Presentation is loading. Please wait.

Presentation is loading. Please wait.

Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 1 Scaffolding For Residential.

Similar presentations


Presentation on theme: "Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 1 Scaffolding For Residential."— Presentation transcript:

1 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 1 Scaffolding For Residential Construction Susan B. Harwood Grant Training Program

2 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 2 Disclaimer/Usage Notes Photos shown in this presentation may depict situations that are not in compliance with applicable OSHA requirements. It is not the intent of the content developers to provide compliance- based training in this presentation, the intent is more to address hazard awareness in the residential construction industry, and to recognize the overlapping hazards present in many construction workplaces. It should NOT be assumed that the suggestions, comments, or recommendations contained herein constitute a thorough review of the applicable standards, nor should discussion of “issues” or “concerns” be construed as a prioritization of hazards or possible controls. Where opinions (“best practices”) have been expressed, it is important to remember that safety issues in general and construction jobsites specifically will require a great deal of site- or hazard-specificity – a “one size fits all” approach is not recommended, nor will it likely be very effective.

3 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 3 Disclaimer/Usage Notes No representation is made as to the thoroughness of the presentation, nor to the exact methods of remediation to be taken. It is understood that site conditions vary constantly, and that the developers of this content cannot be held responsible for safety problems they did not address or could not anticipate, nor those which have been discussed herein or during physical presentation. It is the responsibility of the employer, its subcontractors, and its employees to comply with all pertinent rules and regulations in the jurisdiction in which they work. Copies of all OSHA regulations are available from your local OSHA office, and many pertinent regulations and supporting documents have been provided with this presentation in electronic or printed format. This presentation is intended to discuss Federal Regulations only - your individual State requirements may be more stringent. It is assumed that individuals using this presentation or content to augment their training programs will be “qualified” to do so, and that said presenters will be otherwise prepared to answer questions, solve problems, and discuss issues with their audiences.

4 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 4 Disclaimer/Usage Notes Areas of particular concern (or especially suited to discussion) have additionally been marked with a ? symbol throughout the program…as a presenter, you should be prepared to discuss all of the potential issues/concerns, or problems inherent in those photos particularly.

5 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 5 General Requirements All scaffolds must be able to support 4 times the intended load Scaffolds must be properly designed and constructed Each working level must be fully planked Minimum scaffold width 18 inches –Except ladder jack and pump jack scaffolds –Minimum of 12 inches

6 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 6

7 7

8 8

9 9 Scaffolds can be no more than 14” from the work surface –Except for plaster’s scaffolds – 18” –And outriggers 3” If more space, guardrails required

10 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 10 Planking Planks must extend 6” over support Overlaps must be 12” –6” each side of support Split planks must be removed Only materials intended for scaffold planks can be used

11 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 11

12 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 12

13 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 13

14 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 14

15 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 15

16 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 16 Bracing & Tie Backs Scaffolds must be braced and/or tied back to support scaffolds Metal bracing must be used with pump jacks

17 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 17

18 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 18

19 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 19

20 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 20

21 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 21 Support Base plates must always be used Mud sills required unless on concrete

22 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 22

23 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 23

24 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 24 Support No brick, block or barrels to support scaffold or platforms Equipment cannot be used to support scaffolds

25 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 25

26 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 26

27 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 27

28 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 28

29 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 29

30 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 30

31 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 31 Access to Scaffolds Ladders must be used if first step is 24” or more Brick mason’s frames not acceptable to climb Maximum spacing between rungs 16 ¾” Minimum rung length 8” Uniformly spaced No climbing X-bracing

32 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 32

33 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 33 Inspection Daily inspections required before use Damaged items must be replaced

34 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 34 Proper Use No barrels, boxes or ladders on top of scaffolds

35 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 35

36 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 36

37 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 37 Fall Protection Fall protection required at 10’ –Guardrails with midrails, or –Personal Fall Arrest –X-bracing can be toprail or midrail, but not both 38-48” for toprail 20-30” for midrail Ends of brace 48” or less

38 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 38

39 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 39

40 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 40

41 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 41 Falling Object Protection Must always wear a hard hat on a scaffold To protect people below –Toeboards, –Canopies,or –Barricading the area must be provided

42 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 42

43 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 43

44 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 44 Special Requirements Job-made ladders not allowed for scaffold support Scaffold frames must be pinned together Forklift platforms must be factory built or equal

45 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 45

46 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 46

47 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 47

48 Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 48 Questions? Answers to additional questions can be found in the following source materials –29 CFR 1926 Construction Regulations –Scaffold Industry Association –ANSI A92 Series for scaffolding


Download ppt "Developed under an OSHA Susan B. Harwood Grant, #46F4-HT01, by the Associated Builders and Contractors-Central Texas Chapter 1 Scaffolding For Residential."

Similar presentations


Ads by Google