Download presentation
Presentation is loading. Please wait.
Published byGeraldine Hancock Modified over 9 years ago
1
CNT-BASED THERMAL CONVECTIVE ACCELEROMETER Presented by Yu ZHANG. Supervised by Prof. Wen J. LI
2
O UTLINE Introduction Literature Review Sensor Design Test Setup Test Results Conclusion 2
3
INTRODUCTION Literature Review Sensor Design Test Setup Test Results Conclusion 3
4
I NTRODUCTION Background The method to align post grown Carbon-Nanotubes between microelectrodes using dielectrophoretic (DEP) forces was developed in CMNS. 2003 Experiments showed CNT bundles can detect environmental temperature change. 2004 When heated within liquid, CNTs can generate thermal vapor bubble around itself. 2007 4
5
I NTRODUCTION Idea Acceleration/tilting will lead to deformation of the vapor bubble. Temperature distribution around the bubble will change If other CNT bundles can be fabricated around the bubble, they can sense the temperature change caused by acceleration. 5
6
I NTRODUCTION Aim of Research CNT-based thermal accelerometer Review the working principle of thermal motion sensor Choose applicable principle, design the structure Fabricate sensor chips, build prototypes Purchase and set up test equipments Test and characterize sensors’ response 6
7
LITERATURE REVIEW Introduction Sensor Design Test Setup Test Results Conclusion 7
8
L ITERATURE R EVIEW 8 Literature Review: Contents Motion Sensors Thermal Motion Sensors Carbon-Nanotube Manipulation Carbon-Nanotube Sensors
9
L ITERATURE R EVIEW Review of Motion Sensors Convert motion into electric signal Linear motion: accelerometer/inclinometer Angular motion: gyroscope Application in industry, consumer electronics, input devices, instruments Inclination: automobile stability, platform stabilization Orientation: gesture recognition, inertial navigation, active control Vibration: active suspension system, machine noise detection Shock: air bag system, release systems, structure monitoring 9
10
L ITERATURE R EVIEW Piezoresistive Conventional Motion Sensors Piezoelectric Capacitive 10 Acceleration Moving/bending of solid structure Change of detector output Convert to electric signal
11
L ITERATURE R EVIEW Pros Easy to design and model Standard IC process * Good cost/performance ration Fast response Cons Rely on solid moving parts: proof mass Better sensitivity requires bigger proof mass Fragile, cannot measure large acceleration (<20g) Low shock survival rate 11 * for surface micromachined sensors only Acceleration Move/bending of solid structure Change of detector output Convert to electric signal replacement for this step?
12
L ITERATURE R EVIEW Thermal convective motion sensor Details Acceleration will lead to forced convection of liquid within sealed chamber Use flow sensors to detect the flow speed caused by convection 12 Acceleration Convection of liquid Change of detector output Convert to electric signal Figure from [6]
13
L ITERATURE R EVIEW Anemometer Micro Flow Sensors Calorimetric flow sensor Time-of-flight flow sensor 13 Based on thermal phenomenon: Add local heat to fluid, measure the resulting temperature Very small Reynolds Number Laminar flow heat transfer Three sensing methods
14
L ITERATURE R EVIEW Research on Thermal Convective Accelerometer First reported in 1997 Research groups in Canada, US, France, Germany, China. Commercial products by MEMSIC. Inc. Based on integrated thermal flow sensor, to sense convection caused by acceleration. Up to two sensing axis 14 AccelerationConvection of liquidThermal detectorConvert to electric signal
15
L ITERATURE R EVIEW Working Principle One-axis Structure Two-axis Structure 15 Figure from….
16
L ITERATURE R EVIEW Carbon-Nanotubes Allotropes of carbon with a cylindrical nanostructure Single-walled and Multi-walled Synthesis method: arc discharge, laser ablation, chemical vapor deposition 16 CNT Integration Selectively grow on desired position In situ CVD Manipulate post-grew CNTs Use AFM tips to move Fluid friction Dielectrophoretic (DEP) force
17
L ITERATURE R EVIEW Review of CNT Sensors Mechanical sensors, chemical sensors, thermal sensors, pressure sensors Sensing method: Raman spectrum shift Performance change as circuit elements Resonators Transistors Resistance change Deformation Temperature Chemical reaction 17 Possible for micro sensors Reported by CMNS and other research groups
18
Literature Review: Conclusion Build the sensor upon thermal convection sensing principle Follow and improve the DEP manipulation method Deposited CNT bundles work as Temperature Detectors 18
19
SENSOR DESIGN Introduction Literature Review Test Setup Test Results Conclusion 19
20
20 Sensor Design: Contents Important Questions Mask Design Fabrication Sensor Prototyping
21
S ENSOR D ESIGN Important Design Questions Project requirement consideration The structure should be DEP compatible Sensing structure: Anemometer Calorimetric structure Time-of-flight structure No conditioning and feedback circuit MEMS structure consideration Thermal insulation 21 selected structure
22
S ENSOR D ESIGN Thermal Insulation Where to insulate (minimize heat flux) Between heater and detectors Between the sensing block and the substrate Better thermal insulation leads to Higher heater temperature Better sensitivity 22
23
S ENSOR D ESIGN Benefits of Thermal Insulation 23 substrate flow Q T detector T substrate > T detector brings away heat R detector heat from substrate Better thermal insulation Minimize heat capacitance of the substrate Reduce heat flux from substrate Improve sensitivity
