1
ET 01.06.2002 CMS detector resolution zCMS Silicon Strip Tracker zCMS Silicon Strip Detector Resolution zHIP Silicon Beam Telescope
2
ET 01.06.2002 CMS Silicon Strip Tracker zDiameter 2.4 m, Length 5.6 m zTracker Inner Barrel (TIB), Tracker Inner Disks (TID), Tracker Outer Barrel (TOB), Tracker End Caps (TEC) zTemperature -10 C 0.1 1.5 2.5 20 cm 120 cm 0 2.8 m
3
ET 01.06.2002 CMS Silicon Strip Detectors z n-type FZ Silicon wafers, p+ strips, AC coupled, single-sided z Strip width: strip/pitch ~ 0.25, strip length typically 12.5 cm Wafer thickness m Resistivity k cm Pitch @ barrel detectors m Pitch @ disk detectors m Inner Tracker3201.5–3.080 or 12081-112 … 124-158 Outer Tracker5003.5–6.0122 or 183126-143 … 186-205
4
ET 01.06.2002 Needs for Detector Resolution zObjective of CMS and Tracker: to detect signatures of new physics at LHC zMethod: by identifying and precisely measuring leptons, photons and jets zTools: Tracking and Vertex reconstruction within a strong 4 T magnetic field zTracker measurements are combined with track segments reconstructed in the outer muon system -> to further extend the region over which a precise MUON momentum measurement can be performed (-> alignment)
5
ET 01.06.2002 Requirements for the Detector Resolution zCMS Tracker is designed to ensure high quality momentum resolution: y momentum resolution better than p T /p T = 0.15*p T (in TeV/c), all 2.5 zHit resolution requirements for successful track reconstruction: x around 15 um @ Tracker inner radius x around 40 um @ Tracker outer radius zThis means: x Pixel: barrel 10 –15 um endcaps 15 –20 um x TIB: better than 20 um for shorter pitches approaching (pitch/neliojuuri12) for larger pitches x TOB:pitch 140 um -> resolution better than 40 um pitch 210 um -> resolution better than 60 um (for hight pT tracks)
6
ET 01.06.2002 Studies of Single Track Performance zStudy of single hit quality for several pitch values zStudy of single muon tracks of several pT values in all silicon tracker z-> evaluation of the precision of the track reconstruction performance zAccumulation of 500 tracks for statistics zCMSIM & GEANT
7
ET 01.06.2002 Test beam results of the Detector Resolution zBarrel strip detector: 50 um pitch, 12.5 cm length -> hit resolution 11 um zDouble-sided detectors: pitch 100 um, stereo angle 100 mrad -> resolution 34 um orthogonal to stereo strips and 320 um in the stereo coordinate zWedge detector: 6.25 cm strips, 38-50 um pitch -> resolution 7 um zThe dependence of the resolution on the signal-to-noise-ratio, bias voltage and incidence angle is weak
8
ET 01.06.2002 HIP Silicon Beam Telescope zOur ”mini-Tracker” z8 layers of Silicon detectors & adequate read-out electronics and DAQ zPitch 55 um zSpatial resolution obtained in summer 2001 beam tests: 10 m zSummer 2002: our own rad-hard Cz detectors & stereo angle detector