series – Technical Data Fingerprint Recognition, Proximity / Smart Card & PIN, Time and Attendance Access Controller BACK

56 Reader Card / Keypad / Biometric Control Panel RS485 / TCP/IP Door Contact EXIT Management Software Dedicated / Integrated Exit Button Door Lock Power AC 90~250V 50/60Hz SSA-P42xx / P40xx / P112x / P102x Control Panel Intelligent Controllers Basic Installation Diagram BACK

57 SSA-P42xx / P40xx / P112x / P102x Control Panel Intelligent Controllers Network Configuration Diagram BACK

58 Cross Connect Converter to controller TX(-)↔ RX(-) TX(+)↔ RX(+) RX(-)↔ TX(-) RX(+)↔ TX(+) Direct Connect Controller to controller TX(-)↔ TX(-) TX(+)↔ TX(+) RX(-)↔ RX(-) RX(+)↔ RX(+) SSA-P42xx / P40xx / P112x / P102x Control Panel Intelligent Controllers Serial Communications BACK

59 SSA-P42xx / P40xx Control Panel Reader Power sources can be used separately, but GND has to be wired together. In the case of separate wiring, due to voltage level difference, communication error can be happened. All reader ports should be wired in the same way. READER DATA 0 (Green) +12V (Red) DATA 1 (White) GND (Black) EXIT Exit Button Intelligent Controllers SSA-P4XX Connection Diagram for Reader & Exit Button BACK

60 Intelligent Controllers SSA-P4XX Connection Diagram for Door Lock Power Fail Secure - Power off  Lock - Power on  Unlock Power Fail Safe - Power off  Unlock - Power on  Lock Relay Output #1 & #3 are set up for door lock as default value In the case of Power off, if door is locked, the lock is called ‘Power Fail Secure Lock’. Cathode Anode 1N4004 ~ 1N4007 BACK

61 Separate power for readers can be also connected, but two power line should be connected to the same ground otherwise communication error may occur due to different level of voltage. Reader #1 Reader #2 Intelligent Controllers SSA-P1XX Connection Diagram for Reader BACK

62 Exit Button Door Contact INPUT #1 is for Exit button and INPUT #2 is for Door Contact. #3 ~ #5 is user selectable. EXIT Intelligent Controllers SSA-P1XX Connection Diagram for Input BACK

63 According to lock activation mode, there are NO/NC types and wiring should be done accordingly. Using reverse diode is recommended to prevent electric surge when lock is activated. Normal Open Normal Close Intelligent Controllers SSA-P1XX Connection Diagram for Door Lock l BACK

64 Readers – R1000 / R1100 – Connection Data BACK

65 Readers – R100X / R110X – Technical Data BACK

66 Readers – R1000V / R1100V – Connection Data Comprehensive range of readers to satisfy challenging security environments BACK

67 Readers – R1000V / R1100V – Technical Data BACK

68 Readers – R2000 – Connection Data Comprehensive range of readers to satisfy challenging security environments BACK

69 Readers – R2000 – Technical Data BACK

70 Readers – R2000V – Connection Data Comprehensive range of readers to satisfy challenging security environments BACK

71 Readers – R2000V – Technical Data Comprehensive range of readers to satisfy challenging security environments BACK

72 SSA-R20xx Biometric Reader TCP/IP connection is only for the uploading / downloading the fingerprint data. Readers – R2010 Series – Connection Data BACK

73 Readers – R2010 Series – Technical Data Comprehensive range of readers to satisfy challenging security environments BACK

74 SAMS Basic SAMS Basic Lite Application & Database Access Controller (Hardware) SAMS Basic Communication Server SSA-P40x/SSA-P102 SSA-S30xx/210x/SSA-R20xx Communication Server Database Server (Microsoft SQL Server 2005) Serial Communication TCP/IP TCP/IP Software - Basic - Architecture Samsung Access Management Software BACK

75 TCP/IP TCP/IP or Serial Loop Database (MS SQL) Application (SAMS Basic or SAMS Basic Lite) Comm. Server Support up to 10 Application Support up to 10 Comm. Server Support up to 100 Loop Support up to 32 Controller (if Serial Loop) Support up to 4 Door (if SSA-P42xx) With one system(Database), support up to 10 (Comm. Server) x 100 (Loop) x 1 (Controller) x 4 Doors = 4,000 Doors Software – Basic - System Configuration Samsung Access Management Software BACK

76 Branch Office #2 Branch Office #1 Head Office Head Office Database Server (MS SQL Server) Serial Communication SAMS Basic Comm. Server SAMS Basic (SSA-M1000) Serial Communication Internet (Backbone, WAN) TCP/IP Network (LAN) SSA-P112 SSA-P420TSSA-S3010SSA-S2100 SAMS Basic Lite (SSA-M1100) SAMS Basic Lite (SSA-M1100) SAMS Basic (SSA-M1000) SAMS Basic Lite (SSA-M1100) Serial Communication SSA-P420 SSA-S3010SSA-S2100 SSA-P112 SSA-S3010SSA-S2100 SAMS Basic Lite (SSA-M1100) SAMS Basic (SSA-M1000) SSA-P420 SAMS Basic Comm. Server SAMS Basic Comm. Server Software - Basic Samsung Access Management Software BACK

77 SAMS Pro SAMS Pro Lite Application & Database Access Controller (Hardware) SAMS Basic Communication Server SSA-P40x/SSA-P102 SSA-S30xx/210x/SSA-R20xx Communication Server Database Server (Microsoft SQL Server 2005) Serial Communication TCP/IP TCP/IP DVR (SHR, SRD Series) TCP/IP Software – Pro - Architecture Samsung Access Management Software BACK

78 TCP/IP TCP/IP or Serial Loop Database (MS SQL) Application (SAMS Pro or SAMS Pro Lite) Comm. Server Support up to 10 Application Support up to 10 Comm. Server Support up to 100 Loop Support up to 32 Controller (if Serial Loop) Support up to 4 Door (if SSA-P42xx) With one system(Database), support up to 10 (Comm. Server) x 100 (Loop) x 1 (Controller) x 4 Doors = 4,000 Doors No limitation with DVR Connection Up to 8 video channel can be monitored simultaneously Software – Pro - Configuration Samsung Access Management Software BACK

79 Branch Office #2 Branch Office #1 Branch Office #1 Head Office Database Server (MS SQL Server) SAMS Pro Comm. Server Serial Communication SAMS Pro (SSA-M2000) Serial Communication Internet (Backbone, WAN) SSA-P112 SSA-P420TSSA-S3010SSA-S2100 SAMS Pro Lite (SSA-M2100) SAMS Pro Lite (SSA-M2100) SAMS Pro (SSA-M2000) SAMS Pro Lite (SSA-M2100) Serial Communication SSA-P112 SSA-S3010SSA-S2100 SSA-P112 SSA-S3010SSA-S2100 SAMS Pro Lite (SSA-M2100) SAMS Pro (SSA-M2000) SAMS Pro Comm. Server TCP/IP Network (LAN) CCTV System SAMS Pro Comm. Server CCTV System TCP/IP Network(LAN) Software – Pro - Configuration Samsung Access Management Software BACK

80 END HERE Rest not used


Download ppt "Samsung Techwin Access Control Sales Presentation 2010."