City of Palm Beach Gardens ARTISTIC BUS SHELTERS ARTISTIC BUS SHELTERS ITB2014-039PW ITB2014-039PW
2
Basic Elements of Project Design, engineer, manufacture/fabricate, and deliver bus shelter to site Design, engineer, manufacture/fabricate, and deliver bus shelter to site Manufacture the pan formed metal artwork inserts per the three (3) designs provided by City; Manufacture the pan formed metal artwork inserts per the three (3) designs provided by City; Provide full signed and sealed engineering drawings by a registered engineer in the state of Florida for both the bus shelter and the required foundation Provide full signed and sealed engineering drawings by a registered engineer in the state of Florida for both the bus shelter and the required foundation Deliver Bus shelter to City within 10 miles of the following address; Deliver Bus shelter to City within 10 miles of the following address; 10500 N Military Trail Palm Beach Gardens, Fl. 33408 Supply all installation and construction manuals and other required technical data. Supply all installation and construction manuals and other required technical data. Supply all required warranty information Supply all required warranty information Optional Solar panel and light Optional Solar panel and light Bidder is not installing bus shelter Bidder is not installing bus shelter
3
Design Requirements The roof shall be standing seam metal hip with 6” fascia panel and a 24” soffit panel or approved equal. The roof shall be standing seam metal hip with 6” fascia panel and a 24” soffit panel or approved equal. The glass panels shall be ¼” clear tempered safety glass or approved equal. The glass panels shall be ¼” clear tempered safety glass or approved equal. All metal components of the shelter construction shall be powdered coated (color to be determined by City). All metal components of the shelter construction shall be powdered coated (color to be determined by City). All framing shall be aluminum tubing with sufficient size to meet the Florida Building Code requirement for wind load with the City of Palm Beach Gardens. All framing shall be aluminum tubing with sufficient size to meet the Florida Building Code requirement for wind load with the City of Palm Beach Gardens. An alternate bid item for solar lighting shall be provided inside the shelter with a photo cell and/or motion detector options. Battery size sufficient to run the light a minimum of 6 hours without sunlight. An alternate bid item for solar lighting shall be provided inside the shelter with a photo cell and/or motion detector options. Battery size sufficient to run the light a minimum of 6 hours without sunlight. All components of the shelter must be weather and vandal resistant. All components of the shelter must be weather and vandal resistant.
5
Size of Proposed Shelters 2’ Overhang A 10-foot long by 5 foot wide by 8 foot tall shelter must have an 18" deep bench seat at each end, and a minimum of 2 foot roof over hang on all sides.
6
Notes and Details
7
Artistic Inserts and Decorative Conner Brackets
8
Artistic Inserts
9
Fastener Details
11