Download presentation
1
FORD FIELD BOOSTER Aqua~FloPacTM
Flo-Pak, Inc. a business unit of Patterson Pump Company FORD FIELD BOOSTER Derek J. Guminik Energy Solutions Associate
2
Aqua~FloPac Supply The Demand
AquaFloControl™ Plumbing Systems offer proven quality and reliability when it comes to delivering clean water at controlled volume and pressure to high-density residential, light industrial, independent water systems, dormitories and office buildings. These booster pumping systems eliminate the need for job-by-job system engineering involving individual pumps, accessories and controls. They are an excellent, cost-effective technical solution for supplying high demands. Many configurations are available, along with the technical support to implement custom installations for complete customer satisfaction.
3
Aqua~FloPac UL-QCZJ listed on the Panels UL-QRNZ listed on Enclosures
NSF-61 Annex G Lead contaminates ETL- CAT. 225 UL/ETL-508 Electrical Standards Seismic Calculations available
4
Systems for Low Flow / High Head Models (up to 555’ TDH)
Aqua~FloPac Variable Speed Models NSF-61 Complaint Patterson End Suction Pumps Systems for Low Flow / High Head Models (up to 555’ TDH)
5
Aqua~FloPac Heart of Our System Schneider LCD Touch-Screen Controller
Operator Interfaces with all BAS Systems Easier Start-Up Easier System Adjustments by maintenance Housed in NEMA I2 (other Ratings or Request Enclosures)
6
Different Configuration to Solve Our Customer’s Requirements
Aqua~FloPac Different Configuration to Solve Our Customer’s Requirements Vertical Mount Unit
7
Split Base option to fit through existing 36” door.
Aqua~FloPac Split Base option to fit through existing 36” door.
8
Maximum Performance For Maximum Efficiency
Introducing our TDH+ Maximum Performance For Maximum Efficiency Model TDH is designed and engineered for maximum performance and energy efficiency with budget restrains in mind, and offers: vertical multi-stage pumps higher discharging pressures than the standard end suction pump a smaller footprint both constant and variable speed Changeable orientation of headers NEMA 1 (others upon request)
9
Selection Data and Pump Curves Vertical Multi-Stage Pumps
TDH+ Pump Selection Data and Pump Curves Vertical Multi-Stage Pumps
10
Aqua~FloPac Selection Program @ www.pattersonpumps.com
Click on (Red Pump) Pump Finder Click on (Green Letter) AFP Selection Program Click on Register for First Time Users and fill in registration information, a confirmation will be sent.
11
Aqua~FloPac Every Unit is Flow tested and run to actual customer’s conditions at factory before shipment. All Set Points set at the factory but can be easily adjusted in field All units are UL-QCZJ listed; ISO 9001, ISO as well as Six Sigma Quality reviewed. NSF-61 compliant. VFD’s mounted in Control Panel for added protection and increase of life span. Touch Screen Controller for easy operation and maintenance adjustments in Field. Single source responsibility achieved by Patterson making pumps. Factory Trained Field Technician in every State for Support thru-out USA. This Aqua-FloPac package VFD package serves a 3-story office building This TDH Model meets the constant demands of a university dorm.
12
Duplex with Tank on Skid
13
Quadplex Aqua~FloPac Booster
14
Quadplex TDH+ Booster
15
Simplex TDH+
16
Simplex Aqua~FloPac
17
Vertical Turbine Booster
18
Vertical Turbine Booster
19
Fiberglass Enclosure with Booster
20
Fiberglass Enclosure
21
Aqua~FloPacTM Trust the Company that is not only builds the Plumbing Booster but builds the Pump as well.
22
Kansas City Stadium Boosters
23
Arrowhead Stadium
24
Kauffman Stadium
25
Dallas, TX Stadium
26
Cowboys Stadium-2 Boosters
27
GA. Dome- ATL
28
UGA Sanford Stadium
32
UGA Sanford Stadium
33
Modbus Protocol
34
· Fabricated Welded Steel Base Assembly
· ButterFly Shutoff Valve on Each Pump Suction and Discharge · Suction Header Pressure Gauge · Discharge Header Pressure Gauge · Low Suction Pressure Switch, Time Delay With Auto Reset · Non-Electric Thermal Protection Valve for Each Pump · Control Panel, UL508A/ETL Listed · Low Discharge Pressure Alarm, Time Delay With Auto Reset · High Discharge Pressure Shutdown Alarm, Time Delay With Auto Reset · Automatic Alternation of Pumps (Duty Cycle Type with 24 Hour Override) · Common Alarm Dry Relay Contacts, 1-NO (A-Form) · Real-Time Clock for System Enable/Disable · Operator Interface on Control Panel Door · Timers & Pressure Values Adjustable via Operator Interface · Main Power Disconnect 400 Amp · Single Point Power Connection · PLC Controller · HOA Switch for Each Pump in Operator Interface · Run Light for Each Pump in Operator Interface · Control Power Transformer · Lead Pump Shut Down · Terminal Strip · Digital Pressure Display · Factory Startup Included · ** NSF61 · Graphic Operator Interface Terminal · Discharge Pressure Transducer Cloud operating system OPTION A: CURRENTLY UNDER NSF APPROVAL AVAIALBLE IN APPROX 90 DAYS Model: CUSTOM TAP-XX-7575-CC V 3 Phase 60HZ VARIABLE SPEED Triplex System Total System Flow: 3600 GPM System Discharge: 65 PSI Suction Pressure between PSI System Boost: 63 PSI Pump # GPM 150 TDH 75 HP 33% of Sys Flow Model: E4JA13A-CC Pump # GPM 150 TDH 75 HP 33% of Sys Flow Model: E4JA13A-CC Pump # GPM 150 TDH 75 HP 33% of Sys Flow Model: E4JA13A-CC
35
· Fabricated Welded Steel Base Assembly
· ButterFly Shutoff Valve on Each Pump Suction and Discharge · Suction Header Pressure Gauge · Discharge Header Pressure Gauge · Low Suction Pressure Switch, Time Delay With Auto Reset · Non-Electric Thermal Protection Valve for Each Pump · Control Panel, UL508A/ETL Listed · Low Discharge Pressure Alarm, Time Delay With Auto Reset · High Discharge Pressure Shutdown Alarm, Time Delay With Auto Reset · Automatic Alternation of Pumps (Duty Cycle Type with 24 Hour Override) · Common Alarm Dry Relay Contacts, 1-NO (A-Form) · Real-Time Clock for System Enable/Disable · Operator Interface on Control Panel Door · Timers & Pressure Values Adjustable via Operator Interface · Main Power Disconnect 400 Amp · Single Point Power Connection · PLC Controller · HOA Switch for Each Pump in Operator Interface · Run Light for Each Pump in Operator Interface · Control Power Transformer · Lead Pump Shut Down · Terminal Strip · Digital Pressure Display · Factory Startup Included · ** NSF61 · Graphic Operator Interface Terminal · Discharge Pressure Transducer Cloud operating system OPTION B: Model: CUSTOM TAP-XX-5050-CC V 3 Phase 60HZ VARIABLE SPEED FIVE (5) PUMP System Total System Flow: 3600 GPM System Discharge: 65 PSI Suction Pressure between PSI System Boost: 63 PSI Pump #1, #2, #3, #4, #5 750 GPM 150 TDH 50 HP 33% of Sys Flow Model: CR 8 WEEKS after approved submittals received