Download presentation
Presentation is loading. Please wait.
Published byDamian Long Modified over 9 years ago
1
HD group LEPS RCNP C. Morisaki
2
① Development of NMR measurement system for the polarized HD target ② Development of single crystal HD target
3
In the case of proton in HD, ~ 95% of polarization will be expected at 17 Tesla and 10mK. How to measure ? “ the NMR method ”
4
Check the NMR spectra of LH 2 with use an one of the NMR system, called “single coil method”.
5
signal ∝ exp( iθ ) ・ Single coil method uses one coil takes both transmitter and receiver coil. ・ Cancellation circuit for keeping away signals which enter in Lock-in Amp at direct without entering in the coil. ・ single coil method
6
cylindrical sample cell (Stycact) NMR coil covers the whole region The H 2 consisted in the cell was liquefied at 17K. The magnetic field was swept from 0.405T to 0.41T. The signal frequency was fixed 17MHz.
7
Spectra of LH 2 with single coil method ※ Resonance frequency of H 2 is about 17MHz at field of 0.407Tesla. 0.4050.4070.41 magnetic field (T) magnitude of signal (V) Im part Re part
8
The longitudinal relaxation time T 1 of NMR is related to the intensity of the signal and the transverse relaxation time T 2 is related to the line width. T 1 : It is time from after stop a 90°pulse to system backs a equilibrium to vertical. apply 90°pulse and stop T 2 : It is time from after stop a 90°pulse to system backs a equilibrium to horizontal. apply 90°pulse and stop
9
Polarization P depends on exp(-t/T 1 ). t : time Signal depends on dP/dt = (- 1 /T 1 ) ・ exp(-t/T 1 ). The shorter T 1 is, the higher peak becomes. The polarization will be obtained by integration of the peak. At these points, We can think that 2 peaks are consisted by 2 sorts of Hydrogen-state which take a difference state respectively.
10
LH 2 in a cell → The sharp peak came from LH 2. { T 1 :short → Hydrogen included in Stycast brought about the broad peak. { T 1 :long empty cell (Stycast) ← background That is ・・・ Comparison between spectra of LH2 and non-LH2
11
Make a new cell made of non-Hydrogen material in order to exclude the background. exam) Kel-F Change the NMR system from single coil to crossed coil method has a high accuracy. Calculate the polarization by integration of a peak area after excluding the background. single LH 2 → crossed LH 2 → crossed HD StycastKel-F
12
・ crossed coil method ・ Coils lie orthogonally each other. → There is no influence from magnetic field made by signals each other. ・ Coils are separated each other. → It is not necessary to use a cancel circuit.
13
at inner of dilution refrigerator (DR) low thermal conductivity → ~ 10 W/K ・ m high thermal conductivity → about ~ 10 3 W/K ・ m But ・・・ 6m K a few ten mK 6m K below 10mK
14
These aluminum wires will bring the background at LEPS experiments. ( Of course, there is few problem at LEPS experiments, if we take a difference between a date of HD which include the aluminum and a date of only aluminum.) high thermal conductivity without aluminum wires “ Single Crystal -HD target”
15
Single Crystal is a crystal which has hexagonal close-packed structure. ・ Normal crystal ・ Single Crystal low density → low thermal conductivity high density → high thermal conductivity = HD
16
Normal crystallization ① only cool down from 300K to 10mK Single crystal ① cool down to around 10K which is temperature that the HD starts crystallization ② make a difference of temperature in between a bottom of the cell and a top of the cell to use heaters, cool down at a fair low speed, insert the HD in the cell slowly, crystallize the HD from the bottom of the cell
17
A conductivity measurement on SC-HD was undertaken with LHe cryostat.
18
After crystallization, the conductivity measurement was carried out. result This is the world first report on thermal conductivity of the single crystal HD. Heat flow // z-axis
19
The improved measurement will be performed soon. The conductivity will be further enhanced with ( ⅰ ) higher HD purity (>99.9%) prepare with a distillation apparatus to reduce the impurity contribution; by about 100 times, and ( ⅱ ) heat flow perpendicular to the z-axis of the single crystal; by about 50 times.
20
(250 mK) (250 mK) ? γ p γ p K-K- unobservableobservable ・ a new one K+K+ K+K+ K-K- dipole
21
Make a sample nose made of SUS, thin layers made of cupper Play a cooling test of sample nose to 250mK at RCNP
22
Fin