Failure After Fixation with Flexible IM Nail in Adolescent Femur Shaft Fracture Inje University, Ilsan Paik Hospital Suk Kyu Choo MD.

Similar presentations


Presentation on theme: "Failure After Fixation with Flexible IM Nail in Adolescent Femur Shaft Fracture Inje University, Ilsan Paik Hospital Suk Kyu Choo MD."— Presentation transcript:

1 Failure After Fixation with Flexible IM Nail in Adolescent Femur Shaft Fracture Inje University, Ilsan Paik Hospital Suk Kyu Choo MD

2 Pediatric Femur Shaft Fracture ► Traction and hip spica cast ► Plate and Screws ► External Fixation ► Flexible IM nail

3 Flexible IM Nail ► Elastic titanium nail by Metazear and Lascombes(Nancy Nail) ► Easy technique ► Less invasive ► Early weight bearing, ROM ex. ► No physeal injury, or AVN(Interlocking nail), ► NO refracture(Plate and screws, Ex-Fix) ► Less LLD(?) ► High union rate ► Bar-On et al, JBJS, 1997 ► Oh et al, J Korean Fracture Soc., 2002 ► Yoon et al, J Korean Fracture Soc., 2003 ► Wenger, Rang’s Children’s Fractures, 2005

4 Adolescent Femur Shaft Fracture ► Interlocking IM nail  Trochanteric entry to avoid AVN ► Plate and screws ► Flexible IM nails

5 Flexible IM Nail ► Is it strong enough for heavier adolescents? ► Can it control rotation and angulation in adolescents?

6 Case 1 ► 14 yrs old girl ► Femur shaft fracture with butterfly fragment

7 Case 1

8 Case 2 ► 16 yrs old girl ► Lt femur shaft fracture with butterfly fragment

9 Case 2 ► CR and IF with Flexible IM nail ► LLS and Thigh cuff brace

10 Case 2 ► Thigh cuff brace  angulation ► Required reop with Ex-Fix.

11 Case 3 ► 19 years old girl with femur shaft fracture ► Narrow femoral canal

12 Case 3 ► CR and IF with flexible IM nail ► Anterior bowing and nonunion after 8 month ► Converted to Interlocking nail

13 Femoral Shaft Fractures in Adolescents AuthorsAgeCasesComplicationsAftercare Mann DC 9-1515nonecrutches Ender Nail Fein LH 10-1623 1 angulation crutches Ender Nail Flynn JM 4-1658 1 varus 6 mild malalignment VariableTitaniumNail Yoon YH 4-1128 1 fix. Failure 1 infection BraceTitanium Oh CW 4-1019- LLS 2 wks

14 Femoral Shaft Fractures in Adolescents ► Fixation should be  Stable enough to achieve union  Early motion, early ambulation  Less complications  Easy to apply

15 Titanium Flexible IM nail ► High union rate ► Early motion, ambulation ► No physeal injury vascular injury ► Less invasive ► Easy technique

16 Titanium Flexible IM nail ► Less stable than  Interlocking nails  Ender Nail(Stainless steel nail) ► Good result in children’s fracture ► Special considerations in applying to larger adolescents femur fractures