24
S ENSOR D ESIGN Bridge Structure Insulation Layer Etched Cavity Membrane 24 Top view Side view
25
S ENSOR D ESIGN Thermal Insulation Design MaterialSiliconPorous SiliconGlassAir κ (Wm -1 K -1 )1251.1*1.20.025 25 Use glass as substrate Good thermal insulation result Fabrication process available Simple structure Need Cr layer to improve adhesion Cannot integrate with IC * From Reference [12]
26
S ENSOR D ESIGN Sensor Chip Mask Design Mask Layout Sensing Block 26 One pair of electrodes -> anemometer structure One CNT bundle as heater/detector Three pairs of electrodes -> calorimetric structure (1-axis) One CNT bundle as heater, two as detectors Five pairs of electrodes -> calorimetric structure (2-axis) One CNT bundle as heater, four as detectors One 1-axis calorimetric structure Three anemometer structure
27
S ENSOR D ESIGN Sensor Chip Fabrication 27
28
S ENSOR D ESIGN CNT Manipulation Multi-walled CNTs are used Disperse MWNT into ethanol Separate bundles using ultrasonic Drop 2μL above the electrodes Apply 8V peak-peak, 1MHz AC, from signal generator Improved DEP Circuits Captured Microscope Image 28
29
S ENSOR D ESIGN Sensor Building Processes 29
30
S ENSOR D ESIGN Prototypes 30
31
TEST SETUP Introduction Literature Review Sensor Design Test Results Conclusion 31
32
T EST S ETUP Source and Measure Test Circuit Source meters 32 Use Source & Measure Units (SMUs) to power up and measure. Keithley 2400 Sourcemeter: 1 SMU Keithley 2600 Sourcemeter: 2 SMUs Sourcemeters linked together to computer via GPIB Sourcemeter data synchronized by collected time stamps Constant current configuration
33
T EST S ETUP Tilting Plate Test Setup Vibration Exciter Test Setup 33
34
TEST RESULTS Introduction Literature Review Sensor Design Test Setup Conclusion 34
35
T EST R ESULTS 35 Test Results: Contents Thermal Sensing Test Tilting Test Vibration Test
36
T EST R ESULTS Thermal Sensitivity Tested in Climatic Chamber. Fixed humidity. Higher temperature -> Smaller resistance: Negative TCR 36
37
T EST R ESULTS Self-heating Test 37
38
T EST R ESULTS Temperature Change Caused by Heater 38
39
T EST R ESULTS 39 Test Results: Contents Proving Test Tilting Test Vibration Test
40
T EST R ESULTS Tilting Test Tested on tilting plate Anemometer structure with air sealed: No response Anemometer structure with liquid sealed: No response Calorimetric structure with air sealed: No response Calorimetric structure with liquid sealed: 40
41
T EST R ESULTS Tilting Test Configuration Convection medium: ethanol Input power heater: 6μW detectors: 1nW each Result Two sensors give opposite responses. Very good sensitivity. Very small power consumption Liquid convection medium 41 Conventional thermal accelerometers: 0.2mW to 480mW* *Table 2.2, Page 24, Thesis
42
T EST R ESULTS 42 Test Results: Contents Proving Test Tilting Test Vibration Test
43
T EST R ESULTS Vibration Exciter Calibration Use laser vibrometer to measure velocity, then calculate acceleration Fixed input power, varying input frequency. Frequency limited by Sourcemeter sampling frequency 43
44
T EST R ESULTS Vibration Test Result Test progress Anemometer structure with sealed air: yes Anemometer structure with sealed liquid: no Calorimetric structure: no 44
45
T EST R ESULTS Sensor Response to Vibration Test mode: bias current 10nA Power consumption: 45
46
T EST R ESULTS Sensor Response Under Different Heating Current Frequency fixed to 2Hz Input current: 10pA to 0.1mA Response defined by 46 In tests, driven current was set to 10nA
47
T EST R ESULTS Acceleration Responsivity More sensitive to small acceleration Linear – log relationship Saturation limit > 1.2m/s 2 47
48
T EST R ESULTS Phase Delay Test 180 ° phase delay Response time not detectable 48 Dual channel Sourcemeter Dual channel Sourcemeter velocity Laser Vibrometer Sensor voltage output a=dv/dt R=vi
49
CONCLUSION Introduction Literature Review Sensor Design Test Setup Test Results 49
50
C ONCLUSION Conclusion – Work Done Working principle, structures and performances of currently developed thermal convective accelerometers were reviewed. CNT-based thermal convective accelerometers were designed and prototyped. Testing facilities were purchased and set up. Prototypes were tested under inclination and vibration. 50
51
C ONCLUSION Conclusion - Results Calorimetric structure with sealed ethanol can sense static inclination Anemometer structure with sealed air can sense vibration Contributions First CNT based motion sensor First CNT based thermal convective motion sensor Smallest power consumption * No solid proof mass, easy to fabricate More understanding about heating and sensing effect of CNTs 51 * Considering the sensing block only
52
52
53
SUPPORTING MATERIALS 53
54
S UPPLEMENTS Improving Frequency Test Range 54 sourcemeter sampling limit vibration exciter working range 1Hz10Hz100Hz1000Hz0.1Hz0.001Hz New circuit sampling limit 1Hz10Hz100Hz1000Hz0.1Hz0.001Hz vibration excitercrank-link mechanism
55
S UPPLEMENTS Crank-link Mechanism 55
56
S UPPLEMENTS Sensor Read-out Circuit 56
57
S UPPLEMENTS Future work – Sensor Charactorizaiton Step response Bandwidth (frequency response) Saturation (requires higher acceleration peak) 57
58
Future Work – Sensor Design Size of sealed chamber Noise level Optimized input current (sensitivity and noise) Properties of convection medium (liquid, air, pressure) Compensation of environmental temperature change Feedback control 58
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.