Presentation is loading. Please wait.

Presentation is loading. Please wait.

Synchronization system for CLIC crab cavities Amos Dexter, Ben Woolley, Igor Syratchev. LCWS12, UTA October 2012.

Similar presentations


Presentation on theme: "Synchronization system for CLIC crab cavities Amos Dexter, Ben Woolley, Igor Syratchev. LCWS12, UTA October 2012."— Presentation transcript:

1 Synchronization system for CLIC crab cavities Amos Dexter, Ben Woolley, Igor Syratchev. LCWS12, UTA October 2012

2 Crab cavity action 2 travelling wave crab cavity @12GHz quadrupoles Detector 20 milli-rad crossing 40.6 m Bunches pass through deflecting cavities phased to give zero kick for bunch centres A deflecting cavity phased in this way is called a crab cavity For a bunch with length The crab cavity kicks the bunch front to start rotating away from the other beamline The crab cavity kicks the bunch rear to start rotating towards the other beamline Perfect alignment of bunches occurs only at the IP Without a correctly functioning crab cavity CLIC looses 90% of its luminosity The crab cavity system cannot be compromised.

3 Synchronisation Requirement Cavity to Cavity Phase synchronisation requirement Target max. luminosity loss fraction S f (GHz)  x (nm)  c (rads)  rms (deg)  t (fs) Pulse Length (  s) 0.9812.0450.0200.01884.40.156 Estimate RF to beam synchronisation ~ 100 fs (0.43 degrees)

4 RF Distribution 1: A single klystron with high level RF distribution to the two cavities. Klystron phase jitter gets sent to both cavities for identical path length. Δφ=0. Will require RF path lengths to be stabilised to within 1 micron over 40m. 2: A klystron for each cavity synchronised using LLRF/optical distribution. Femtosecond level stabilized optical distribution systems have been demonstrated (XFELs). Requires klystron output with integrated phase jitter <4.4 fs.

5 Integration Use over-moded waveguide from klystron to the tee ~35m of waveguide from the Tee to the cavities, 20.3m from cavities to IP

6 Waveguide Choice 6 Waveguide type 35 meters COPPER Expansion = 17 ppm/K ModeTransmissionTiming error/0.3°C Width Timing error/0.3°C length N o of modes WR90(22.86x10.16mm)TE1045.4%210.5 fs498.9 fs1 Large Rectangular (25x14.5mm) TE1057.9%189.3 fs507.8 fs2 Cylindrical r =18mmTE0166.9%804.9 fs315.9 fs7 Cylindrical r =25mmTE0190.4%279.6 fs471.4 fs17 Copper coated extra pure INVAR 35 meters Expansion = 0.65 ppm/K ModeTransmissionTiming error/0.3°C Width Timing error/0.3°C length N o of modes WR90(22.86x10.16mm)TE1045.4%8.13 fs19.04 fs1 Large Rectangular (25x14.5mm) TE1057.9%6.57 fs19.69 fs2 Cylindrical r =18mmTE0166.9%30.8 fs12.1 fs7 Cylindrical r =25mmTE0190.4%10.7 fs18.02 fs17 Rectangular invar is the best choice as it offers much better temperature stability-> Expands 2.3 microns for 35 m of waveguide per 0.1 °C.

7 CLIC LLRF Timing Booster Linac 561 m 2.2 to 9.0 GeV IP Bunch timing pick-ups Klystron LLRF Bunch timing pick-ups Drive beams 12 GHz Chicane stretching PETS 0.05 km 2.75 km 21 km Crab cavity electrons positrons compressor linac Synchronisation to main beam after booster linac. For a 21 km linac we have 140 ms between bunches leaving the booster and arriving at the crab cavities. 2 GHz bunch rep LLRF Crab bunch timing pickups could be 2.75 km away from LLRF

8 RF path length measurement 48MW 200ns pulsed 11.994 GHz Klystron repetition 50Hz Vector modulation Control Phase Shifter 12 GHz Oscillator Main beam outward pick up From oscillator Phase shifter trombone (High power joint has been tested at SLAC) Magic Tee Waveguide path length phase and amplitude measurement and control 4kW 5  s pulsed 11.8 GHz Klystron repetition 5kHz LLRF Phase shifter trombone LLRF Cavity coupler 0dB or -40dB Expansion joint Single moded copper plated Invar waveguide losses over 35m ~ 3dB -30 dB coupler Forward power main pulse 12 MW Reflected power main pulse ~ 600 W Reflected power main pulse ~ 500 W Waveguide from high power Klystron to magic tee can be over moded Expansion joint RF path length is continuously measured and adjusted

