Presentation is loading. Please wait.

Presentation is loading. Please wait.

August 22, 2012 Dave Jones & Mike Gruenberg. The Odor Complaint Viewer (OCV) is a tool for Dispatch to monitor odor calls/complaints The system will.

Similar presentations


Presentation on theme: "August 22, 2012 Dave Jones & Mike Gruenberg. The Odor Complaint Viewer (OCV) is a tool for Dispatch to monitor odor calls/complaints The system will."— Presentation transcript:

1 August 22, 2012 Dave Jones & Mike Gruenberg

2

3 The Odor Complaint Viewer (OCV) is a tool for Dispatch to monitor odor calls/complaints The system will graphically display odor and priority/emergency orders  Automatically posted when created in our customer information system  Manually posted for all other odor complaints New orders posted to the map will appear as a bull's-eye Previous orders will appear as either a red flag or red push-pin as clear visual reference

4

5

6 The dispatcher will enter the address, city & state OR the cross streets. Verify the date range – three-months Evaluate the area around the new order  Check the attributes of the push-pins and flags within a 500 ft. radius.

7

8

9 If there are flags and/or pins and these orders were all inside odor complaints that showed repair, turn off, etc., and the underground leakage investigation was negative, then no further action is required for those addresses If the object on the map was a flag and the order was an outside odor call, then these addresses require an automatic recheck of the facilities Any pins that show no resolution, either research the original order to find the resolution and input that information into the system or route the address for a recheck

10

11 Sometimes an order will come in where there is no address in our customer information system, such as an intersection, all electric, propane address, etc. The dispatcher can add a location by two different methods  Type in the address if known  Click a location on the map and the Latitude/Longitude fields will be populated for the location

12 Computer generated orders will automatically update with field technician comments when completed Manually input odor locations must be updated by the dispatcher

13

14 Zoom into a specific area Determine the distance between two points Identify the boundaries of an outage Identify restoration within the outage boundary

15

16 To investigate the report of a natural gas odor or possible leak Company representatives respond to all reports of:  Natural gas leakage  Suspected leakage or odor complaints  Miscellaneous hazards relating to natural gas and/or natural gas appliances

17 Detection Methods Leak Migration Behavior Soil Types Policy Investigation Procedures  Training/Qualification Evacuation Procedure

18 Responding personnel will only perform procedures for which they have been trained and are qualified A leak investigation will not end until the leak/odor has been either:  Repaired, eliminated and/or graded/classified  Positively determined NOT to be natural gas

19 360° Leak Investigation Procedure Conduct the leak investigation by using a Search or Confirmation Instrument from the base of the structure to a point approximately 5 ft away from the base of the structure

20 General Two types of leakage instruments used:  Search  Confirmation Three types of Outdoor Leak Investigations:  Intersection  Single Family Residential or structure less than 250 feet wide  All others What to do when leakage is found

21 Types of instruments used  Search Instrument – Rover (only)  Confirmation Instrument Two types of Indoor Leak Investigations: 1- Inside structure and access is available 2- Inside structure and access is NOT available

22 Upon entering any structure on any leak/odor investigation, a Confirmation Instrument will be used to:  Check for the presence of gas inside  This is to provide for an early warning in the event there is gas buildup inside the structure FI units must not be used inside buildings, confined spaces or any structure or substructure where gas may accumulate. FI units are not intrinsically safe.

23

24 Dave Jones 602-395-4488 Dave.jones@swas.com Mike Gruenberg 702-668-6401 Michael.gruenberg@swgas.com


Download ppt "August 22, 2012 Dave Jones & Mike Gruenberg. The Odor Complaint Viewer (OCV) is a tool for Dispatch to monitor odor calls/complaints The system will."

Similar presentations


Ads by Google