9 LLRF Hardware Layout Fast phase measurements during the pulse (20-30 ns). Full scale linear phase measurements to centre mixers and for calibration. High accuracy differential phase measurements of RF path length difference (5 μs, 5 kHz). DSP control of phase shifters. Linear Phase Detector DSP ADC Magic Tee To Cavity Wilkinson splitters -30 dB coupler DBM 10.7GHz Oscillator -30 dB coupler Piezoelectric Phase Shifter Piezoelectric phase shifter DAC1 Amp + LPF LPF Amp Power Meter To DSP DAC2 From DAC2 To Phase Shifter Calibration Stage

10 Analogue Board Development Front end electronics to enable phase to be measure during the short pulses to an accuracy of 2 milli-degrees has been prototyped and dedicated boards are being developed. PLL controller MCU 10.7 GHz VCO Digital phase detector DBMs Power Meters Wilkinson splitter Inputs 400 ns span: RMS: 1.8 mdeg Pk-Pk: 8.5 mdeg 90 s span: Drift rate : 8.7 mdeg/10s Total drift: 80 mdeg

11 Waveguide Stability Experiments Phase Measurement Electronics Amplifier Long Waveguide section Waveguide Splitter Clamps Loud-speaker 12 GHz source Coax Cable 1 kHz sine wave from 1 W RMS speaker detected as a 25 milli-degree pk-pk phase variation.

12 ADC+DSP scheme Use DSP as opposed to FPGA for increased flexibility, due to low duty cycle DSP is fast enough. Sixteen, 16-bit D flip-flops store data coming from a single ADC controlled by the ADC’s clock. The system then uses pulses from the DSP to shift the data once it has been read and processed. 12 ADCBuffer1DSP ADC clock Buffer16 Signal from phase measurement system ADC clock signals DSP clock signals

13 Sampling Boards System has been manufactured and implemented with 13 noise free bits. Multiplexer is available for increased I/O. 13 Buffer board ADC DSP

14 Future Comprehensive investigation into phase stability of X-band klystrons using the 12 GHz stand alone test stand at CERN. (50MW XL5, Scandinova Modulator) Development of feed-forward and/or feedback system to stabilise the klystron’s output. Continued development of electronics to obtain stand alone phase measurement/correction system. Design/procurement of the waveguide components needed. Demonstration RF distribution system, with phase stability measurements. Stand alone or parasitic on CTF-3 dog leg? Measure phase noise across the prototype cavity during a high power test. 14

15 Summary Phase synchronisation (4.4 fs) 1)Same klystron drives both cavities, stabilized waveguide 2)Separate, stabilised klystrons for each cavity. Klystron phase and amplitude control Passive + active feed forward during 156 ns bunch train Phase measurement Calibration stage and DBM. Down conversion to ~ 1 GHz, with digital phase detection. Waveguide phase correction DSP correction system with waveguide trombone phase shifters. (Choke mode flange). Requirements for synchronisation have been established Synchronisation scheme(s) to meet specification has been formulated Prototyping of electronics for necessary phase measurements/correction Co-ordinated effort on the synchronisation scheme with CERN Future high power experiments outlined

16 Extra Slides

17 Waveguide Stability Model Use ANSYS to find “dangerous” modes of vibration for a 1 m length of waveguide fixed at both ends. Fundamental mode 65.4 Hz

18 Planned CLIC crab high power tests Test 1: Middle Cell Testing – Low field coupler, symmetrical cells. Develop UK manufacturing. Test 2: Coupler and cavity test – Final coupler design, polarised cells, no dampers. Made with CERN to use proven techniques. Test 3: Damped Cell Testing – Full system prototype Travelling wave 11.9942 GHz phase advance 2  /3 TM110h mode Input power ~ 14 MW


Download ppt "Synchronization system for CLIC crab cavities Amos Dexter, Ben Woolley, Igor Syratchev. LCWS12, UTA October 2012."

Similar presentations


Ads by Google